Pulse sequence for dynamic volumetric imaging of hyperpolarized metabolic products.

Dynamic nuclear polarization and dissolution of a (13)C-labeled substrate enables the dynamic imaging of cellular metabolism. Spectroscopic information is typically acquired, making the acquisition of dynamic volumetric data a challenge. To enable rapid volumetric imaging, a spectral-spatial excitation pulse was designed to excite a single line of the carbon spectrum. With only a single resonance present in the signal, an echo-planar readout trajectory could be used to resolve spatial information, giving full volume coverage of 32 x 32 x 16 voxels every 3.5s. This high frame rate was used to measure the different lactate dynamics in different tissues in a normal rat model and a mouse model of prostate cancer.

[1]  S J Riederer,et al.  Interleaved echo planar imaging on a standard MRI system , 1994, Magnetic resonance in medicine.

[2]  John M Pauly,et al.  Double spin-echo sequence for rapid spectroscopic imaging of hyperpolarized 13C. , 2007, Journal of magnetic resonance.

[3]  J. Ardenkjær-Larsen,et al.  Increase in signal-to-noise ratio of > 10,000 times in liquid-state NMR , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[4]  J Stefan Petersson,et al.  Metabolic imaging and other applications of hyperpolarized 13C1. , 2006, Academic radiology.

[5]  S J Kohler,et al.  In vivo 13carbon metabolic imaging at 3T with hyperpolarized 13C‐1‐pyruvate , 2007, Magnetic resonance in medicine.

[6]  Jan Henrik Ardenkjaer-Larsen,et al.  Metabolic imaging by hyperpolarized 13C magnetic resonance imaging for in vivo tumor diagnosis. , 2006, Cancer research.

[7]  John M Pauly,et al.  Hyperpolarized C‐13 spectroscopic imaging of the TRAMP mouse at 3T—Initial experience , 2007, Magnetic resonance in medicine.

[8]  J. Pauly,et al.  Simultaneous spatial and spectral selective excitation , 1990, Magnetic resonance in medicine.

[9]  Jan H. Ardenkjær-Larsen,et al.  Molecular imaging with endogenous substances , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[10]  Y Zur Design of improved spectral‐spatial pulses for routine clinical use , 2000, Magnetic resonance in medicine.

[11]  M. Thaning,et al.  Real-time metabolic imaging. , 2006, Proceedings of the National Academy of Sciences of the United States of America.

[12]  A Macovski,et al.  Echo‐planar spin‐echo and inversion pulses , 1993, Magnetic resonance in medicine.

[13]  Mathilde H. Lerche,et al.  Generating highly polarized nuclear spins in solution using dynamic nuclear polarization , 2004 .