Online NIR Analysis and Prediction Model for Synthesis Process of Ethyl 2-Chloropropionate

Online near-infrared spectroscopy was used as a process analysis technique in the synthesis of 2-chloropropionate for the first time. Then, the partial least squares regression (PLSR) quantitative model of the product solution concentration was established and optimized. Correlation coefficient (R 2) of partial least squares regression (PLSR) calibration model was 0.9944, and the root mean square error of correction (RMSEC) was 0.018105 mol/L. These values of PLSR and RMSEC could prove that the quantitative calibration model had good performance. Moreover, the root mean square error of prediction (RMSEP) of validation set was 0.036429 mol/L. The results were very similar to those of offline gas chromatographic analysis, which could prove the method was valid.

[1]  Haoshu Xiong,et al.  Monitoring batch-to-batch reproducibility of liquid-liquid extraction process using in-line near-infrared spectroscopy combined with multivariate analysis. , 2012, Journal of pharmaceutical and biomedical analysis.

[2]  James K. Drennen,et al.  Near-Infrared Spectroscopy: Applications in the Analysis of Tablets and Solid Pharmaceutical Dosage Forms , 1995 .

[3]  James P. Collman,et al.  A quantitative UV–VIS probe of enantioselectivity in metalloporphyrin catalyzed oxygenation using aluminium model complexes , 1999 .

[4]  A. Pierre,et al.  FT-NIR spectroscopy: Trends and application to the kinetic study of epoxy/triamine system (comparison with DSC and SEC results) , 1996 .

[5]  Ning Wang,et al.  Quantitative Analysis of Adulterations in Oat Flour by FT-NIR Spectroscopy, Incomplete Unbalanced Randomized Block Design, and Partial Least Squares , 2014, Journal of analytical methods in chemistry.

[6]  Xue-song Liu,et al.  NIR spectroscopy as a process analytical technology (PAT) tool for on-line and real-time monitoring of an extraction process , 2012 .

[7]  Desire L. Massart,et al.  Using contrasts as data pretreatment method in pattern recognition of multivariate data , 1999 .

[8]  Rainer Künnemeyer,et al.  Internal Quality Assessment of Mandarin Fruit by vis/NIR Spectroscopy , 2003 .

[9]  W. Fred McClure,et al.  Near infrared spectroscopy : the giant is running strong , 1994 .

[10]  Hai Qing Yang,et al.  Nondestructive Prediction of Optimal Harvest Time of Cherry Tomatoes Using VIS-NIR Spectroscopy and PLSR Calibration , 2011 .

[11]  J. Engelbrecht,et al.  Acetone to MIBK process optimization through multidisciplinary chemometrics and in-line NIR spectroscopy , 2008 .

[12]  W. Marsden I and J , 2012 .

[13]  Qun Ma,et al.  NIR spectroscopy as a process analytical technology (PAT) tool for monitoring and understanding of a hydrolysis process. , 2013, Bioresource technology.

[14]  René Gislum,et al.  Quantification of fructan concentration in grasses using NIR spectroscopy and PLSR , 2011 .

[15]  Yizeng Liang,et al.  Preprocessing of analytical profiles in the presence of homoscedastic or heteroscedastic noise , 1994 .

[16]  Jiemei Chen,et al.  Vis-NIR wavelength selection for non-destructive discriminant analysis of breed screening of transgenic sugarcane , 2014 .

[17]  Helena Pereira,et al.  Kappa Number Prediction of Acacia melanoxylon Unbleached Kraft Pulps using NIR-PLSR Models with a Narrow Interval of Variation , 2014 .

[18]  E. V. Thomas,et al.  Partial least-squares methods for spectral analyses. 1. Relation to other quantitative calibration methods and the extraction of qualitative information , 1988 .

[19]  Bjørn-Helge Mevik,et al.  Mean squared error of prediction (MSEP) estimates for principal component regression (PCR) and partial least squares regression (PLSR) , 2004 .

[20]  Helena Pereira,et al.  NIR PLSR results obtained by calibration with noisy, low-precision reference values: Are the results acceptable? , 2006 .

[21]  Nathalie Dupuy,et al.  Chemometric analysis of combined NIR and MIR spectra to characterize French olives , 2010 .

[22]  H. Martens,et al.  Modified Jack-knife estimation of parameter uncertainty in bilinear modelling by partial least squares regression (PLSR) , 2000 .

[23]  José C Menezes,et al.  Near-infrared reflectance spectroscopy as a process analytical technology tool in Ginkgo biloba extract qualification. , 2008, Journal of pharmaceutical and biomedical analysis.