Heat transfer enhancement in solar air heater with V-shaped perforated baffles

This experimental study, investigates the heat transfer and friction characteristics in a rectangular duct having its one broad wall heated and roughened with periodic V-down shaped perforated baffles. This work covered a range of Reynolds number (Re) 3800–19 000, open area ratio (β) 12%–44%, relative hole position (l/e) 0.429–0.571 for the fixed values of relative baffle height (e/H) 0.4, relative roughness pitch (p/e) 5, and angle of attack of 60°. The effects of relative hole position on Nusselt number and friction factor have been discussed and results compared under similar flow and boundary conditions to investigate the enhancement in Nusselt number and friction factor. The maximum enhancement in Nusselt number and friction factor has been obtained at an open area ratio of 12% and is of the order of 2.2 and 5.2 times of that of smooth duct, respectively. Thermohydraulic performance of solar air heater has been found to be substantially improved by the application such perforated baffles.

[1]  Prashanta Dutta,et al.  Internal cooling augmentation in rectangular channel using two inclined baffles , 2005 .

[2]  S. C. Solanki,et al.  Heat transfer and friction in solar air heater duct with V-shaped rib roughness on absorber plate , 2002 .

[3]  S. J. Kline,et al.  Describing Uncertainties in Single-Sample Experiments , 1953 .

[4]  R. Karwa EXPERIMENTAL STUDIES OF AUGMENTED HEAT TRANSFER AND FRICTION IN ASYMMETRICALLY HEATED RECTANGULAR DUCTS WITH RIBS ON THE HEATED WALL IN TRANSVERSE, INCLINED, V-CONTINUOUS AND V-DISCRETE PATTERN , 2003 .

[5]  Sandip Dutta,et al.  Effect of baffle size, perforation, and orientation on internal heat transfer enhancement , 1998 .

[6]  Rajendra Karwa,et al.  Heat transfer and friction in an asymmetrically heated rectangular duct with half and fully perforated baffles at different pitches , 2009 .

[7]  R. Karwa,et al.  Experimental Study of the Effects of Rib Angle and Discretization on Heat Transfer and Friction in an Asymmetrically Heated Rectangular Duct , 2005 .

[8]  Je-Chin Han,et al.  Thermal Performance of Angled, V-Shaped, and W-Shaped Rib Turbulators in Rotating Rectangular Cooling Channels (AR=4:1) , 2004 .

[9]  Je-Chin Han,et al.  High performance heat transfer ducts with parallel broken and V-shaped broken ribs , 1992 .

[10]  S. C. Solanki,et al.  Heat transfer coefficient and friction factor correlations for rectangular solar air heater duct having transverse wedge shaped rib roughness on the absorber plate , 2002 .

[11]  Jenn-Jiang Hwang,et al.  Effect of fence thickness on pressure drop and heat transfer in a perforated-fenced channel , 1998 .

[12]  J. Saini,et al.  Experimental investigation on heat-transfer enhancement due to a gap in an inclined continuous rib arrangement in a rectangular duct of solar air heater , 2008 .

[13]  J. S. Saini,et al.  A review of turbulence promoters used in solar thermal systems , 2012 .

[14]  R. T. Kukreja,et al.  Local heat/mass transfer distribution in a square channel with full and V-shaped ribs , 1993 .

[15]  Sheng-Chung Tzeng,et al.  Experimental study of fluid flow and heat transfer characteristics in the square channel with a perforation baffle , 2008 .

[16]  Mehmet Yilmaz,et al.  Heat-transfer enhancement in a channel flow with perforated rectangular blocks , 2001 .

[17]  T. Liou,et al.  Turbulent heat and fluid flow in a passage disturbed by detached perforated ribs of different heights , 1998 .

[18]  Chu-Wei Lin Experimental study of thermal behaviors in a rectangular channel with baffle of pores , 2006 .

[19]  B. Sundén,et al.  Heat transfer and pressure drop measurements in rib-roughened rectangular ducts , 2001 .

[20]  C. P. Lee,et al.  Augmented Heat Transfer in Square Channels With Parallel, Crossed, and V-Shaped Angled Ribs , 1991 .

[21]  Jenn-Jiang Hwang,et al.  HEAT-TRANSFER IN A RECTANGULAR CHANNEL WITH PERFORATED TURBULENCE PROMOTERS USING HOLOGRAPHIC-INTERFEROMETRY MEASUREMENT , 1995 .

[22]  Rajendra Karwa,et al.  Experimental study of heat transfer enhancement in an asymmetrically heated rectangular duct with perforated baffles , 2005 .

[23]  Sei-Young Lee,et al.  The Effects of Gap Position in Discrete Ribs on Local Heat/Mass Transfer in a Square Duct , 2003 .

[24]  B. Sundén,et al.  Heat transfer distribution in rectangular ducts with V-shaped ribs , 2001 .

[25]  N. K. Anand,et al.  Use of porous baffles to enhance heat transfer in a rectangular channel , 2003 .

[26]  Je-Chin Han,et al.  Heat Transfer Characteristics of Turbulent Flow in a Square Channel With Angled Discrete Ribs , 1991 .