Changes in measured intraocular pressure after hyperopic photorefractive keratectomy

Purpose: To investigate the effect of hyperopic photorefractive keratectomy (PRK) on intraocular pressure (IOP) measurements. Setting: University of Ottawa Eye Institute, Ottawa Hospital, Ottawa, Canada. Methods: In this retrospective cohort study, IOP and central corneal thickness (CCT) were measured preoperatively and at 1, 2, 3, 6, 12, 18, and 24 months in 191 eyes that had hyperopic PRK with the VISX Star excimer laser. All corrections applied were between +1.00 and +6.50 diopters (D) of sphere and less than 3.75 D of cylinder. Results: At all postoperative examinations, the mean IOP in the hyperopic PRK group was 1.0 to 1.8 mm Hg lower than the preoperative IOP (P < .001). A large range of IOP changes was found across the population; eg, at 6 months, 49% of the eyes had a change in IOP from baseline of at least ±3 mm Hg. A mean reduction of 19 &mgr;m of CCT was found with pachymetry after surgery (P < .001). The change in IOP readings postoperatively was not correlated with age, sex, keratometric readings, or applied correction. Changes in IOP were strongly correlated with preoperative IOP at all time points and with preoperative CCT at 18 and 24 months (P < .001). After hyperopic PRK, the measured IOP was more likely to increase in patients with preoperative IOPs less than 14.5 mm Hg and more likely to decrease in patients with preoperative IOPs above 14.5 mm Hg. Conclusion: Changes in IOP after hyperopic PRK were similar to changes after myopic PRK, despite only minimal changes in the CCT. This suggests that hyperopic PRK results in biomechanical effects that modify the elastic properties of the cornea beyond the changes in rigidity expected from central corneal thinning. There was a strong negative correlation between the measured preoperative IOP and the change in IOP postoperatively that was likely the result of regression of the mean effect.

[1]  D. Minckler,et al.  Clinical evaluation of the Oculab Tono-Pen. , 1987, American journal of ophthalmology.

[2]  I. Schipper,et al.  Central and peripheral pressure measurements with the Goldmann tonometer and Tono‐Pen after photorefractive keratectomy for myopia , 2000, Journal of cataract and refractive surgery.

[3]  P. Lichter,et al.  Clinical comparison of the Oculab Tono-Pen to the Goldmann applanation tonometer. , 1987, Ophthalmology.

[4]  K. Damji,et al.  Positive correlation between Tono-Pen intraocular pressure and central corneal thickness. , 1998, Ophthalmology.

[5]  D. Shin,et al.  Comparison of the Tono-Pen to the Goldmann applanation tonometer. , 1988, Archives of ophthalmology.

[6]  J. Grégoire,et al.  Accuracy of Goldmann tonometry after refractive surgery , 1997, Journal of cataract and refractive surgery.

[7]  T. Tervo,et al.  Effect of photorefractive keratectomy on the accuracy of pneumatonometer readings in rabbits. , 1996, Investigative ophthalmology & visual science.

[8]  H. D. Cavanagh,et al.  Reliability of intraocular pressure measurements after myopic excimer photorefractive keratectomy. , 1998, Ophthalmology.

[9]  A. Hofman,et al.  Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam Study. , 1997, American journal of ophthalmology.

[10]  W. Hodge,et al.  Laser vision correction for low hyperopia. An 18-month assessment of safety and efficacy. , 1998, Ophthalmology.

[11]  W. Hodge,et al.  Correction of intraocular pressure for changes in central corneal thickness following photorefractive keratectomy. , 1998, Canadian journal of ophthalmology. Journal canadien d'ophtalmologie.

[12]  R. Rössler,et al.  Comparison of intraocular pressure measurements with the Oculab Tono-Pen vs manometry in humans shortly after death. , 1988 .

[13]  C. Roberts The cornea is not a piece of plastic. , 2000, Journal of refractive surgery.

[14]  R. Stein,et al.  The effect of corneal thickness on applanation tonometry. , 1993, American journal of ophthalmology.

[15]  C. Gabrieli,et al.  Excimer laser photorefractive keratectomy for hyperopia. , 2001, Ophthalmic surgery and lasers.

[16]  S. Shah,et al.  Reduction in intraocular pressure after excimer laser photorefractive keratectomy. Correlation with pretreatment myopia. , 1997, Ophthalmology.

[17]  D. Zadok,et al.  Tono-Pen versus Goldmann tonometry after excimer laser photorefractive keratectomy. , 1999, Journal of cataract and refractive surgery.

[18]  M. Raizman,et al.  One-year results of excimer laser photorefractive keratectomy for low to moderate myopia. , 1994, Archives of ophthalmology.

[19]  N. Ehlers,et al.  APPLANATION TONOMETRY AND CENTRAL CORNEAL THICKNESS , 1975, Acta ophthalmologica.

[20]  T Seiler,et al.  Excimer laser photorefractive keratectomy. , 1995, Survey of ophthalmology.

[21]  P. D. Oldham,et al.  A note on the analysis of repeated measurements of the same subjects. , 1962, Journal of chronic diseases.

[22]  W. A. Boothe,et al.  The Tono-Pen. A manometric and clinical study. , 1988, Archives of ophthalmology.

[23]  H. H. Mark,et al.  Corneal curvature in applanation tonometry. , 1973, American journal of ophthalmology.

[24]  M. Whitacre,et al.  The effect of excimer laser photorefractive keratectomy on intraocular pressure measurements using the Goldmann applanation tonometer. , 1997, Ophthalmology.

[25]  I. Schipper,et al.  Intraocular pressure after excimer laser photorefractive keratectomy for myopia. , 1995, Journal of refractive surgery.

[26]  J. Holladay,et al.  Goldmann applanation tonometry in patients with regular corneal astigmatism. , 1983, American journal of ophthalmology.

[27]  T. Colton,et al.  The distribution of intraocular pressures in the general population. , 1980, Survey of ophthalmology.