Drift correction for single-molecule imaging by molecular constraint field, a distance minimum metric

BackgroundThe recent developments of far-field optical microscopy (single molecule imaging techniques) have overcome the diffraction barrier of light and improve image resolution by a factor of ten compared with conventional light microscopy. These techniques utilize the stochastic switching of probe molecules to overcome the diffraction limit and determine the precise localizations of molecules, which often requires a long image acquisition time. However, long acquisition times increase the risk of sample drift. In the case of high resolution microscopy, sample drift would decrease the image resolution.ResultsIn this paper, we propose a novel metric based on the distance between molecules to solve the drift correction. The proposed metric directly uses the position information of molecules to estimate the frame drift. We also designed an algorithm to implement the metric for the general application of drift correction. There are two advantages of our method: First, because our method does not require space binning of positions of molecules but directly operates on the positions, it is more natural for single molecule imaging techniques. Second, our method can estimate drift with a small number of positions in each temporal bin, which may extend its potential application.ConclusionsThe effectiveness of our method has been demonstrated by both simulated data and experiments on single molecular images.

[1]  Mark Bates,et al.  Super-resolution microscopy by nanoscale localization of photo-switchable fluorescent probes. , 2008, Current opinion in chemical biology.

[2]  Mark Bates,et al.  Evaluation of fluorophores for optimal performance in localization-based super-resolution imaging , 2011, Nature Methods.

[3]  S. Hess,et al.  Precisely and accurately localizing single emitters in fluorescence microscopy , 2014, Nature Methods.

[4]  E. Parzen On Estimation of a Probability Density Function and Mode , 1962 .

[5]  Michael D. Mason,et al.  Ultra-high resolution imaging by fluorescence photoactivation localization microscopy. , 2006, Biophysical journal.

[6]  U. Endesfelder,et al.  A hydrophilic gel matrix for single-molecule super-resolution microscopy , 2013, Optical Nanoscopy.

[7]  S. Hell Far-Field Optical Nanoscopy , 2007, Science.

[8]  S. Hess,et al.  Imaging biological structures with fluorescence photoactivation localization microscopy , 2009, Nature Protocols.

[9]  Axel Munk,et al.  Drift estimation for single marker switching based imaging schemes. , 2012, Optics express.

[10]  Sjoerd Stallinga,et al.  Measuring image resolution in optical nanoscopy , 2013, Nature Methods.

[11]  Yongdeng Zhang,et al.  Rational design of true monomeric and bright photoactivatable fluorescent proteins , 2012, Nature Methods.

[12]  J. Lippincott-Schwartz,et al.  Imaging Intracellular Fluorescent Proteins at Nanometer Resolution , 2006, Science.

[13]  Michael J Rust,et al.  Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM) , 2006, Nature Methods.

[14]  W. Webb,et al.  Precise nanometer localization analysis for individual fluorescent probes. , 2002, Biophysical journal.

[15]  Christian Eggeling,et al.  Fluorescence Nanoscopy in Whole Cells by Asynchronous Localization of Photoswitching Emitters , 2007, Biophysical journal.

[16]  M. Rosenblatt Remarks on Some Nonparametric Estimates of a Density Function , 1956 .

[17]  Steven P. Callahan,et al.  Sample drift correction in 3D fluorescence photoactivation localization microscopy , 2011 .