Pump Design for a Portable Renal Replacement System

This work proposes a small, light, valve-less pump design for a portable renal replacement system. By analyzing the working principle of the pump and exploring the design space using an analytical pump model, we developed a novel design for a cam-driven finger pump. Several cams sequentially compress fingers, which compress flexible tubes, thus eliminating valves. Either changing the speed of the motor or size of the tube can control the flow rate. In vitro experiments conducted with whole blood using the pump measured Creatinine levels over time, and the results verify the design for the portable renal replacement system. The proposed pump design is smaller than 153 cm3 and consumes less than 1W while providing a flow rate of more than 100ml/min for both blood and dialysate flows. The smallest pump of a portable renal replacement system in the literature uses check valves, which considerably increase the overall manufacturing cost and possibility of blood clotting. Compared to that pump, the proposed pump design achieved reduction in size by 52% and savings in energy consumption by 89% with the removal of valves. This simple and reliable design substantially reduces the size requirements of a portable renal replacement system.Copyright © 2010 by ASME

[1]  J. C. Olson Design and modeling of a portable hemodialysis system , 2009 .

[2]  D. Ku,et al.  Design of a Portable Renal Replacement System Through Modeling and Experiment , 2009 .

[3]  Asim Nisar,et al.  Three Dimensional Transient Multifield Analysis of a Piezoelectric Micropump for Drug Delivery System for Treatment of Hemodynamic Dysfunctions , 2008, Cardiovascular engineering.

[4]  A. Davenport,et al.  Toward the wearable artificial kidney , 2008, Hemodialysis international. International Symposium on Home Hemodialysis.

[5]  Shuvo Roy,et al.  Development of continuous implantable renal replacement: past and future. , 2007, Translational research : the journal of laboratory and clinical medicine.

[6]  Hans-Dietrich Polaschegg,et al.  Continuous Renal Replacement Therapy for End-Stage Renal Disease , 2005 .

[7]  Hans Köhler,et al.  Dialysis dose and frequency. , 2005, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[8]  H. Polaschegg,et al.  Continuous renal replacement therapy for end-stage renal disease. The wearable artificial kidney (WAK). , 2005, Contributions to nephrology.

[9]  Kyung Hyun Ahn,et al.  Shear induced damage of red blood cells monitored by the decrease of their deformability , 2004 .

[10]  G. Piccoli,et al.  Why Our Patients Like Daily Hemodialysis , 2000, Hemodialysis international. International Symposium on Home Hemodialysis.

[11]  M. Napoli,et al.  Dialysis with increased frequency of sessions (Lecce dialysis). , 1998, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[12]  C. Kjellstrand,et al.  Daily hemodialysis: history and revival of a superior dialysis method. , 1998, ASAIO journal.

[13]  G Naughton,et al.  Tissue engineering: new challenges. , 1998, ASAIO journal.

[14]  J. Daugirdas Second generation logarithmic estimates of single-pool variable volume Kt/V: an analysis of error. , 1993, Journal of the American Society of Nephrology : JASN.

[15]  À. Argilés,et al.  Comparison of hemodialysis and hemodiafiltration: a long-term longitudinal study. , 1992, Kidney international.

[16]  J. D. Hellums,et al.  Physical effects in red blood cell trauma , 1969 .