Real-time pose estimation of devices from x-ray images: Application to x-ray/echo registration for cardiac interventions

In recent years, registration between x-ray fluoroscopy (XRF) and transesophageal echocardiography (TEE) has been rapidly developed, validated, and translated to the clinic as a tool for advanced image guidance of structural heart interventions. This technology relies on accurate pose-estimation of the TEE probe via standard 2D/3D registration methods. It has been shown that latencies caused by slow registrations can result in errors during untracked frames, and a real-time ( > 15 hz) tracking algorithm is needed to minimize these errors. This paper presents two novel similarity metrics designed for accurate, robust, and extremely fast pose-estimation of devices from XRF images: Direct Splat Correlation (DSC) and Patch Gradient Correlation (PGC). Both metrics were implemented in CUDA C, and validated on simulated and clinical datasets against prior methods presented in the literature. It was shown that by combining DSC and PGC in a hybrid method (HYB), target registration errors comparable to previously reported methods were achieved, but at much higher speeds and lower failure rates. In simulated datasets, the proposed HYB method achieved a median projected target registration error (pTRE) of 0.33 mm and a mean registration frame-rate of 12.1 hz, while previously published methods produced median pTREs greater than 1.5 mm and mean registration frame-rates less than 4 hz. In clinical datasets, the HYB method achieved a median pTRE of 1.1 mm and a mean registration frame-rate of 20.5 hz, while previously published methods produced median pTREs greater than 1.3 mm and mean registration frame-rates less than 12 hz. The proposed hybrid method also had much lower failure rates than previously published methods.

[1]  Jürgen Weese,et al.  A comparison of similarity measures for use in 2-D-3-D medical image registration , 1998, IEEE Transactions on Medical Imaging.

[2]  Terry M. Peters,et al.  US–Fluoroscopy Registration for Transcatheter Aortic Valve Implantation , 2012, IEEE Transactions on Biomedical Engineering.

[3]  YingLiang Ma,et al.  Evaluation of a Real-Time Hybrid Three-Dimensional Echo and X-Ray Imaging System for Guidance of Cardiac Catheterisation Procedures , 2012, MICCAI.

[4]  Wolfgang Birkfellner,et al.  Wobbled splatting—a fast perspective volume rendering method for simulation of x-ray images from CT , 2005, Physics in medicine and biology.

[5]  Michael A. Speidel,et al.  Robust 5DOF Transesophageal Echo Probe Tracking at Fluoroscopic Frame Rates , 2015, MICCAI.

[6]  Kawal S. Rhode,et al.  Rapid Image Registration of Three-Dimensional Transesophageal Echocardiography and X-ray Fluoroscopy for the Guidance of Cardiac Interventions , 2010, IPCAI.

[7]  Michael A. Speidel,et al.  Hough Forests for Real-Time, Automatic Device Localization in Fluoroscopic Images: Application to TAVR , 2015, MICCAI.

[8]  Bostjan Likar,et al.  A review of 3D/2D registration methods for image-guided interventions , 2012, Medical Image Anal..

[9]  Peter Mountney,et al.  Real-time ultrasound transducer localization in fluoroscopy images by transfer learning from synthetic training data , 2014, Medical Image Anal..

[10]  Nassir Navab,et al.  6DoF Catheter Detection, Application to Intracardiac Echocardiography , 2014, MICCAI.

[11]  Antonio Colombo,et al.  Optimal imaging for guiding TAVR: transesophageal or transthoracic echocardiography, or just fluoroscopy? , 2015, JACC. Cardiovascular imaging.

[12]  YingLiang Ma,et al.  Registration of 3D trans-esophageal echocardiography to X-ray fluoroscopy using image-based probe tracking , 2012, Medical Image Anal..

[13]  William M. Wells,et al.  Medical Image Computing and Computer-Assisted Intervention — MICCAI’98 , 1998, Lecture Notes in Computer Science.

[14]  Guido Gerig,et al.  User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliability , 2006, NeuroImage.

[15]  Douglas Stanton,et al.  3D TEE Registration with X-Ray Fluoroscopy for Interventional Cardiac Applications , 2009, FIMH.

[16]  Gabor Fichtinger,et al.  Monitoring tumor motion by real time 2D/3D registration during radiotherapy , 2012, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[17]  Dorin Comaniciu,et al.  Ultrasound and Fluoroscopic Images Fusion by Autonomous Ultrasound Probe Detection , 2012, MICCAI.