Time-of-Flight Magnetic Resonance Angiography With Sparse Undersampling and Iterative Reconstruction: Comparison With Conventional Parallel Imaging for Accelerated Imaging

ObjectivesThe aim of this study was to evaluate the clinical feasibility of accelerated time-of-flight (TOF) magnetic resonance angiography with sparse undersampling and iterative reconstruction (sparse TOF). Materials and MethodsThe local institutional review board approved the study protocols. Twenty healthy volunteers were recruited (mean age, 31.2 years; age range, 22-52 years; 14 men, 6 women). Both sparse TOF and parallel imaging (PI) TOF were obtained on a 3 T scanner. Acceleration factors were 3, 4, 5, 6, and 8 for sparse TOF (Sp 3×, Sp 4×, Sp 5×, Sp 6×, and Sp 8×, respectively) and 2, 3, 4, and 6 for PI TOF (PI 2×, PI 3×, PI 4×, and PI 6×, respectively). Images were reconstructed on the scanner, and maximum intensity projection images were subjected to visual evaluation, wherein each segment of the major brain arteries was independently evaluated by 2 radiologists on a 4-point scale (1, poor; 2, limited; 3, moderate/good quality for diagnosis; and 4, excellent). As a quantitative evaluation, the apparent contrast-to-background deviation (apparent CBD) was calculated at the level of the basilar artery and the pons. ResultsA total number of 1800 segments were subjectively evaluated. There was substantial agreement regarding vessel visualization (&kgr; = 0.759). Sparse TOF received scores above 3 (good for diagnosis) at any acceleration factor up to the third segments of major arteries. The middle and distal segments of PI 4× and PI 6× were graded below 3 (limited or poor diagnostic value). Sp 3×, 4×, 5×, and 6× retained diagnostic information (graded above 3), even at distal segments. The apparent CBD of sparse TOF at any acceleration factor was equivalent to that of PI 2×, whereas the apparent CBD of PI 3×, PI 4×, and PI 6× attenuated with the acceleration factor. ConclusionsSparse TOF can achieve better image quality relative to PI TOF at higher acceleration factors. The diagnostic quality of distal branches (A2/3, M4, P4) was maintained with Sp 6×, which achieved a shorter acquisition time less than half of PI 2×.

[1]  Elmar Eisemann,et al.  User-guided compressed sensing for magnetic resonance angiography , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[2]  M-H Li,et al.  Contrast-free MRA at 3.0 T for the detection of intracranial aneurysms , 2011, Neurology.

[3]  Sairam Geethanath,et al.  Application of Region of Interest Compressed Sensing to accelerate magnetic resonance angiography , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  Michaela Schmidt,et al.  Highly undersampled contrast‐enhanced MRA with iterative reconstruction: Integration in a clinical setting , 2015, Magnetic resonance in medicine.

[5]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[6]  D Chien,et al.  Evaluation of cerebral aneurysms with high-resolution MR angiography using a section-interpolation technique: correlation with digital subtraction angiography. , 1999, AJNR. American journal of neuroradiology.

[7]  J Velikina,et al.  Highly constrained backprojection for time‐resolved MRI , 2006, Magnetic resonance in medicine.

[8]  Christine Preibisch,et al.  Comparison of parallel acquisition techniques generalized autocalibrating partially parallel acquisitions (GRAPPA) and modified sensitivity encoding (mSENSE) in functional MRI (fMRI) at 3T , 2008, Journal of magnetic resonance imaging : JMRI.

[9]  P. M. Parizel,et al.  3D time-of-flight MR angiography of the intracranial vessels: optimization of the technique with water excitation, parallel acquisition, eight-channel phased-array head coil and low-dose contrast administration , 2004, European Radiology.

[10]  H H Quick,et al.  Evaluation of Intracranial Aneurysms with 7 T versus 1.5 T Time-of-Flight MR Angiography – Initial Experience , 2009, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[11]  A. Dunning,et al.  Intraplaque High-Intensity Signal on 3D Time-of-Flight MR Angiography Is Strongly Associated with Symptomatic Carotid Artery Stenosis , 2014, American Journal of Neuroradiology.

[12]  Mehmet Akçakaya,et al.  Accelerated free breathing ECG triggered contrast enhanced pulmonary vein magnetic resonance angiography using compressed sensing , 2014, Journal of Cardiovascular Magnetic Resonance.

[13]  E. Candès,et al.  Stable signal recovery from incomplete and inaccurate measurements , 2005, math/0503066.

[14]  Peter Reimer,et al.  Nephrogenic systemic fibrosis and gadolinium-based contrast media: updated ESUR Contrast Medium Safety Committee guidelines , 2013, European Radiology.

[15]  W Eicher,et al.  MR Angiographic Follow-Up of Intracranial Aneurysms Treated with Detachable Coils: Evaluation of a Blood-Pool Contrast Medium , 2009, American Journal of Neuroradiology.

[16]  Gong Yong Jin,et al.  High resolution MR imaging in patients with symptomatic middle cerebral artery stenosis. , 2012, European journal of radiology.

[17]  Shunji Mugikura,et al.  Intracranial Arterial System: The Main Trunks and Major Arteries of the Cerebrum , 2011 .

[18]  S. Frick,et al.  Compressed Sensing , 2014, Computer Vision, A Reference Guide.

[19]  Guobin Li,et al.  Improving the robustness of 3D turbo spin echo imaging to involuntary motion , 2015, Magnetic Resonance Materials in Physics, Biology and Medicine.

[20]  Walter F Block,et al.  Time‐resolved contrast‐enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory , 2002, Magnetic resonance in medicine.

[21]  G. Schuierer,et al.  Intracranial vascular stenosis and occlusion: comparison of 3D time-of-flight and 3D phase-contrast MR angiography , 1998, Neuroradiology.

[22]  Joachim Hornegger,et al.  Highly undersampled peripheral Time-of-Flight magnetic resonance angiography: optimized data acquisition and iterative image reconstruction , 2015, Magnetic Resonance Materials in Physics, Biology and Medicine.

[23]  P. Boesiger,et al.  Contrast‐enhanced 3D MRA using SENSE , 2000, Journal of magnetic resonance imaging : JMRI.

[24]  Feng Liu,et al.  GPU accelerated high-dimensional compressed sensing MRI , 2014, 2014 13th International Conference on Control Automation Robotics & Vision (ICARCV).

[25]  Peter Schmitt,et al.  3528 Time-Of-Flight with Sparse undersampling ( TOFu ) : towards practical MR applications of the Compressed Sensing , 2013 .

[26]  D. Donoho,et al.  Sparse MRI: The application of compressed sensing for rapid MR imaging , 2007, Magnetic resonance in medicine.

[27]  Marc Teboulle,et al.  A Fast Iterative Shrinkage-Thresholding Algorithm for Linear Inverse Problems , 2009, SIAM J. Imaging Sci..

[28]  Stefan Maderwald,et al.  Comparison of volume, four- and eight-channel head coils using standard and parallel imaging , 2005, European Radiology.

[29]  Mehmet Akçakaya,et al.  Accelerated late gadolinium enhancement cardiac MR imaging with isotropic spatial resolution using compressed sensing: initial experience. , 2012, Radiology.

[30]  Li Feng,et al.  Free-Breathing Contrast-Enhanced Multiphase MRI of the Liver Using a Combination of Compressed Sensing, Parallel Imaging, and Golden-Angle Radial Sampling , 2013, Investigative radiology.

[31]  C. Beaulieu,et al.  Comparison of generalized autocalibrating partially parallel acquisitions and modified sensitivity encoding for diffusion tensor imaging. , 2007, AJNR. American journal of neuroradiology.

[32]  P. Boesiger,et al.  Specific coil design for SENSE: A six‐element cardiac array , 2001, Magnetic resonance in medicine.

[33]  W. Manning,et al.  Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays , 1997, Magnetic resonance in medicine.

[34]  Husheng Li,et al.  Compressed sensing and Cholesky decomposition on FPGAs and GPUs , 2012, Parallel Comput..

[35]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[36]  N Fujita,et al.  MR imaging of middle cerebral artery stenosis and occlusion: value of MR angiography. , 1994, AJNR. American journal of neuroradiology.

[37]  M. Lustig,et al.  Improved pediatric MR imaging with compressed sensing. , 2010, Radiology.

[38]  Thomas E. Yankeelov,et al.  Real-Time Compressive Sensing MRI Reconstruction Using GPU Computing and Split Bregman Methods , 2012, Int. J. Biomed. Imaging.

[39]  Christophe Portefaix,et al.  Follow-up of coiled intracranial aneurysms: comparison of 3D time-of-flight and contrast-enhanced magnetic resonance angiography at 3T in a large, prospective series , 2012, European Radiology.

[40]  M. Nittka,et al.  Partially parallel imaging with localized sensitivities (PILS) , 2000, Magnetic resonance in medicine.

[41]  R. Gonzalez,et al.  Contrast-Enhanced MR Angiography Is Not More Accurate Than Unenhanced 2D Time-of-Flight MR Angiography for Determining ≥70% Internal Carotid Artery Stenosis , 2009, American Journal of Neuroradiology.

[42]  P. Leboit,et al.  Scleromyxoedema-like cutaneous diseases in renal-dialysis patients , 2000, The Lancet.

[43]  Sung Hun Kim,et al.  The effectiveness of 3T time-of-flight magnetic resonance angiography for follow-up evaluations after the stent-assisted coil embolization of cerebral aneurysms , 2014, Acta radiologica.

[44]  J S Lewin,et al.  High Resolution, Magnetization Transfer Saturation, Variable Flip Angle, Time‐of‐Flight MRA in the Detection of Intracranial Vascular Stenoses , 1995, Journal of computer assisted tomography.

[45]  Michael Lustig,et al.  Clinical performance of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced pediatric abdominal MR angiography , 2015, Pediatric Radiology.

[46]  Edgar Mueller,et al.  Dynamic cardiac MRI reconstruction with weighted redundant Haar wavelets , 2022 .

[47]  T. Grobner Gadolinium--a specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis? , 2006, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.