Analysis of Non-Sinusoidal Steady Electric Field of ±500 kV Converter Transformer

The line side winding is under the fundamental frequency AC voltage, while the valve side winding contains not only fundamental AC voltage component, but also the DC voltage component, fundamental AC voltage component, and higher harmonic voltage components when the converter transformer is at its normal operating condition, and the electric field of converter transformer is a non-sinusoidal steady one. To analyze the non-sinusoidal steady electric field containing the DC component, fundamental AC and higher harmonic components, the voltage spectrum of the valve winding in a ±500 kV converter transformer is firstly analyzed, and the non-sinusoidal periodic steady electric field is obtained by the fast discrete Fourier transform. Different resistivity of the oil and oil-immersed paper is adopted to simulate the aging of oil paper insulation at operation, and get the non-sinusoidal steady electric field.

[1]  Li Wen-ping Development of UHVDC Converter Transformer , 2010 .

[2]  Li Jinzhong Analysis of Nonlinear Electric Field of Oil-paper Insulation Under AC-DC Hybrid Voltage by Fixed Point Method Combined With FEM in Frequency Domain , 2012 .

[3]  Xie Dexin Analysis of transient electric field in converter transformer , 2001 .

[4]  Li Dongxue Analysis on Transient Electric Field at Ends of Valve-side Winding in Converter Transformer , 2012 .

[5]  Yao Yuan Study on Electric Field Characteristics at Ends of Valve-side Winding in Converter Transformer , 2006 .

[6]  Zhou Wenjun Electric Field Characteristic Calculation on Typical Oil-paper Combination Insulation Under Polarity Reversal , 2008 .

[7]  Chen Zhi-wei Numerical Analysis of Electric Field in Valve Side Lead-Out Wire for UHV DC Converter Transformer , 2009 .

[8]  J. Ozawa,et al.  DC Flashover Voltage Characeteristics and Their Calculation Method for Oil-Immersed Insulation Systems in HVDC Transformers , 1986, IEEE Transactions on Power Delivery.

[9]  Luo Bing Study on Electric Field Distribution of ±800 kV Converting Transformer Bushing Outlet Terminal during Polarity Reversal Test , 2009 .

[10]  J. Ozawa,et al.  DC Flashover Voltage Characteristics and Their Calculation Method for Oil-Immersed Insulation Systems in HVDC Transformers , 1986, IEEE Power Engineering Review.

[11]  Zhang Hanfan Simulation Analysis on Winding Current of Three-Chang ±500 kV Converter Transformer under Different Operating Conditions , 2015 .