The Frank Stinchfield Award. 3-Dimensional sliding/contact computational simulation of total hip wear.

Polyethylene wear in total hip replacements is a complex, multifactorial process. A tribologically grounded finite element formulation was developed to make quantitative estimates of polyethylene wear in total hip arthroplasty, incorporating the combined influences of contact stress, sliding distance, and a surface specific wear coefficient. For loading and sliding distance inputs taken directly from human gait data, the computational model showed a strong direct proportionality between femoral head size and volumetric wear rate. Other factors being equal, reducing the thickness of the polyethylene liner led to increases in the computed wear rates, but the effect was far less pronounced than the strong increases in wear rate that accompanied head size increases. Compared with human gait inputs, the load and sliding distance inputs for a 23 degrees biaxial rocking hip simulator led to computed wear rates that were 1.7 times as large, and in which the direction of wear was near the cup apex rather than within the posterosuperolateral quadrant. In general, the finite element model's results emphasize the importance of articulation kinematics, especially sliding distance, in the complex process of polyethylene wear in total hip arthroplasty.

[1]  D L Bartel,et al.  The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants. , 1985, Journal of biomechanical engineering.

[2]  M Semlitsch,et al.  New prospects for a prolonged functional life-span of artificial hip joints by using the material combination polyethylene/aluminium oxide ceramin/metal. , 1977, Journal of biomedical materials research.

[3]  T. Brown,et al.  A sliding-distance-coupled finite element formulation for polyethylene wear in total hip arthroplasty. , 1996, Journal of biomechanics.

[4]  M. Semlitsch,et al.  Reactions of the articular capsule to wear products of artificial joint prostheses. , 1977, Journal of biomedical materials research.

[5]  Thomas D. Brown,et al.  Adaptiive finite element modeling of long‐term polyethylene wear in total hip arthroplasty , 1996 .

[6]  Kurt M. Marshek,et al.  Discretization Pressure-Wear Theory for Bodies in Sliding Contact , 1989 .

[7]  J. Galante,et al.  Contact pressure dependence of wear rates of ultra high molecular weight polyethylene. , 1979, Journal of biomedical materials research.

[8]  R. Brand,et al.  Comparison of hip force calculations and measurements in the same patient. , 1994, The Journal of arthroplasty.

[9]  Duncan Dowson,et al.  Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints: II: A microscopical study of the surfaces of Charnley polyethylene acetabular sockets , 1985 .

[10]  P. D. Wilson,et al.  Acetabular cup wear in total hip arthroplasty. , 1988, The Orthopedic clinics of North America.