An arrayed waveguide grating based multiplexer and interrogator for Fabry-Perot sensors

In this paper, we propose an interrogation system capable of multiplexing four identical Fabry-Perot (FP) interferometric sensors using two wavelength-division multiplexing devices. One is a 40-channel DWDM channel monitor, the other a four-channel CWDM device. The sensors are connected to the output channels of the CWDM device in order to assign a portion of the spectrum to each sensor. The reflected spectra are then analyzed using the DWDM channel monitor. By monitoring the power incident on each of the DWDM channels, the four sensor reflection spectra can be reconstructed in software and information relating to the measurand obtained. Based on software simulations and previous laboratory experiments with single sensors, it is predicted that this system would be capable of interrogating four EFPI strain sensors simultaneously at frequencies greater than 5 kHz with a resolution of approximately 2 /spl mu//spl epsiv/ and a range of 3000 /spl mu//spl epsiv/.

[1]  Alan D. Kersey,et al.  Interrogation and multiplexing techniques for fiber Bragg grating strain sensors , 1993, Other Conferences.

[2]  L. Reekie,et al.  Novel interrogating system for fibre Bragg grating sensors using an acousto-optic tunable filter , 1993 .

[3]  John P. Dakin,et al.  Discrimination between strain and temperature effects using dual-wavelength fibre grating sensors , 1994 .

[4]  Michael A. Davis,et al.  Fiber grating sensors , 1997 .

[5]  Yasukazu Sano Wavelength interrogator employing arrayed waveguide grating for distributed fiber Bragg grating sensors , 2000, International Conference on Optical Fibre Sensors.

[6]  Grzegorz Fusiek,et al.  Interrogation of extrinsic Fabry-Perot interferometric sensors using arrayed waveguide grating devices , 2002, IMTC/2002. Proceedings of the 19th IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.00CH37276).

[7]  Pawel Niewczas,et al.  Performance analysis of the Fiber Bragg grating Interrogation system based on an arrayed waveguide grating , 2003, Proceedings of the 20th IEEE Instrumentation Technology Conference (Cat. No.03CH37412).

[8]  T. Yoshino,et al.  Fast optical wavelength interrogator employing arrayed waveguide grating for distributed fiber Bragg grating sensors , 2003 .

[9]  Pawel Niewczas,et al.  Performance analysis of the fiber Bragg grating interrogation system based on an arrayed waveguide grating , 2004, IEEE Transactions on Instrumentation and Measurement.

[10]  Grzegorz Fusiek,et al.  Dynamic strain measurement using an extrinsic Fabry-Perot interferometric sensor and an arrayed waveguide grating device , 2004, IEEE Transactions on Instrumentation and Measurement.