Digital Images, Mathematical Modeling And Physiological Parameters
暂无分享,去创建一个
An iterative method for the determination of the start and end of the tracer flow through a compartment was developed and used to create a digital image of the compartment of interest. This digital image was then used to select a region-of-interest corresponding to a selected compartment. Dynamic curves were corrected for background, dead time, and for possible overlapping of different physiological compartments. The shape of the corrected curves was then compared with expected behavior of the tracer in a compartment. On the basis of the physiological considerations, mathematical models are developed. Once the mathematical model is developed, the experimental data is used as suggested by the model. We applied these general considerations to the studies of the heart, lungs, kidneys and hepatobiliary system.
[1] H. Anger,et al. Cardiac evaluation from radioisotope dynamics. , 1972, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[2] Z. Bajzer,et al. Lung ventilation model for radioactive tracer itdal breathing. , 1980, Physics in medicine and biology.
[3] Š. Spaventi,et al. The Use of 81mKr Gas for the Measurement of Absolute Regional Lung Ventilation , 1977, Nuklearmedizin.