Micro gas analyzers for environmental and medical applications.

In this review, novel microsystems and microdevices to measure gaseous species for environmental analysis and medical diagnostics are described. Miniaturization of analyzers makes field measurements affordable. As well, high sensitivity and good time resolution can be achieved by miniaturization. Some such devices have already been successfully applied to real environmental analyses. Mobile monitoring is available with the use of micro gas analyzers to investigate the natural environment, air pollution and to detect nerve or explosive gases released accidentally or through terrorist activities. Miniature devices are also attractive for medical analyses. Gases produced from the human body reflect gases contained in the blood and certain metabolic conditions. Noninvasive monitoring using miniature devices is available in hospitals and in a patient's home. Many investigations have been conducted using wet and dry chemistry methods for both applications. Instruments employing wet chemistries, which comprise liquid droplets, liquid film, miniature diffusion scrubbers, and microfluidic devices have been studied. Among the instruments using dry methods, miniature samplers, portable gas chromatographs, and microfabricated gas chromatographs have all been investigated. These instruments are expected to usher in a new era of environmental monitoring and will find uses in many medical applications.

[1]  Myung-Haeng Hur,et al.  Reduction of mouth malodour and volatile sulphur compounds in intensive care patients using an essential oil mouthwash , 2007, Phytotherapy research : PTR.

[2]  M. Hutterli,et al.  Measurement of atmospheric formaldehyde with a diffusion scrubber and light‐emitting diode–liquid‐core waveguide based fluorometry , 2001 .

[3]  A. Cǎpriţǎ,et al.  Continuous permeation of analytes through a thin poly(dimethylsiloxane) membrane followed by sorbent trapping for their gas chromatographic monitoring. , 2002, Journal of chromatography. A.

[4]  K. Ward,et al.  Immobilization of cytochrome c oxidase into electrode-supported lipid bilayer membranes for in vitro cytochrome c sensing , 2006, IEEE Sensors Journal.

[5]  K. Toda,et al.  Measurement of ammonia in human breath with a liquid-film conductivity sensor. , 2006, Analytical chemistry.

[6]  Xiangmin Zhang,et al.  Field analysis of benzene, toluene, ethylbenzene and xylene in water by portable gas chromatography-microflame ionization detector combined with headspace solid-phase microextraction. , 2006, Talanta.

[7]  Richard H. Lambert,et al.  Utilization of a portable microchip gas chromatograph to identify and reduce fugitive emissions at a pharmaceutical manufacturing plant , 1997 .

[8]  K. Toda,et al.  Miniature Liquid Flow Sensor and Feedback Control of Electroosmotic and Pneumatic Flows for a Micro Gas Analysis System , 2006, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[9]  Dae-Gab Gweon,et al.  A high-speed miniature screening gaschromatograph with flame ionization detector , 2005 .

[10]  M. Oshima,et al.  On-Line Collection/Concentration and Detection of Sulfur Dioxide in Air by Flow-Injection Spectrophotometry Coupled with a Chromatomembrane Cell , 2004, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[11]  C. Bucca,et al.  Diagnostic classification of persistent rhinitis and its relationship to exhaled nitric oxide and asthma: a clinical study of a consecutive series of patients. , 2007, Chest.

[12]  J. Pawliszyn,et al.  Sampling and determination of volatile organic compounds with needle trap devices. , 2005, Journal of chromatography. A.

[13]  Purnendu K. Dasgupta,et al.  High-Sensitivity Gas Sensors Based on Gas-Permeable Liquid Core Waveguides and Long-Path Absorbance Detection , 1998 .

[14]  M. Azad,et al.  Single column trapping/separation and chemiluminescence detection for on-site measurement of methyl mercaptan and dimethyl sulfide. , 2006, Analytical chemistry.

[15]  Matthew Glenn Blain,et al.  Towards the hand-held mass spectrometer: design considerations, simulation, and fabrication of micrometer-scaled cylindrical ion traps , 2004 .

[16]  Hyeun Joong Yoon,et al.  Fabrication of a novel micro time-of-flight mass spectrometer , 2002 .

[17]  Takeo Yamada,et al.  Separate detection of BTX mixture gas by a microfluidic device using a function of nanosized pores of mesoporous silica adsorbent. , 2002, Analytical chemistry.

[18]  A. Mbi,et al.  A new acetone detection device using cavity ringdown spectroscopy at 266 nm: evaluation of the instrument performance using acetone sample solutions , 2007 .

[19]  Takayoshi Hayashi,et al.  Fluorescence-intensity changes in organic dyes impregnated in porous glass on exposure to NO2 , 1999 .

[20]  R. Cooks,et al.  Miniature mass analyzers , 2000, Journal of mass spectrometry : JMS.

[21]  P. Dasgupta,et al.  Light at the end of the tunnel: recent analytical applications of liquid-core waveguides , 2004 .

[22]  D. Stick,et al.  Planar ion trap geometry for microfabrication , 2004 .

[23]  Chunrong Jia,et al.  Rapid determination of ETS markers with a prototype field-portable GC employing a microsensor array detector. , 2007, Journal of environmental monitoring : JEM.

[24]  M Wessling,et al.  Membranes and microfluidics: a review. , 2006, Lab on a chip.

[25]  L R Narasimhan,et al.  Correlation of breath ammonia with blood urea nitrogen and creatinine during hemodialysis , 2001, Proceedings of the National Academy of Sciences of the United States of America.

[26]  Takashi Korenaga,et al.  Development and optimization of a lab-on-a-chip device for the measurement of trace nitrogen dioxide gas in the atmosphere. , 2006, The Analyst.

[27]  W. L. Borst,et al.  Soap bubbles in analytical chemistry. Conductometric determination of sub-parts per million levels of sulfur dioxide with a soap bubble. , 2006, Analytical chemistry.

[28]  K. Toda,et al.  Micro-gas analysis system μGAS comprising a microchannel scrubber and a micro-fluorescence detector for measurement of hydrogen sulfide , 2004 .

[29]  Wouter Olthuis,et al.  Miniaturized measurement system for ammonia in air , 2004 .

[30]  J. Simon,et al.  Does the chromatomembrane cell improve the quality of environmental analysis? , 1999, Talanta.

[31]  Michael E. Webber,et al.  Laser-based photoacoustic ammonia sensors for industrial applications , 2002 .

[32]  A. Datta,et al.  Microfabrication and characterization of teflon AF-coated liquid core waveguide channels in silicon , 2003 .

[33]  Takashi Korenaga,et al.  On-line determination of trace sulfur dioxide in air by integrated microchip coupled with fluorescence detection. , 2005, Talanta.

[34]  John Tulip,et al.  Pulsed quantum cascade laser-based cavity ring-down spectroscopy for ammonia detection in breath. , 2006, Applied optics.

[35]  P. Dasgupta,et al.  Measurement of nitrogen dioxide and nitrous acid using gas-permeable liquid core waveguides , 2001 .

[36]  Bogusław Buszewski,et al.  Human exhaled air analytics: biomarkers of diseases. , 2007, Biomedical chromatography : BMC.

[37]  Relationship between Concentrations of Acetone Vapor Emanated from Human Skin and .BETA.-Hydroxybutyrate in Blood , 2005 .

[38]  R. A. McGill,et al.  Micropreconcentrator for Enhanced Trace Detection of Explosives and Chemical Agents , 2006, IEEE Sensors Journal.

[39]  J Wang,et al.  A pulse amperometric sensor for the measurement of atmospheric hydrogen peroxide. , 1996, Analytical chemistry.

[40]  M. Oshima,et al.  Absorption, concentration and determination of trace amounts of air pollutants by flow injection method coupled with a chromatomembrane cell system: application to nitrogen dioxide determination. , 2002, Talanta.

[41]  K. Toda,et al.  Micro gas analysis system for measurement of atmospheric hydrogen sulfide and sulfur dioxide. , 2005, Lab on a chip.

[42]  R. Chiriac,et al.  Development of a pre-concentrator-thermo-desorber/micro-gas chromatograph/mass spectrometer coupling for on-site analyses of emissions of volatile organic compounds from landfills , 2007 .

[43]  A. van den Berg,et al.  Selective low concentration ammonia sensing in a microfluidic lab-on-a-chip , 2006, IEEE Sensors Journal.

[44]  J. Simon,et al.  Flow injection analysis with the chromatomembrane--a new device for gaseous/liquid and liquid/liquid extraction. , 1994, Talanta.

[45]  P. Dasgupta,et al.  Measurement of gaseous hydrogen peroxide with a liquid core waveguide chemiluminescence detector , 2001 .

[46]  Dasgupta,et al.  A continuous film-recirculable drop gas-liquid equilibration device. Measurement of trace gaseous ammonia , 2000, Analytical chemistry.

[47]  D. Levitt,et al.  Comparison of volatile sulfur compound concentrations measured with a sulfide detector vs. gas chromatography. , 2002, Journal of dental research.

[48]  A. Cardoso,et al.  Fluorometric fiber optic drop sensor for atmospheric hydrogen sulfide. , 1997, Talanta.

[49]  J. M. Bauer,et al.  Recent advancements in the gas-phase MicroChemLab , 2006, IEEE Sensors Journal.

[50]  K. Toda,et al.  Trace gas measurement with an integrated porous tube collector/long-path absorbance detector. , 2003, Analytical chemistry.

[51]  Chia-Jung Lu,et al.  Portable gas chromatograph with tunable retention and sensor array detection for determination of complex vapor mixtures. , 2003, Analytical chemistry.

[52]  F. K. Marcondes,et al.  Influence of anxiety on the production of oral volatile sulfur compounds. , 2006, Life sciences.

[53]  Frank K. Tittel,et al.  Quantum cascade laser-based integrated cavity output spectroscopy of exhaled nitric oxide , 2006 .

[54]  A. Star,et al.  Carbon nanotube sensors for exhaled breath components , 2007 .

[55]  K. Jinno,et al.  Simultaneous derivatization/preconcentration of volatile aldehydes with a miniaturized fiber-packed sample preparation device designed for gas chromatographic analysis , 2006, Analytical and bioanalytical chemistry.

[56]  Yasuko Yamada Maruo,et al.  Measurement of local variations in atmospheric nitrogen dioxide levels in Sapporo, Japan, using a new method with high spatial and high temporal resolution , 2003 .

[57]  Takeo Yamada,et al.  Portable automatic BTX measurement system with microfluidic device using mesoporous silicate adsorbent with nano-sized pores , 2003 .

[58]  P. Dasgupta,et al.  Atmospheric ozone measurement with an inexpensive and fully automated porous tube collector-colorimeter. , 2008, Talanta.

[59]  Dasgupta,et al.  Measurement of atmospheric hydrogen peroxide and hydroxymethyl hydroperoxide with a diffusion scrubber and light emitting diode-liquid core waveguide-based fluorometry , 2000, Analytical chemistry.

[60]  A. Ceccarini,et al.  Breath analysis: trends in techniques and clinical applications , 2005 .

[61]  A. Chiriac,et al.  Membrane and trap system for continuous monitoring of volatile organic compounds using a portable gas chromatograph with thermal conductivity detector , 2002 .

[62]  Jianzhong Li,et al.  Determination of acetone in breath , 2005 .

[63]  R. Pereiro,et al.  Optical fibre sensor for hydrogen sulphide monitoring in mouth air , 2002 .

[64]  S. Szefler,et al.  The Aerocrine exhaled nitric oxide monitoring system NIOX is cleared by the US Food and Drug Administration for monitoring therapy in asthma. , 2004, The Journal of allergy and clinical immunology.

[65]  Tryggve Hemmingsson,et al.  Novel Hand-Held Device for Exhaled Nitric Oxide-Analysis in Research and Clinical Applications , 2005, Journal of Clinical Monitoring and Computing.

[66]  John P Hatch,et al.  Cut-off levels for breath carbon monoxide as a marker for cigarette smoking. , 2005, Addiction.

[67]  T. Namihira,et al.  Sequential multiple analyses of atmospheric nitrous acid and nitrogen oxides. , 2007, Talanta.

[68]  K. Toda,et al.  Fluorometric field instrument for continuous measurement of atmospheric hydrogen sulfide. , 2001, Analytical Chemistry.

[69]  Keisuke Toda Development of miniature key devices for flow analysis and their applications , 2004 .

[70]  Gerard Wysocki,et al.  Performance of an exhaled nitric oxide and carbon dioxide sensor using quantum cascade laser-based integrated cavity output spectroscopy. , 2007, Journal of biomedical optics.

[71]  K. Toda,et al.  Hybrid microfabricated device for field measurement of atmospheric sulfur dioxide. , 2002, Analytical chemistry.

[72]  Janusz Pawliszyn,et al.  On-site monitoring of biogenic emissions from Eucalyptus dunnii leaves using membrane extraction with sorbent interface combined with a portable gas chromatograph system. , 2004, The Analyst.

[73]  Air-cooled cold trap channel integrated in a microfluidic device for monitoring airborne BTEX with an improved detection limit. , 2002, Analytical chemistry.

[74]  K. Wise,et al.  First-generation hybrid MEMS gas chromatograph. , 2005, Lab on a chip.

[75]  Wouter Olthuis,et al.  Sampling small volumes of ambient ammonia using a miniaturized gas sampler. , 2004, Lab on a chip.

[76]  K. Toda,et al.  In situ gas generation for micro gas analysis system. , 2007, Analytica chimica acta.

[77]  P. Dasgupta,et al.  Selective Measurement of Gaseous Hydrogen Peroxide with Light Emitting Diode-Based Liquid-Core Waveguide Absorbance Detector , 2003, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[78]  Janusz Pawliszyn,et al.  Design of continuous‐monitoring device based on membrane extraction with sorbent interface and micro‐gas chromatograph , 2001 .

[79]  J. Pawliszyn,et al.  Solid phase microextraction with thermal desorption using fused silica optical fibers , 1990 .

[80]  S. Terry,et al.  A gas chromatographic air analyzer fabricated on a silicon wafer , 1979, IEEE Transactions on Electron Devices.

[81]  A. Tangerman,et al.  Intra- and extra-oral halitosis: finding of a new form of extra-oral blood-borne halitosis caused by dimethyl sulphide. , 2007, Journal of clinical periodontology.

[82]  M. Sigrist,et al.  Spectroscopic investigation of methylated amines by a cavity-ringdown-based spectrometer. , 2007, Applied Optics.

[83]  E. Zellers,et al.  Multiple-stage microfabricated preconcentrator-focuser for micro gas chromatography system , 2005, Journal of Microelectromechanical Systems.

[84]  Jan C.T. Eijkel,et al.  Towards an on-chip gas chromatograph: the development of a gas injector and a dc plasma emission detector , 2002 .

[85]  M. Oshima,et al.  The application of the chromatomembrane cell for the absorptive sampling of nitrogen dioxide followed by continuous determination of nitrite using a micro-flow injection system. , 2002, Talanta.

[86]  Guigen Li,et al.  Chemiluminometric measurement of atmospheric ozone with photoactivated chromotropic acid. , 2003, Analytical chemistry.

[87]  J. Birks,et al.  Luminol/H2O2 chemiluminescence detector for the analysis of nitric oxide in exhaled breath. , 1999, Analytical chemistry.

[88]  T. Korenaga,et al.  Analytical Chemistry for Environmental and Human Health. Development of a gas absorption microchip using porous glass and its evaluation for analytical applications. , 2000 .

[89]  R. Ghodssi,et al.  A fast-response microfluidic gas concentrating device for environmental sensing , 2007 .

[90]  E. Wapelhorst,et al.  Mass spectra measured by a fully integrated MEMS mass spectrometer , 2007 .

[91]  Purnendu K. Dasgupta,et al.  Measurement of atmospheric formaldehyde using a drop collector and in-situ colorimetry , 1997 .

[92]  Haoshen Zhou,et al.  Improvement of on-site microfluidic benzene, toluene, xylene (BTX) gas sensor loaded with nanostructured mesoporous silicate , 2003 .

[93]  Takayoshi Hayashi,et al.  A ppb-level NO2 detection system using coloration reactions in porous glass and its humidity dependence , 2000 .

[94]  M. Agah,et al.  High-Speed MEMS-Based Gas Chromatography , 2004, Journal of Microelectromechanical Systems.

[95]  K. Toda,et al.  NEW APPLICATIONS OF CHEMILUMINESCENCE FOR SELECTIVE GAS ANALYSIS , 2007 .

[96]  T. Namihira,et al.  Micro-gas analysis system for measurement of nitric oxide and nitrogen dioxide: respiratory treatment and environmental mobile monitoring. , 2007, Analytica chimica acta.

[97]  W. Whitten,et al.  Microfabricated quadrupole ion trap for mass spectrometer applications. , 2006, Physical review letters.

[98]  N. Sterer,et al.  Effect of visible light on malodour production by mixed oral microflora. , 2005, Journal of medical microbiology.

[99]  Yasuko Yamada Maruo,et al.  Coloration reactions between NO2 and organic compounds in porous glass for cumulative gas sensor , 1998 .

[100]  O. Niwa,et al.  Microfluidic device for airborne BTEX detection. , 2001, Analytical chemistry.

[101]  T. Tsuda,et al.  Identification of Gas Emanated from Human Skin: Methane, Ethylene, and Ethane , 2005, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[102]  Takayoshi Hayashi,et al.  System for detecting environmental ppb-level nitrogen dioxide I , 1999 .

[103]  K. Toda,et al.  Highly Sensitive Flow Analysis of Trace Level Arsenic in Water Based on Vaporization-collection In-line Preconcentration , 2005 .

[104]  T. Tsuda,et al.  Relationship between skin acetone and blood β-hydroxybutyrate concentrations in diabetes , 2006 .

[105]  J. Jakmunee,et al.  Hybrid fluorometric flow analyzer for ammonia. , 2006, Analytical chemistry.

[106]  T. Tsuda,et al.  Identification of Ammonia in Gas Emanated from Human Skin and Its Correlation with That in Blood , 2005, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[107]  P. Dasgupta,et al.  Robust hybrid flow analyzer for formaldehyde. , 2008, Environmental science & technology.

[108]  G. Collins,et al.  Development of a microfabricated impinger for on-chip gas phase sampling , 2005 .

[109]  A. Fried,et al.  Summertime ambient formaldehyde in five U.S. metropolitan areas: Nashville, Atlanta, Houston, Philadelphia, and Tampa. , 2005, Environmental science & technology.

[110]  T. Korenaga,et al.  Application of a monolithic silica capillary adsorbent for the preconcentration of airborne trichloroethylene and tetrachloroethylene , 2006, Analytical and bioanalytical chemistry.

[111]  Shoji Motomizu,et al.  On-line collection/concentration of trace amounts of formaldehyde in air with chromatomembrane cell and its sensitive determination by flow injection technique coupled with spectrophotometric and fluorometric detection. , 2005, Talanta.

[112]  J. Pawliszyn,et al.  Breath analysis and monitoring by membrane extraction with sorbent interface. , 2002, Analytical chemistry.

[113]  P. Dasgupta,et al.  Measurement of gaseous and aqueous trace formaldehyde: Revisiting the pentanedione reaction and field applications , 2005 .

[114]  Purnendu K. Dasgupta,et al.  Liquid Droplet. A Renewable Gas Sampling Interface , 1995 .

[115]  K. Toda Trends in Atmospheric Trace Gas Measurement Instruments with Membrane-based Gas Diffusion Scrubbers , 2004, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[116]  R. Mukhopadhyay Research Profile: Measuring isoprene in breath , 2007 .

[117]  Michael E. Webber,et al.  Ultra-sensitive ambient ammonia detection using CO2-laser-based photoacoustic spectroscopy , 2003 .

[118]  A. Manz,et al.  Micro total analysis systems. Latest advancements and trends. , 2006, Analytical chemistry.

[119]  Takayoshi Hayashi,et al.  A ppb-level NO2 gas sensor using coloration reactions in porous glass , 1999 .

[120]  Abul Kalam Azad,et al.  On-site measurements of hydrogen sulfide and sulfur dioxide emissions from tidal flat sediments of Ariake Sea, Japan , 2005 .

[121]  K. Toda,et al.  Field instrument for simultaneous large dynamic range measurement of atmospheric hydrogen sulfide, methanethiol, and sulfur dioxide. , 2004, Environmental Science and Technology.

[122]  Edward T. Zellers,et al.  Microfabricated preconcentrator-focuser for a microscale gas chromatograph , 2003 .

[123]  R. Sacks,et al.  Silicon microfabricated column with microfabricated differential mobility spectrometer for GC analysis of volatile organic compounds. , 2005, Analytical chemistry.

[124]  Han Gardeniers,et al.  Micro- and nanofluidic devices for environmental and biomedical applications , 2004 .

[125]  J. Bagg,et al.  Clinical examination of subjects with halitosis. , 2007, Oral diseases.

[126]  P. Dasgupta,et al.  Pulsed excitation source multiplexed fluorometry for the simultaneous measurement of multiple analytes. Continuous measurement of atmospheric hydrogen peroxide and methyl hydroperoxide. , 2003, Analytical chemistry.

[127]  Wolfram Miekisch,et al.  From highly sophisticated analytical techniques to life-saving diagnostics: Technical developments in breath analysis , 2006 .

[128]  R. Sacks,et al.  High-performance, static-coated silicon microfabricated columns for gas chromatography. , 2006, Analytical chemistry.

[129]  S. Hirata,et al.  Speciation-capable field instrument for the measurement of arsenite and arsenate in water. , 2005, Analytical chemistry.

[130]  K. Toda,et al.  Can breath isoprene be measured by ozone chemiluminescence? , 2007, Analytical chemistry.

[131]  Purnendu K. Dasgupta,et al.  A Renewable Liquid Droplet as a Sampler and a Windowless Optical Cell. Automated Sensor for Gaseous Chlorine , 1995 .

[132]  Qingyu Song,et al.  Handheld rectilinear ion trap mass spectrometer. , 2006, Analytical chemistry.