Verifying interoperability and application performance of PMUs and PMU-enabled IEDs

This paper presents a new test methodology for verifying the interoperability and application performance of PMUs and PMU-enabled IEDs at the device and system level. Two types of tests are defined to evaluate the performance of synchrophasor devices from two different aspects: design and application. The interoperability between PMUs, time synchronization options, and phasor data concentrators (PDCs) can be verified by design test methodology. A fault location algorithm using two-end synchronized measurements is used to evaluate the application performance. A reference PMU algorithm and synchrophasor system test set-up have been developed to perform the tests. Nine commercial PMUs and four GPS receivers with different synchronization options are selected to perform the tests. The test results are summarized at the end.

[1]  Gerard N. Stenbakken Calculating combined amplitude and phase modulated power signal parameters , 2011, 2011 IEEE Power and Energy Society General Meeting.

[2]  A.G. Phadke,et al.  Comparative testing of synchronized phasor measurement units , 2004, IEEE Power Engineering Society General Meeting, 2004..

[3]  A. Abur,et al.  Robust Measurement Design by Placing Synchronized Phasor Measurements on Network Branches , 2010, IEEE Transactions on Power Systems.

[4]  Z.A. Styczynski,et al.  Practical Experience with PMU System Testing and Calibration Requirements , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[5]  B. Vandiver,et al.  Testing of Phasor Measurement Units , 2010, 2010 63rd Annual Conference for Protective Relay Engineers.

[6]  Ruisheng Diao,et al.  Decision Tree-Based Online Voltage Security Assessment Using PMU Measurements , 2009, IEEE Transactions on Power Systems.

[7]  P. Forsyth,et al.  Large scale power system simulation and PMU testing using a real time digital simulator , 2007, 2007 International Power Engineering Conference (IPEC 2007).

[8]  E. Kyriakides,et al.  PMU Measurement Uncertainty Considerations in WLS State Estimation , 2009, IEEE Transactions on Power Systems.

[9]  James S. Thorp,et al.  IEEE Standard for Synchrophasors for Power Systems , 1998 .

[10]  Vladimir Terzija,et al.  Setup of the laboratory for Synchronized Measurement for PMU's testing , 2009, 2009 IEEE Bucharest PowerTech.

[11]  James S. Thorp,et al.  Synchronized Phasor Measurement Applications in Power Systems , 2010, IEEE Transactions on Smart Grid.

[12]  Kenneth E. Martin,et al.  Standardized Testing of Phasor Measurement Units , 2006 .

[13]  F. Ashcroft,et al.  VIII. References , 1955 .

[14]  Yi Hu,et al.  Progresses in PMU testing and calibration , 2008, 2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies.

[15]  Mladen Kezunovic,et al.  Characterizing dynamic behavior of PMUs using step signals , 2011 .

[16]  Zhenyu Huang,et al.  Performance evaluation of phasor measurement systems , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[17]  Zhiying Zhang,et al.  Calibration and testing of TESLA Phasor Measurement Unit (PMU) using doble F6150 test instrument , 2007, 2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability.

[18]  W.A. Mittelstadt,et al.  Use of the WECC WAMS in Wide-Area Probing Tests for Validation of System Performance and Modeling , 2009, IEEE Transactions on Power Systems.

[19]  S. Corsi,et al.  A Real-Time Voltage Instability Identification Algorithm Based on Local Phasor Measurements , 2008, IEEE Transactions on Power Systems.