A Multiscale Optimization Approach to Detect Exudates in the Macula

Pathologies that occur on or near the fovea, such as clinically significant macular edema (CSME), represent high risk for vision loss. The presence of exudates, lipid residues of serous leakage from damaged capillaries, has been associated with CSME, in particular if they are located one optic disc-diameter away from the fovea. In this paper, we present an automatic system to detect exudates in the macula. Our approach uses optimal thresholding of instantaneous amplitude (IA) components that are extracted from multiple frequency scales to generate candidate exudate regions. For each candidate region, we extract color, shape, and texture features that are used for classification. Classification is performed using partial least squares (PLS). We tested the performance of the system on two different databases of 652 and 400 images. The system achieved an area under the receiver operator characteristic curve (AUC) of 0.96 for the combination of both databases and an AUC of 0.97 for each of them when they were evaluated independently.

[1]  B. Thomas,et al.  Automated identification of diabetic retinal exudates in digital colour images , 2003, The British journal of ophthalmology.

[2]  Asoke K. Nandi,et al.  Novel and adaptive contribution of the red channel in pre-processing of colour fundus images , 2007, J. Frankl. Inst..

[3]  J. Olson,et al.  Automated grading for diabetic retinopathy: a large-scale audit using arbitration by clinical experts , 2010, British Journal of Ophthalmology.

[4]  Wilhelm Burger,et al.  Digital Image Processing - An Algorithmic Introduction using Java , 2008, Texts in Computer Science.

[5]  Pascale Massin,et al.  A contribution of image processing to the diagnosis of diabetic retinopathy-detection of exudates in color fundus images of the human retina , 2002, IEEE Transactions on Medical Imaging.

[6]  Victor Murray,et al.  Automatic detection of diabetic retinopathy and age-related macular degeneration in digital fundus images. , 2011, Investigative ophthalmology & visual science.

[7]  J. Kanski Clinical Ophthalmology: A Systematic Approach , 1989 .

[8]  J. Olson,et al.  Automated detection of exudates for diabetic retinopathy screening , 2007, Physics in medicine and biology.

[9]  Mark C. Gillies,et al.  Diabetic Macular Edema: Current Treatments , 2007 .

[10]  Alan C. Bovik,et al.  Am-fm image models , 1996 .

[11]  Marios S. Pattichis,et al.  Multiscale AM-FM Methods for Diabetic Retinopathy Lesion Detection , 2010, IEEE Transactions on Medical Imaging.

[12]  F L Ferris,et al.  Photocoagulation for diabetic macular edema. , 1987, Archives of ophthalmology.

[13]  Ole Vilhelm Larsen,et al.  Screening for diabetic retinopathy using computer based image analysis and statistical classification , 2000, Comput. Methods Programs Biomed..

[14]  J. Olson,et al.  Automated detection of microaneurysms in digital red‐free photographs: a diabetic retinopathy screening tool , 2000, Diabetic medicine : a journal of the British Diabetic Association.

[15]  B. van Ginneken,et al.  Automated detection and differentiation of drusen, exudates, and cotton-wool spots in digital color fundus photographs for diabetic retinopathy diagnosis. , 2007, Investigative ophthalmology & visual science.

[16]  Qin Li,et al.  Detection of microaneurysms using multi-scale correlation coefficients , 2010, Pattern Recognit..

[17]  Marios S. Pattichis,et al.  Multiscale AM-FM Demodulation and Image Reconstruction Methods With Improved Accuracy , 2010, IEEE Transactions on Image Processing.

[18]  Bunyarit Uyyanonvara,et al.  Automatic exudates detection from diabetic retinopathy retinal image using fuzzy C-means and morphological methods , 2007 .

[19]  J. Boyce,et al.  Automated detection of diabetic retinopathy in digital retinal images: a tool for diabetic retinopathy screening , 2004, Diabetic medicine : a journal of the British Diabetic Association.

[20]  S. D. Jong SIMPLS: an alternative approach to partial least squares regression , 1993 .

[21]  Nicky Lai,et al.  Clinical Ophthalmology: A Systematic Approach, 5th ed. , 2004 .

[22]  Roberto Hornero,et al.  Retinal image analysis based on mixture models to detect hard exudates , 2009, Medical Image Anal..

[23]  Marios S. Pattichis,et al.  Multiscale AM-FM decompositions with GPU acceleration for diabetic retinopathy screening , 2012, 2012 IEEE Southwest Symposium on Image Analysis and Interpretation.

[24]  P. Sharp,et al.  Automated detection and quantification of retinal exudates , 1993, Graefe's Archive for Clinical and Experimental Ophthalmology.

[25]  Jayanthi Sivaswamy,et al.  Automatic assessment of macular edema from color retinal images , 2012, IEEE Transactions on Medical Imaging.

[26]  Bram van Ginneken,et al.  Automatic detection of red lesions in digital color fundus photographs , 2005, IEEE Transactions on Medical Imaging.

[27]  S. Resnikoff,et al.  Global data on visual impairment in the year 2002. , 2004, Bulletin of the World Health Organization.

[28]  Gwénolé Quellec,et al.  Optimal Wavelet Transform for the Detection of Microaneurysms in Retina Photographs , 2008, IEEE Transactions on Medical Imaging.

[29]  Robert M. Haralick,et al.  Textural Features for Image Classification , 1973, IEEE Trans. Syst. Man Cybern..