Analysis of Synchronization Stability for Multi VSCs Parallel-Connected to Weak Grids by Improved Net Damping Criterion

Recent studies show that the loss of stability for a voltage-source converter (VSC) in weak-grid connection is largely related to its synchronization unit, i.e., the phase-locked loop (PLL). This paper studies the synchronization stability of a system comprised by two VSCs in parallel connection to a weak grid. A reduced transfer function based small-signal model, which can allow for the interactions between PLL and converter outer power controls, is first proposed. Then, an improved net damping criterion is used to analyze the damping and stability characters of such system under various operating conditions and different controller configurations. Compared to the conventional net damping criterion, the used criterion has wider applicability in terms of stability judgment. Case studies show that the studied system tends to be unstable at weak-grid or heavy-loading conditions. The instability can be in the form of oscillations or monotonic divergence, in which, the latter is more likely to occur for the converters without grid voltage regulation capabilities. Besides, the net damping-based sensitivity studies can provide guidance on control tuning or design for stability enhancement. Detailed model-based time domain simulations are conducted to verify the analysis results.

[1]  Robert Turner,et al.  A Case Study on the Application of the Nyquist Stability Criterion as Applied to Interconnected Loads and Sources on Grids , 2013, IEEE Transactions on Industrial Electronics.

[2]  Marco Liserre,et al.  Analysis of the Interaction Among Power Converters Through Their Synchronization Mechanism , 2019, IEEE Transactions on Power Electronics.

[3]  Zheng Yuan,et al.  Analysis on the dynamic behaviours and interactions of VSC-MTDC grid , 2017 .

[4]  Dong Liu,et al.  Modeling and Stability Analysis of VSC Internal Voltage in DC-Link Voltage Control Timescale , 2018, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[5]  Jiabing Hu,et al.  Analysis of Low-Frequency Stability in Grid-Tied DFIGs by Nonminimum Phase Zero Identification , 2018, IEEE Transactions on Energy Conversion.

[6]  Frede Blaabjerg,et al.  Passivity-Based Stability Analysis and Damping Injection for Multiparalleled VSCs with LCL Filters , 2017, IEEE Transactions on Power Electronics.

[7]  Rolando Burgos,et al.  Stability Analysis of Power Systems With Multiple STATCOMs in Close Proximity , 2020, IEEE Transactions on Power Electronics.

[8]  Bo Wen,et al.  Impedance-Based Analysis of Grid-Synchronization Stability for Three-Phase Paralleled Converters , 2014, IEEE Transactions on Power Electronics.

[9]  L Harnefors,et al.  Proof and Application of the Positive-Net-Damping Stability Criterion , 2011, IEEE Transactions on Power Systems.

[10]  I. Canay A Novel Approach to the Torsional Interaction and Electrical Damping of the Synchronous Machine Part II: Application to an arbitrary network , 1982, IEEE Transactions on Power Apparatus and Systems.

[11]  A. Gole,et al.  Impact of Short-Circuit Ratio and Phase-Locked-Loop Parameters on the Small-Signal Behavior of a VSC-HVDC Converter , 2014, IEEE Transactions on Power Delivery.

[12]  Jun Liang,et al.  Positive-Net-Damping Stability Criterion in Grid-Connected VSC Systems , 2017, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[13]  Massimo Bongiorno,et al.  Stability Analysis of Two-Terminal VSC-HVDC Systems Using the Net-Damping Criterion , 2016, IEEE Transactions on Power Delivery.

[14]  Lingling Fan,et al.  An Explanation of Oscillations Due to Wind Power Plants Weak Grid Interconnection , 2018, IEEE Transactions on Sustainable Energy.

[15]  Jiabing Hu,et al.  Modeling of VSCs Considering Input and Output Active Power Dynamics for Multi-Terminal HVDC Interaction Analysis in DC Voltage Control Timescale , 2019, IEEE Transactions on Energy Conversion.

[16]  R. Iravani,et al.  On the application of the complex torque coefficients method to the analysis of torsional dynamics , 2005, IEEE Transactions on Energy Conversion.

[17]  Xiongfei Wang,et al.  Stability Analysis of Grid-Connected Voltage-Source Converters Using SISO Modeling , 2019, IEEE Transactions on Power Electronics.

[18]  Khaled Mohammad Alawasa,et al.  Active Mitigation of Subsynchronous Interactions Between PWM Voltage-Source Converters and Power Networks , 2014, IEEE Transactions on Power Electronics.

[19]  C. E. Ugalde-Loo,et al.  Criterion for the Electrical Resonance Stability of Offshore Wind Power Plants Connected Through HVDC Links , 2017, IEEE Transactions on Power Systems.

[20]  Lennart Harnefors,et al.  Modeling of Three-Phase Dynamic Systems Using Complex Transfer Functions and Transfer Matrices , 2007, IEEE Transactions on Industrial Electronics.

[21]  Xiaoming Yuan,et al.  SISO Equivalent of MIMO VSC-Dominated Power Systems for Voltage Amplitude and Phase Dynamic Analyses in Current Control Timescale , 2019, IEEE Transactions on Energy Conversion.

[22]  Guorong Zhu,et al.  Grid-Synchronization Stability Analysis for Multi DFIGs Connected in Parallel to Weak AC Grids , 2019 .

[23]  Dushan Boroyevich,et al.  Phase-Locked Loop Noise Reduction via Phase Detector Implementation for Single-Phase Systems , 2011, IEEE Transactions on Industrial Electronics.

[24]  I. M. Canay,et al.  A Novel Approach to the Torsional Interaction and Electrical Damping of the Synchronous Machine Part I: Theory , 1982, IEEE Transactions on Power Apparatus and Systems.

[25]  Frede Blaabjerg,et al.  Passivity-Based Stability Assessment of Grid-Connected VSCs—An Overview , 2016, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[26]  Jiabing Hu,et al.  Inertia Provision and Estimation of PLL-Based DFIG Wind Turbines , 2017, IEEE Transactions on Power Systems.

[27]  Yan Li,et al.  Modeling and Stability Analysis of DC-Link Voltage Control in Multi-VSCs With Integrated to Weak Grid , 2017, IEEE Transactions on Energy Conversion.

[28]  Massimo Bongiorno,et al.  Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters , 2007, IEEE Transactions on Industrial Electronics.

[29]  Hao Yuan,et al.  Modeling of Grid-Connected VSCs for Power System Small-Signal Stability Analysis in DC-Link Voltage Control Timescale , 2017, IEEE Transactions on Power Systems.