Incremental spinal anaesthesia for elective caesarean section: maternal and fetal haemodynamic effects.

We have performed serial haemodynamic investigations in 20 women undergoing elective Caesarean section under continuous spinal anaesthesia with a 32-gauge catheter with 0.5% heavy bupivacaine. Cardiac output was measured by Doppler and cross-sectional echocardiography at the aortic valve. Doppler flow velocity waveforms were recorded also from the umbilical artery. A block to T4 or above was achieved in all patients. The median dose of 0.5% bupivacaine administered was 2.0 ml (range 1.5-4.5 ml). Mean cardiac output increased from 7 to 8 litre min-1 after preloading with Ringer lactate solution 1.5 litre and then remained unchanged after injection of bupivacaine. Two subjects developed hypotension, although mean values of arterial pressure and umbilical artery pulsatility index did not change. The median umbilical artery pH was 7.27 (range 6.98-7.32) and there was a significant correlation between pH and the maximum percentage decrease in cardiac output. The results suggest that continuous spinal anaesthesia is associated with greater haemodynamic stability than single bolus spinal injection.

[1]  J. Benson U.S. Food and Drug Administration safety alert: cauda equina syndrome associated with use of small-bore catheters in continuous spinal anesthesia. , 1992, AANA journal.

[2]  C. Rodeck,et al.  Maternal and fetal haemodynamic effects of spinal and extradural anaesthesia for elective caesarean section. , 1992, British journal of anaesthesia.

[3]  B. Ross,et al.  Local Anesthetic Distribution in a Spinal Model: A Possible Mechanism of Neurologic Injury after Continuous Spinal Anesthesia , 1991, Regional Anesthesia & Pain Medicine.

[4]  A. Rosenberg,et al.  Catheter spinal anesthesia and cauda equina syndrome: an alternative view. , 1991, Anesthesia and analgesia.

[5]  K. Drasner,et al.  Cauda Equina Syndrome After Continuous Spinal Anesthesia , 1991, Anesthesia and analgesia.

[6]  N. Goodman,et al.  Comparison of incremental spinal anesthesia using a 32-gauge catheter with extradural anaesthesia for elective caesarean section. , 1991, British journal of anaesthesia.

[7]  I. Kestin,et al.  Incremental spinal anaesthesia using a 32‐gauge catheter , 1991, Anaesthesia.

[8]  D. Dutton,et al.  Extradural, spinal or combined block for obstetric surgical anaesthesia. , 1991, British journal of anaesthesia.

[9]  P. Brownridge Spinal anaesthesia in obstetrics. , 1991, British journal of anaesthesia.

[10]  H. McQuay,et al.  32‐gauge spinal catheters through 26‐gauge needles , 1990, Anaesthesia.

[11]  T. Benedetti,et al.  Measurement of Cardiac Output in Pregnancy by Doppler Technique , 1990, American journal of perinatology.

[12]  D. Lambert,et al.  Continuous spinal anesthesia with a microcatheter technique: preliminary experience. , 1990, Anesthesia and analgesia.

[13]  S. Hunter,et al.  Combined Doppler and echocardiographic measurement of cardiac output: theory and application in pregnancy , 1987, British journal of obstetrics and gynaecology.

[14]  B. Trudinger,et al.  A comparison of fetal heart rate monitoring and umbilical artery waveforms in the recognition of fetal compromise , 1986, British journal of obstetrics and gynaecology.

[15]  D. I. Edelstone,et al.  Fetal Acid—Base State Following Spinal or Epidural Anesthesia for Cesarean Section , 1980, Obstetrics and gynecology.

[16]  W. T. Lemmon,et al.  Continuous—Serial, Freational, Controllable, Intermittent—Spinal Anesthesiawith Observations on 1000 Cases , 1942 .