Wide-Cone Angle Phase-Contrast X-Ray Computed Tomography of Synthetic Polymer Materials

X-ray phase-contrast imaging (PCI) is sensitive to the phase shift of X-rays induced by the sample. This is advantageous for low X-ray absorption samples, such as polymers, biomaterials, tissues, and scaffolds. We show propagation-based phase-contrast X-ray computed tomography (CT) imaging [propagation-based imaging (PBI)] in a specific configuration with the wide-cone angle (>50°), polychromatic X-ray source, and a flat-panel detector. We demonstrate PBI on measurements with a polymer composite. The experiments show a tradeoff between high signal-to-noise ratio (SNR) acquisition at very large cone angles and low-SNR acquisition at large propagation distances. The degree of data quality improvement by phase retrieval increases for high propagation distances. We show the application of PBI on macroporous synthetic hydrogels, which represents an important type of material with a complex 3-D morphology in the field of polymer science. With the use of the above-described experimental configuration, it is possible to visualize the hydrogels and segment the structure of the sample in tomographic data. The segmented sample can be used for morphology characterization, such as the description of internal space or determination of specific surface area (SSA).

[1]  Miriam C. Strumia,et al.  Macroporous poly(EGDMA-co-HEMA) networks: Morphological characterization from their behaviour in the swelling process , 2012 .

[2]  T Takeda,et al.  Phase-Contrast Tomographic Imaging Using an X-ray Interferometer. , 1998, Journal of synchrotron radiation.

[3]  Frantisek Svec,et al.  Poly(2-hydroxyethyl acrylate-co-ethyleneglycol dimethacrylate) monoliths synthesized by radiation polymerization in a mold , 2007 .

[4]  Anna Burvall,et al.  Phase Retrieval in X-ray Phase-contrast Imaging Suitable for Tomography , 2022 .

[5]  Andrew W. Stevenson,et al.  In-Line Phase-Contrast X-ray Imaging and Tomography for Materials Science , 2012, Materials.

[6]  L Sprincl,et al.  Effect of porosity of heterogeneous poly(glycol monomethacrylate) gels on the healing-in of test implants. , 1971, Journal of biomedical materials research.

[7]  Kazuyuki Hyodo,et al.  High-energy phase-contrast X-ray imaging using a two-crystal X-ray interferometer. , 2005, Journal of synchrotron radiation.

[8]  Axel Habicht,et al.  Energy Consumption for the Desalination of Salt Water Using Polyelectrolyte Hydrogels as the Separation Agent , 2017 .

[9]  P. Cloetens,et al.  Imaging applications of synchrotron X‐ray phase‐contrast microtomography in biological morphology and biomaterials science. I. General aspects of the technique and its advantages in the analysis of millimetre‐sized arthropod structure , 2007, Journal of microscopy.

[10]  Hongtao Cui,et al.  X-ray computed tomography in Zernike phase contrast mode at 8 keV with 50-nm resolution using Cu rotating anode X-ray source , 2007 .

[11]  P. Withers,et al.  X-ray computed tomography of polymer composites , 2017 .

[12]  Paola Coan,et al.  Analyzer-based imaging technique in tomography of cartilage and metal implants: a study at the ESRF. , 2008, European journal of radiology.

[13]  P. C. Diemoz,et al.  Sensitivity of laboratory based implementations of edge illumination X-ray phase-contrast imaging , 2013 .

[14]  Libor Matějka,et al.  Insight into the cryopolymerization to form a poly(N-isopropylacrylamide)/clay macroporous gel: structure and phase evolution. , 2017, Soft matter.

[15]  Miroslava Dušková-Smrčková,et al.  The Manifold Varieties of Poly(2‐Hydroxyethyl Methacrylate) Hydrogels−IPNs , 2017 .

[16]  Heyang Li,et al.  Space-Filling X-Ray Source Trajectories for Efficient Scanning in Large-Angle Cone-Beam Computed Tomography , 2018, IEEE Transactions on Computational Imaging.

[17]  Martin Schneebeli,et al.  Measuring the specific surface area of snow with X-ray tomography and gas adsorption: comparison and implications for surface smoothness , 2007 .

[18]  Philip J. Withers,et al.  An examination of phase retrieval algorithms as applied to phase contrast tomography using laboratory sources , 2010, Optical Engineering + Applications.

[19]  Tim Salditt,et al.  Laboratory-based x-ray phase-contrast tomography enables 3D virtual histology , 2016, Optical Engineering + Applications.

[20]  P J Withers,et al.  A comparison of different approaches for imaging cracks in composites by X-ray microtomography , 2016, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[21]  Miroslav Šlouf,et al.  Porous hybrid poly(N-isopropylacrylamide) hydrogels with very fast volume response to temperature and pH , 2019, European Polymer Journal.

[22]  S. Woerly,et al.  Interactions of copolymeric poly(glyceryl methacrylate)-collagen hydrogels with neural tissue: effects of structure and polar groups. , 1991, Biomaterials.

[23]  Jiří Michálek,et al.  Macroporous 2-hydroxyethyl methacrylate hydrogels of dual porosity for cell cultivation: morphology, swelling, permeability, and mechanical behavior , 2014, Journal of Polymer Research.

[24]  S. Wilkins,et al.  Phase-contrast imaging using polychromatic hard X-rays , 1996, Nature.

[25]  Hong Liu,et al.  Phase-contrast X-ray tomography: contrast mechanism and roles of phase retrieval. , 2008, European journal of radiology.

[26]  Hong Liu,et al.  Impact of focal spot size on the spatial resolution of a digital x-ray imaging system for small-animal studies , 2002, SPIE BiOS.

[27]  Miroslav Šlouf,et al.  Rheology and porosity control of poly(2-hydroxyethyl methacrylate) hydrogels , 2013 .

[28]  Franz Pfeiffer,et al.  Soft-tissue phase-contrast tomography with an x-ray tube source , 2009, Physics in medicine and biology.

[29]  Wah-Keat Lee,et al.  Real-time phase-contrast x-ray imaging: a new technique for the study of animal form and function , 2007, BMC Biology.

[30]  Traian V. Chirila,et al.  Laser scanning confocal microscopy versus scanning electron microscopy for characterization of polymer morphology: Sample preparation drastically distorts morphologies of poly(2-hydroxyethyl methacrylate)-based hydrogels , 2013 .

[31]  Hong Liu,et al.  Clarification of aspects in in-line phase-sensitive x-ray imaging. , 2007, Medical physics.

[32]  Hana Macková,et al.  Reductively Degradable Poly(2-hydroxyethyl methacrylate) Hydrogels with Oriented Porosity for Tissue Engineering Applications. , 2017, ACS applied materials & interfaces.

[33]  S. J. Peighambardoust,et al.  A review on acrylic based hydrogels and their applications in wastewater treatment. , 2018, Journal of environmental management.

[34]  Francesca Cosmi,et al.  Phase contrast micro-tomography and morphological analysis of a short carbon fibre reinforced polyamide , 2011 .

[35]  Yoshihiro Takeda,et al.  Characterization of a Laboratory-Based X-Ray Computed Nanotomography System for Propagation-Based Method of Phase Contrast Imaging , 2020, IEEE Transactions on Instrumentation and Measurement.

[36]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[37]  Johann Kastner,et al.  Non-destructive characterisation of polymers and Al-alloys by polychromatic cone-beam phase contrast tomography , 2012 .

[38]  Miroslav Šlouf,et al.  Synthesis of conductive doubly filled poly(N-isopropylacrylamide)-polyaniline-SiO2 hydrogels , 2017 .

[39]  E. Pisano,et al.  Diffraction enhanced x-ray imaging. , 1997, Physics in medicine and biology.

[40]  Ian Constable,et al.  Hydrophilic sponges based on 2−hydroxyethyl methacrylate. I: Effect of monomer mixture composition on the pore size , 1993 .

[41]  S. Wilkins,et al.  Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object , 2002, Journal of microscopy.

[42]  Anders Brahme,et al.  Development of phase-contrast X-ray imaging techniques and potential medical applications. , 2008, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[43]  Torsten Remmler,et al.  Rheological properties of homogeneous and heterogeneous poly(2-hydroxyethyl methacrylate) hydrogels , 2012 .

[44]  F Arfelli,et al.  Theory and preliminary experimental verification of quantitative edge illumination x-ray phase contrast tomography. , 2014, Optics express.