Comparative assessment of the corrosion process of orthodontic archwires made of stainless steel, titanium–molybdenum and nickel–titanium alloys

Abstract The phenomenon of corrosion of orthodontic appliances is of interest to both clinicians and researchers dealing with the issue of biocompatibility of medical materials. The oral cavity, due to its temperature fluctuations, changing pH, high humidity, action of mechanical forces and the presence of microorganisms is a favorable environment for degradation of dental materials. This article presents the comparative assessment of the intensity of corrosion of orthodontic archwires made of alloy steel, nickel–titanium and titanium–molybdenum alloys in laboratory conditions. Corrosion resistance examinations were carried out by means of the impedance and the potentiodynamic methods using an Autolab PGSTAT100 potentiostat/galwanostat (Eco Chemie B.V., Holand) with FRA2 module, in non-deaerated artificial saliva solution at 37 °C. An analysis of the impendence method's data showing that the highest corrosion resistance is observed for NiTi arches (3M, USA), while the lowest resistance for SS arches (3M, USA). These observations were confirmed by the data obtained from potentiodynamic tests; it was observed that the average corrosion current density [Icor] was the lowest for nickel–titanium archwires (3M, USA) and averaged 2.50 × 10−3 μA/cm2. The highest Icor corrosion current was observed in the case of steel wires from the same manufacturer and averaged 4.96 × 10−2 μA/cm2.

[1]  J T Watts,et al.  Intra-oral temperature variation over 24 hours. , 1999, European journal of orthodontics.

[2]  D. Berzins,et al.  Corrosion behavior of shape memory, superelastic, and nonsuperelastic nickel-titanium-based orthodontic wires at various temperatures. , 2008, Dental materials : official publication of the Academy of Dental Materials.

[3]  Aderval S. Luna,et al.  Corrosion evaluation of orthodontic wires in artificial saliva solutions by using response surface methodology , 2012 .

[4]  Marcelo do Amaral Ferreira,et al.  Nickel-titanium alloys: a systematic review , 2012 .

[5]  K. Vinay,et al.  Comparison of Galvanic Currents Generated Between Different Combinations of Orthodontic Brackets and Archwires Using Potentiostat: An In Vitro Study , 2015, Journal of international oral health : JIOH.

[6]  C. Bourauel,et al.  In-vitro evaluation of the corrosion behavior of orthodontic brackets. , 2009, Orthodontics & craniofacial research.

[7]  F. Heravi,et al.  GALVANIC CORROSION AMONG DIFFERENT COMBINATION OF ORTHODONTIC ARCHWIRES AND STAINLESS STEEL BRACKETS , 2014 .

[8]  T. Chaturvedi,et al.  An overview of orthodontic material degradation in oral cavity. , 2010, Indian journal of dental research : official publication of Indian Society for Dental Research.

[9]  A. Vicente,et al.  Metallic ion content and damage to the DNA in oral mucosa cells of children with fixed orthodontic appliances , 2011, BioMetals.

[10]  J. Bánóczy,et al.  The Role of Electrical Potential Differences in the Etiology of Chronic Diseases of the Oral Mucosa , 1961 .

[11]  J. Sandy,et al.  Corrosion of orthodontic appliances--should we care? , 2008, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[12]  M. Pakshir,et al.  In vitro evaluation of the electrochemical behaviour of stainless steel and Ni-Ti orthodontic archwires at different temperatures. , 2013, European journal of orthodontics.

[13]  F. Gil,et al.  Influence of the microstructure on electrochemical corrosion and nickel release in NiTi orthodontic archwires. , 2013, Materials science & engineering. C, Materials for biological applications.

[14]  J. L. Drury,et al.  Nickel alloys in the oral environment , 2013, Expert review of medical devices.

[15]  D. Semenski,et al.  Influence of surface layer on mechanical and corrosion properties of nickel-titanium orthodontic wires. , 2014, The Angle orthodontist.

[16]  Rama Krishna Alla,et al.  An Overview of Orthodontic Wires , 2014 .

[17]  T. G. Bradley,et al.  Galvanic corrosion between various combinations of orthodontic brackets and archwires. , 2011, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[18]  M. Jenko,et al.  The corrosion behaviour of austenitic and duplex stainless steels in artificial saliva with the addition of fluoride , 2011 .

[19]  T. Otsuka,et al.  Development of the aesthetic orthodontic appliances using a silver plating process: the report on peel resistance , 2017 .

[20]  V. Arora,et al.  Corrosion resistance of surface modified nickel titanium archwires. , 2014, The Angle orthodontist.

[21]  Javier Gil,et al.  In Vitro Corrosion Behavior of Lingual Orthodontic Archwires , 2011 .

[22]  K. Chojnacka,et al.  Release of Metal Ions from Orthodontic Appliances by In Vitro Studies: A Systematic Literature Review , 2011, Biological Trace Element Research.

[23]  A. Ruellas,et al.  Influence of optical properties of esthetic brackets (color, translucence, and fluorescence) on visual perception. , 2012, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.