Acceptability of Three Transformer Hottest-Spot Temperature Models

The acceptability of three transformer hottest-spot temperature (HST) models for use in dynamic loading are investigated and discussed in this paper. The hottest-spot models are the modified HST model, Swift's model, and Susa's model. The investigation fitted the models to measured field data obtained from utility transformers using numerical and statistical methods. Acceptability metrics to evaluate the models' accuracy, adequacy, and consistency in predicting HST were evaluated using results from the fitting procedures. These metrics serve as absolute measures to reveal any potential deficiencies in the models when they are used to build hottest-spot models for transformers using field data. The metrics also serve as relative measures to compare the performance of the models to one another. It is shown that the modified HST model and Susa's model are acceptable for implementing models from field data. And it is concluded that the Swift's model is not acceptable because it is structurally inaccurate.

[1]  L. W. Pierce Predicting liquid filled transformer loading capability , 1992, [1992] Record of Conference Papers Industry Applications Society 39th Annual Petroleum and Chemical Industry Conference.

[2]  Daniel Tylavsky,et al.  Prediction of top-oil temperature for transformers using neural networks , 2000 .

[3]  Zoran Radakovic,et al.  A new method for the calculation of the hot-spot temperature in power transformers with ONAN cooling , 2003 .

[4]  T. S. Ramu,et al.  Prediction of hottest spot temperature (HST) in power and station transformers , 2003 .

[5]  Daniel Tylavsky,et al.  Sources of error in substation distribution transformer dynamic thermal modeling , 2000 .

[6]  D.J. Tylavsky,et al.  Transformer thermal modeling: improving reliability using data quality control , 2006, IEEE Transactions on Power Delivery.

[7]  M.K. Pradhan,et al.  Estimation of the hottest spot temperature (HST) in power transformers considering thermal inhomogeniety of the windings , 2004, IEEE Transactions on Power Delivery.

[8]  L. Jauregui-Rivera,et al.  Acceptability of Four Transformer Top-Oil Thermal Models—Part I: Defining Metrics , 2008, IEEE Transactions on Power Delivery.

[9]  S. Tojo Proposition of individual loading guide for power transformers , 2006 .

[10]  Jammalamadaka Introduction to Linear Regression Analysis (3rd ed.) , 2003 .

[11]  L. W. Pierce An investigation of the thermal performance of an oil filled transformer winding , 1992 .

[12]  Matti Lehtonen,et al.  Dynamic thermal modelling of power transformers , 2004 .

[13]  R. S. Girgis,et al.  Calculation of Core Hot-Spot Temperature in Power and Distribution Transformers , 2002, IEEE Power Engineering Review.

[14]  L. Jauregui-Rivera,et al.  Acceptability of Four Transformer Top-Oil Thermal Models—Part II: Comparing Metrics , 2008, IEEE Transactions on Power Delivery.

[15]  James L. Kirtley,et al.  An improved transformer top oil temperature model for use in an on-line monitoring and diagnostic system , 1997 .

[16]  D.J. Tylavsky,et al.  A new model for predicting hottest-spot temperature in transformers , 2008, 2008 40th North American Power Symposium.

[18]  G. Swift,et al.  A fundamental approach to transformer thermal modeling. I. Theory and equivalent circuit , 2001 .