Variations in Arterial Blood Pressure and Photoplethysmography During Mechanical Ventilation

We analyzed ventilation-induced changes in arterial blood pressure and photoplethysmography from waveforms obtained by monitoring 57 patients in the operating room and intensive care unit. Analysis of systolic and pulse pressure variations during positive pressure ventilation, &Dgr;Up, &Dgr;Down, and changes in the preejection period on both arterial and photoplethysmographic waveforms were possible in 49 (86%) patients. The pulse pressure variation and preejection period were similar when calculated using both arterial blood pressure and photoplethysmography, whereas the other variables were different. Photoplethysmographic pulse variation >9% identified patients with arterial pulse pressure variation >13% (area under ROC curve = 0.85) or &Dgr;Down >5 mm Hg (area under ROC curve = 0.85). In hypotensive patients, photoplethysmographic pulse variation >9% remained the best threshold value (pulse pressure variation >13%: area under ROC curve = 0.90; &Dgr;Down >5 mm Hg: area under ROC curve = 0.93) for predicting fluid responsiveness. In conclusion, this study showed that pulse variations observed in the arterial pressure waveform and photoplethysmogram are similiar in response to positive pressure ventilation. Furthermore, photoplethysmographic pulse variation > 9% identifies patients with ventilation-induced arterial blood pressure variation that is likely to respond to fluid administration.

[1]  H A Schwid,et al.  The Effect of Graded Hemorrhage and Intravascular Volume Replacement on Systolic Pressure Variation in Humans During Mechanical and Spontaneous Ventilation , 1995, Anesthesia and analgesia.

[2]  B. Partridge Use of Pulse Oximetry as a Noninvasive Indicator of Intravascular Volume Status , 1987, Journal of clinical monitoring.

[3]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[4]  K. Arakawa,et al.  Pulse Oximetry and Circulatory Kinetics Associated with Pulse Volume Amplitude Measured by Photoelectric Plethysmography , 1986, Anesthesia and analgesia.

[5]  T. L. Rusch,et al.  Signal processing methods for pulse oximetry , 1996, Comput. Biol. Medicine.

[6]  Kirk H. Shelley,et al.  How Does the Plethysmogram Derived from the Pulse Oximeter Relate to Arterial Blood Pressure in Coronary Artery Bypass Graft Patients? , 2001, Anesthesia and analgesia.

[7]  A. Perel,et al.  The effect of tidal volume and intravascular volume state on systolic pressure variation in ventilated dogs , 2004, Intensive Care Medicine.

[8]  A. Perel,et al.  Systolic Blood Pressure Variation is a Sensitive Indicator of Hypovolemia in Ventilated Dogs Subjected to Graded Hemorrhage , 1986, Anesthesiology.

[9]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[10]  J. Teboul,et al.  Using heart-lung interactions to assess fluid responsiveness during mechanical ventilation , 2000, Critical care.

[11]  Karim Bendjelid,et al.  The respiratory change in preejection period: a new method to predict fluid responsiveness. , 2004, Journal of applied physiology.

[12]  Andre Ferland,et al.  Pulse pressure variation predicts fluid responsiveness following coronary artery bypass surgery. , 2004, Chest.

[13]  A. Perel,et al.  Stroke Volume Variation as a Predictor of Fluid Responsiveness in Patients Undergoing Brain Surgery , 2001, Anesthesia and analgesia.

[14]  Mahmood Saghaei,et al.  Evaluating the Relationship Between Arterial Blood Pressure Changes and Indices of Pulse Oximetric Plethysmography , 2002, Anesthesia and analgesia.

[15]  J. C. Dorlas,et al.  Photo-electric plethysmography as a monitoring device in anaesthesia. Application and interpretation. , 1985, British journal of anaesthesia.

[16]  A. Perel,et al.  Systolic Blood Pressure Variation is a Sensitive Indicator of Hypovolemia in Ventilated Dogs Subjected to Graded Hemorrhage , 1986, Anesthesiology.

[17]  D. Chemla,et al.  Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. , 2000, American journal of respiratory and critical care medicine.

[18]  Peter Lamm,et al.  Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function , 2003, Critical care medicine.

[19]  R. Pizov,et al.  Pulse oximetry plethysmographic waveform during changes in blood volume. , 1999, British journal of anaesthesia.

[20]  J. Hanley,et al.  A method of comparing the areas under receiver operating characteristic curves derived from the same cases. , 1983, Radiology.

[21]  L. B. Cook,et al.  Extracting arterial flow waveforms from pulse oximeter waveforms , 2001, Anaesthesia.

[22]  M. Pinsky Using ventilation-induced aortic pressure and flow variation to diagnose preload responsiveness , 2004, Intensive Care Medicine.

[23]  A. Perel,et al.  Assessing fluid responsiveness by the systolic pressure variation in mechanically ventilated patients. Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension. , 1998, Anesthesiology.

[24]  Daniel A. Reuter,et al.  Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery , 2002, Intensive Care Medicine.

[25]  H F Mahieu,et al.  Photoelectric plethysmography--some fundamental aspects of the reflection and transmission method. , 1981, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[26]  G. Lebuffe,et al.  Systolic Pressure Variation as a Guide to Fluid Therapy in Patients with Sepsis‐induced Hypotension , 1998, Anesthesiology.

[27]  Y Lecarpentier,et al.  Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP. , 1999, American journal of respiratory and critical care medicine.