SLIGA Based underwater weapon safety and arming system
暂无分享,去创建一个
Abstract The Naval Surface Warfare Center, Indian Head Division (NSWCIHD) is applying microelectromechanical system (MEMS) technology to underwater weapon Safety and Arming (S&A) system development. MEMS technology provides an opportunity to develop a miniaturized S&A system that is more sophisticated with improved safety and reliability at a lower cost compared to current systems. An S&A system prevents premature initiation of the weapon while reliably ensuring initiation at the appropriate time. An S&A system uses multiple sensors and devices. In comparison with other weapon S&A systems, a critical aspect of underwater weapon S&A systems is the mechanical interlock system utilizing actuators and mechanical sensors. This paper describes the design, development and fabrication of S&A SLIGA device prototypes and of a SLIGA based S&A system. NSWCIHD worked with members of the HI-MEMS Alliance during design, development and fabrication. Advancements achieved by the HI-MEMS Alliance and SLIGA S&A design issues are discussed.
[1] Thomas R. Ohnstein,et al. Electromagnetic linear actuators with inductive position sensing , 1996 .