High-brightness, high-power LED-based strobe illumination for double-frame micro particle image velocimetry

Abstract There is a need for more practical, cost-effective and adaptive flow measurement instruments. Unfortunately, most of the current equipment still has to employ bulky and expensive laser systems for flow illumination. In this work we explore the practicability of using high-brightness high-power light-emitting diodes (LED) as a strobe-light illuminator within a double-frame micro particle image velocimetry (microPIV) system. A compact, cost-effective, and controllable LED driver was designed and applied to study the optical and spectral behavior of green and blue family direct-color single chip LEDs, which have excitation wavelengths corresponding to the most widely used fluorescent micro particles. To achieve strobe illumination, LEDs were subjected to high current double-pulsed operating regimes (up to 35 A at 20 μs pulse duration), which are much beyond their physical damage thresholds. We have witnessed that the blue family LEDs are more suitable for the fluorescence based microPIV experiments as they exhibit more stable spectral behavior at the double-pulsed high currents compared to the green colored LEDs. Specifically, we have observed that the spectral wavelength shift of blue family LEDs due to the high current is less severe and still enough to excite particles than that of green LEDs. Also, we have studied the relation between the pulse duration (as a means of parameter controlling signal-to-noise ratio) and the motion blur effect that arises due to the prolonged pulse durations. As a result, adequate pulse durations for most widely used microPIV experimental conditions were calculated. The feasibility and robustness of the developed double-pulsed LED illumination system was validated through a series of microPIV experiments with real flows inside two different topology microchannels, where the measured velocity was in good agreement with the corresponding analytical solutions. Overall, we can conclude that the high-brightness LED devices are promising candidates to replace their laser counterparts in the microPIV systems.

[1]  D. Beebe,et al.  A particle image velocimetry system for microfluidics , 1998 .

[2]  M. Mouqallid,et al.  CCD Recording method for cross-correlation PIV development in unstationary high speed flow , 1994 .

[3]  C. Willert,et al.  Tomographic shadowgraphy for three-dimensional reconstruction of instantaneous spray distributions , 2012 .

[4]  Daoyi Chen,et al.  The development of an automated PIV image processing software—SmartPIV , 2011 .

[5]  Y. Sugii,et al.  In vivo PIV measurement of red blood cell velocity field in microvessels considering mesentery motion. , 2002, Physiological measurement.

[6]  Barton L. Smith,et al.  Uncertainty on PIV mean and fluctuating velocity due to bias and random errors , 2013 .

[7]  C. Meinhart,et al.  Quantum nanospheres for sub-micron particle image velocimetry , 2007 .

[8]  A. I. Zhmakin Enhancement of light extraction from light emitting diodes , 2011 .

[9]  R. Adrian,et al.  Transition from laminar to turbulent flow in liquid filled microtubes , 2004 .

[10]  Eberhard Bodenschatz,et al.  Limitations of accuracy in PIV due to individual variations of particle image intensities , 2009 .

[11]  Martin Sommerfeld,et al.  Planar shadow image velocimetry for the analysis of the hydrodynamics in bubbly flows , 2007 .

[12]  Pentti Saarenrinne,et al.  Digital imaging measurement of dense multiphase flows in industrial processes , 2010 .

[13]  J. Kutter,et al.  Investigations on LED illumination for micro-PIV including a novel front-lit configuration , 2008 .

[14]  Julio Soria,et al.  Pulsed, high-power LED illumination for tomographic particle image velocimetry , 2012 .

[15]  G. Kim,et al.  Development of a compact x-ray particle image velocimetry for measuring opaque flows. , 2009, The Review of scientific instruments.

[16]  R. Dupuis,et al.  History, Development, and Applications of High-Brightness Visible Light-Emitting Diodes , 2008, Journal of Lightwave Technology.

[17]  Bernhard Wieneke,et al.  PIV uncertainty quantification by image matching , 2013 .

[18]  Ray W.K. Allen,et al.  Micro-PIV simulation and measurement in complex microchannel geometries , 2005 .

[19]  S. Wereley,et al.  A PIV Algorithm for Estimating Time-Averaged Velocity Fields , 2000 .

[21]  Z. Silber-Li,et al.  Measurement of velocity profiles in a rectangular microchannel with aspect ratio α = 0.35 , 2008 .

[22]  Adalat Nasibov,et al.  Performance Analysis of the CCD Pixel Binning Option in Particle-Image Velocimetry Measurements , 2010, IEEE/ASME Transactions on Mechatronics.

[23]  M. Craford,et al.  Status and Future of High-Power Light-Emitting Diodes for Solid-State Lighting , 2007, Journal of Display Technology.

[24]  Anton Vernet,et al.  Small-scale characteristics and turbulent statistics of the flow in an external gear pump by time-resolved PIV , 2013 .

[25]  A. M. Fincham,et al.  Low cost, high resolution DPIV for measurement of turbulent fluid flow , 1997 .

[26]  R. Adrian,et al.  Effect of resolution on the speed and accuracy of particle image velocimetry interrogation , 1992 .

[27]  Yue Lin,et al.  Study of temperature sensitive optical parameters and junction temperature determination of light-emitting diodes , 2012 .

[28]  Adalat Nasibov,et al.  A PIV dynamic velocity range enhancement approach using ROI option of imaging sensors , 2012 .

[29]  S. Lee,et al.  Advanced particle-based velocimetry techniques for microscale flows , 2009 .

[30]  Richard D. Keane,et al.  Theory of cross-correlation analysis of PIV images , 1992 .

[31]  R. Adrian,et al.  Brownian motion and correlation in particle image velocimetry , 2000 .

[32]  Julio Soria,et al.  An assessment of high-power light-emitting diodes for high frame rate schlieren imaging , 2012 .

[33]  T. Bayraktar,et al.  Characterization of liquid flows in microfluidic systems , 2006 .

[34]  C. Willert,et al.  Digital particle image velocimetry , 1991 .

[35]  Donald W. Knight,et al.  The application of LS-PIV to a small irregular river for inbank and overbank flows , 2012 .

[36]  J. Wells,et al.  Velocity measurement of near-wall flow over inclined and curved boundaries by extended interfacial particle image velocimetry , 2012 .

[37]  R. Adrian Twenty years of particle image velocimetry , 2005 .

[38]  S. Wereley,et al.  PIV measurements of a microchannel flow , 1999 .

[39]  Suresh V. Garimella,et al.  Infrared Micro-Particle Image Velocimetry Measurements and Predictions of Flow Distribution in a Microchannel Heat Sink * , 2008 .

[40]  Ruggero Pintus,et al.  High brightness GaN LEDs degradation during dc and pulsed stress , 2006, Microelectron. Reliab..

[41]  Miran Bürmen,et al.  LED light sources: a survey of quality-affecting factors and methods for their assessment , 2008 .

[42]  S. Wereley,et al.  Particle imaging techniques for microfabricated fluidic systems , 2003 .

[43]  T. Ishikawa,et al.  In vitro blood flow in a rectangular PDMS microchannel: experimental observations using a confocal micro-PIV system , 2008, Biomedical microdevices.

[44]  Tobias Meyer,et al.  New developments in green LEDs , 2009 .

[45]  Holger Nobach,et al.  Two-dimensional Gaussian regression for sub-pixel displacement estimation in particle image velocimetry or particle position estimation in particle tracking velocimetry , 2005 .

[46]  Christian Willert,et al.  Pulsed operation of high-power light emitting diodes for imaging flow velocimetry , 2010 .

[47]  Cam Tropea,et al.  High-precision sub-pixel interpolation in particle image velocimetry image processing , 2005 .

[48]  Microfluidic image cytometry for measuring number and sizes of biological cells flowing through a microchannel using the micro-PIV technique , 2008 .

[49]  Willem van Driel,et al.  Degradation of light emitting diodes: a proposed methodology , 2011 .

[50]  V. Semião,et al.  Micro-PIV and CFD characterization of flows in a microchannel: Velocity profiles, surface roughness and Poiseuille numbers , 2008 .

[51]  J. Nogueira,et al.  PIV evaluation algorithms for industrial applications , 2004 .

[52]  L. Peternai,et al.  Advanced light emitting diodes structures for optoelectronic applications , 2003 .

[53]  Olivier Chételat,et al.  Miniature particle image velocimetry system with LED in-line illumination , 2002 .

[54]  Morteza Gharib,et al.  Leonardo's vision of flow visualization , 2002 .

[55]  Vanessa Egan,et al.  A statistical analysis for time-averaged turbulent and fluctuating flow fields using Particle Image Velocimetry , 2012 .

[56]  G. Chen,et al.  Performance of high‐power III‐nitride light emitting diodes , 2008 .

[57]  Ala Hijazi,et al.  A novel ultra-high speed camera for digital image processing applications , 2008 .

[58]  L. Lourenço Particle Image Velocimetry , 1989 .

[59]  Jerry Westerweel,et al.  Micro-Particle Image Velocimetry (microPIV): recent developments, applications, and guidelines. , 2009, Lab on a chip.

[60]  M. Meneghini,et al.  A Review on the Reliability of GaN-Based LEDs , 2008, IEEE Transactions on Device and Materials Reliability.