Hand-eye Calibration using Images Restored by Deep Learning

The problem of determining the transformation between the end-effector and the camera attached to the robot arm is called hand-eye calibration. For this calibration, the pose of the robot and the image data of the calibrated camera must be acquired. Since industrial robots use fixed focus cameras, the depth of field is limited, and variable focus lenses cannot determine the camera position or pose with high accuracy because the parameters of the camera change. If the pose of a robot is out of depth of field (DOF), the camera is out of focus, and the image is blurred. If hand-eye calibration is performed using these images, the resulting data includes errors. In this paper, image restoration is performed using deep learning on a blurred image where a marker cannot be found because it is out of focus. This technique is used to sharply restore images and demonstrate a technique for finding markers. We improved the precision of the hand-eye calibration problem by obtaining a clear image restored even in various pose of the robot and reducing the error that occurs in the blurred image.

[1]  Sergio Caccamo,et al.  Optimal least-squares solution to the hand-eye calibration problem , 2020, 2020 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR).

[2]  Mili Shah,et al.  An overview of robot-sensor calibration methods for evaluation of perception systems , 2012, PerMIS.

[3]  Thomas Brox,et al.  U-Net: Convolutional Networks for Biomedical Image Segmentation , 2015, MICCAI.

[4]  Yiu Cheung Shiu,et al.  Calibration of wrist-mounted robotic sensors by solving homogeneous transform equations of the form AX=XB , 1989, IEEE Trans. Robotics Autom..

[5]  Roger Y. Tsai,et al.  A new technique for fully autonomous and efficient 3D robotics hand/eye calibration , 1988, IEEE Trans. Robotics Autom..

[6]  Kostas Daniilidis,et al.  Hand-Eye Calibration Using Dual Quaternions , 1999, Int. J. Robotics Res..

[7]  Michel Dhome,et al.  Hand-eye calibration , 1997, Proceedings of the 1997 IEEE/RSJ International Conference on Intelligent Robot and Systems. Innovative Robotics for Real-World Applications. IROS '97.

[8]  Frank Chongwoo Park,et al.  Robot sensor calibration: solving AX=XB on the Euclidean group , 1994, IEEE Trans. Robotics Autom..

[9]  Emanuele Menegatti,et al.  General Hand–Eye Calibration Based on Reprojection Error Minimization , 2019, IEEE Robotics and Automation Letters.

[10]  Khalil M. Ahmad Yousef,et al.  Solving the robot-world hand-eye(s) calibration problem with iterative methods , 2017, Machine Vision and Applications.

[11]  Danail Stoyanov,et al.  Adjoint Transformation Algorithm for Hand–Eye Calibration with Applications in Robotic Assisted Surgery , 2018, Annals of Biomedical Engineering.