Operational Research of VRLA Battery

In the following article research results for VRLA gel battery performance in the dynamic load cycle is presented. The research was conducted for several-hundred consecutive charging/discharging cycles. In the work there are presented changes of usable capacity of the battery and impact on a life-time of the battery in dynamic load conditions. There is also presented the effect of load current value on heat emission process, caused by an increase of temperature values on the battery casing and terminals. Acquired results are compared to operational conditions provided by the manufacturer. The research was conducted on two factory new VRLA batteries, which in the course of the tests were completely worn out.

[1]  Hendrik Johannes Bergveld,et al.  Battery management systems : design by modelling , 2001 .

[2]  J. Mączak,et al.  Aspects of balanced development of RES and distributed micro-cogeneration use in Poland: Case study of a µCHP with Stirling engine , 2016 .

[3]  Krzysztof Bogdziński,et al.  Research study of HONDA NHX 110 powered by an alternative fuel , 2019, IOP Conference Series: Earth and Environmental Science.

[4]  Adrian Chmielewski,et al.  Experimental Research of Electrochemical Energy Storage , 2017, AUTOMATION.

[5]  Adrian Chmielewski,et al.  Hybrid Energy Storage Based on Ultracapacitor and Lead Acid Battery: Case Study , 2018, AUTOMATION.

[6]  Jakub Lasocki,et al.  Assessment of the impact of dynamic states of an internal combustion engine on its operational properties , 2015 .

[7]  Pavlos Nikolaidis,et al.  A comparative review of electrical energy storage systems for better sustainability , 2017 .

[8]  Przemysław Szulim,et al.  Experimental Evaluation of Mathematical and Artificial Neural Network Modeling of Energy Storage System , 2017 .

[9]  Szymon Gontarz,et al.  Research Study of the Micro Cogeneration System with Automatic Loading Unit , 2016, AUTOMATION.

[10]  Jarosław Milewski,et al.  Control strategy for an Internal Combustion engine fuelled by Natural Gas operating in Distributed Generation , 2012 .

[11]  Przemysław Szulim,et al.  Test bench and model research of hybrid energy storage , 2018 .

[12]  Krzysztof Bogdziński,et al.  Research on HONDA NHX 110 fueled with biogas, CNG and E85 , 2019, IOP Conference Series: Earth and Environmental Science.

[13]  Raouf Fathallah,et al.  Fatigue reliability prediction of metallic shot peened-parts based on Wöhler curve , 2017 .

[14]  Jihong Wang,et al.  Overview of current development in electrical energy storage technologies and the application potential in power system operation , 2015 .

[15]  Thilo Bocklisch,et al.  Hybrid energy storage systems for renewable energy applications , 2015 .

[16]  S. Radkowski,et al.  Prosumer on the energy market : case study , 2015 .

[17]  E. Karden SECONDARY BATTERIES – LEAD– ACID SYSTEMS | Automotive Batteries: New Developments , 2009 .

[18]  Jakub Mozaryn,et al.  Model-Based Research on Ultracapacitors , 2018, AUTOMATION.

[19]  Piotr Orliński,et al.  Evaluation of the biological methane potential of various feedstock for the production of biogas to supply agricultural tractors , 2016 .