Investigation of solid particle number measurement: existence and nature of sub 23 nm particles under PMP methodology

Abstract A Particle Measurement Program (PMP) compliant system, an AVL advanced particle counter (APC) and an alternative volatile particle removal system, a catalytic stripper (CS) were evaluated and compared for measuring solid particle number (PN) emissions. The evaluations and comparisons were conducted using sulfuric acid and hydrocarbon particles as model volatile particles in laboratory tests, and diluted exhaust from a diesel particle filter (DPF)-equipped heavy-duty diesel vehicle operated on a heavy-duty chassis dynamometer under steady speed conditions at two different engine loads. For the laboratory test, both the APC and CS removed more than 99% of the volatile particles in terms of PN when using aerosols composed of pure sulfuric acid or hydrocarbons. When using laboratory test aerosols consisting of mixtures of sulfuric acid and hydrocarbons more than 99% of the particles were removed by the APC but the surviving particles were no longer entirely volatile, 12–14% were solid. For the chassis dynamometer test, PN emissions between 3 and 10 nm downstream the APC were ∼2 and 7 times higher than the PN emissions of particles above 10 nm at the 74% and 26% engine load, respectively. At the 26% engine load, PN level of the 3–10 nm particles downstream the APC were significantly higher than that in the dilution tunnel, demonstrating that the APC was making 3–10 nm particles. The PN emission of 3–10 nm particles downstream the APC was related to the heating temperature of the APC evaporation tube, suggesting these particles are artifacts formed by renucleation of semivolatiles. Considerably fewer particles between 3 to 10 nm were seen downstream of the CS for both engine loads due mainly to removal of semivolatile material by the catalytic substrates, although some of this difference could be attributed to diffusion and thermophoretic losses. The findings of this study imply that improvement of the current PMP protocol would be necessary if the PMP were to be used in other applications where the PN emissions of particles below 23 nm are important.

[1]  D. Kittelson,et al.  Evaluation of thermal denuder and catalytic stripper methods for solid particle measurements , 2010 .

[2]  H. Burtscher Physical characterization of particulate emissions from diesel engines: a review , 2005 .

[3]  Alexander Bergmann,et al.  Calibration and accuracy of a particle number measurement system , 2010 .

[4]  Martin Mohr,et al.  Separation of volatile and non-volatile aerosol fractions by thermodesorption: instrumental development and applications , 2001 .

[5]  David B. Kittelson,et al.  On-road and laboratory evaluation of combustion aerosols-Part1: Summary of diesel engine results , 2006 .

[6]  Jacob Swanson,et al.  Alternatives to the Gravimetric Method for Quantification of Diesel Particulate Matter near the Lower Level of Detection , 2010, Journal of the Air & Waste Management Association.

[7]  Jan Czerwinski,et al.  Research on Particle Emissions of Modern 2-Stroke Scooters , 2006 .

[8]  Jon Andersson,et al.  Heavy Duty Particle Measurement Programme (PMP): Exploratory Work for the Definition of the Test Protocol , 2009 .

[9]  J Wayne Miller,et al.  Development and application of a mobile laboratory for measuring emissions from diesel engines. 1. Regulated gaseous emissions. , 2004, Environmental science & technology.

[10]  D. Kittelson,et al.  Effect of organometallic fuel additives on nanoparticle emissions from a gasoline passenger car. , 2010, Environmental science & technology.

[11]  L. Pirjola,et al.  First gaseous sulfuric acid measurements in automobile exhaust: Implications for volatile nanoparticle formation , 2006 .

[12]  G. Martini,et al.  Future European emission standards for vehicles: the importance of the UN-ECE Particle Measurement Programme , 2009, Biomarkers : biochemical indicators of exposure, response, and susceptibility to chemicals.

[13]  Alberto Ayala,et al.  Investigation of Ultrafine Particle Number Measurements from a Clean Diesel Truck Using the European PMP Protocol , 2007 .

[14]  Alberto Ayala,et al.  Evaluation of the European PMP Methodologies during On-Road and Chassis Dynamometer Testing for DPF Equipped Heavy-Duty Diesel Vehicles , 2009 .

[15]  Topi Rönkkö,et al.  Dependence between nonvolatile nucleation mode particle and soot number concentrations in an EGR equipped heavy-duty Diesel engine exhaust. , 2010, Environmental science & technology.

[16]  Kent C Johnson,et al.  Development and application of a mobile laboratory for measuring emissions from diesel engines. 2. Sampling for toxics and particulate matter. , 2004, Environmental science & technology.

[17]  R. Scott,et al.  The Action of 96% Sulfuric Acid on Alkanes at 60°1 , 1954 .

[18]  J. Schauer,et al.  Chemical speciation of PM emissions from heavy-duty diesel vehicles equipped with diesel particulate filter (DPF) and selective catalytic reduction (SCR) retrofits , 2009 .

[19]  Timothy V. Johnson,et al.  Review of diesel emissions and control , 2009 .

[20]  Liisa Pirjola,et al.  Heavy duty diesel engine exhaust aerosol particle and ion measurements. , 2009, Environmental science & technology.

[21]  A. De Filippo,et al.  Diesel nucleation mode particles: semivolatile or solid? , 2008, Environmental science & technology.

[22]  G. Martini,et al.  Evaluation of the particle measurement programme (PMP) protocol to remove the vehicles' exhaust aerosol volatile phase. , 2010, The Science of the total environment.

[23]  P. Mcmurry,et al.  A closure study of aerosol mass concentration measurements: Comparison of values obtained with filters and by direct measurements of mass distributions , 2003 .

[24]  David B. Kittelson,et al.  Influence of a catalytic stripper on the response of real time aerosol instruments to diesel exhaust aerosol , 2005 .

[25]  B. Cooper,et al.  Role of NO in Diesel Particulate Emission Control , 1989 .

[26]  Alberto Ayala,et al.  Effect of advanced aftertreatment for PM and NOx reduction on heavy-duty diesel engine ultrafine particle emissions. , 2011, Environmental science & technology.

[27]  D. Kittelson,et al.  Real time measurement of volatile and solid exhaust particles using a catalytic stripper , 1995 .

[28]  Liisa Pirjola,et al.  Nucleation mode particles with a nonvolatile core in the exhaust of a heavy duty diesel vehicle. , 2007, Environmental science & technology.

[29]  Barouch Giechaskiel,et al.  Theoretical Investigation of Volatile Removal Efficiency of Particle Number Measurement Systems , 2010 .