Current trends in total hip arthroplasty.

After 20 years of application, with excellent short-term and long-term results, uncemented total hip arthroplasty (THA) is now generally regarded as the standard procedure for younger patients undergoing THA. However, expectations regarding hip replacement are continuously rising, along with the increasing number of young and active patients undergoing hip arthroplasty: a complication rate, including postoperative dislocation, close to zero, faster postoperative rehabilitation, low wear even in active patients, high durability and long term survival, etc. Demographic changes in aging societies are also leading to an increased need for cost-effective THA for the low-demand trauma patient. For high-demand patients, modern THA bearings, such as ceramic-ceramic articulations and other improved PE and metal materials, provide high durability and low wear, if the components are properly aligned. Navigation technology has been introduced in THA to ensure perfect component positioning without outliers and concomitant risk of increased wear and implant failure. Minimally and less invasive approaches are becoming increasingly popular in order to facilitate rehabilitation and fast-track surgery in younger patients. Navigation provides assistance for implant positioning in procedures with limited surgical exposure and visibility. New bone-preserving implants, such as surface replacement or short-stemmed femoral shaft prostheses, have been introduced especially for younger patients. Some of these new procedures are still under development,and the long-term results of new implant concepts have to be evaluated over the next decades. Not every modern concept will likely stand the test of time, but some will be beneficial for patients undergoing total hip arthroplasty in the future.

[1]  Michael H Huo,et al.  Total Hip Arthroplasty Through a Minimally Invasive Anterior Surgical Approach , 2003, The Journal of bone and joint surgery. American volume.

[2]  B. Morrey,et al.  A conservative femoral replacement for total hip arthroplasty. A prospective study. , 2000, The Journal of bone and joint surgery. British volume.

[3]  T. Light,et al.  Anterior approach to hip arthroplasty. , 1980, Clinical orthopaedics and related research.

[4]  D. Back,et al.  Femoral neck fractures following Birmingham hip resurfacing: a national review of 50 cases. , 2005, The Journal of bone and joint surgery. British volume.

[5]  D. Wohlrab,et al.  [Advantages of minimal invasive total hip replacement in the early phase of rehabilitation]. , 2004, Zeitschrift fur Orthopadie und ihre Grenzgebiete.

[6]  Richard L Wixson,et al.  Computer assisted navigation in total knee arthroplasty: improved coronal alignment. , 2005, The Journal of arthroplasty.

[7]  J. Jerosch,et al.  Antero-lateral minimal invasive (ALMI) approach for total hip arthroplasty technique and early results , 2006, Archives of Orthopaedic and Trauma Surgery.

[8]  P. Pynsent,et al.  Metal on Metal Surface Replacement of the Hip: Experience of the McMinn Prosthesis , 1996, Clinical orthopaedics and related research.

[9]  A. Peters,et al.  Künstlicher Hüftgelenksersatz über eine posteriore Mini-Inzision - Ergebnisse in 76 aufeinander folgenden Fällen , 2005 .

[10]  M. Huo,et al.  Anterior approach to total hip replacement: surgical technique and clinical results of our first one thousand cases using non-cemented prostheses. , 1993, The Yale journal of biology and medicine.

[11]  Steffen Kohler,et al.  Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventionally implanted prostheses. , 2005, The Journal of arthroplasty.

[12]  T. Ilchmann,et al.  Subsidence Pattern of a Cementless Straight Titanium Alloy Femoral Stem - A Radiographic Study with EBRA-FCA , 2005 .

[13]  J. Nixon,et al.  A ten-to-15 year follow-up of the Cementless Spotorno stem. , 2003, The Journal of bone and joint surgery. British volume.

[14]  A Shimmin,et al.  Early results of primary Birmingham hip resurfacings. An independent prospective study of the first 230 hips. , 2005, The Journal of bone and joint surgery. British volume.

[15]  K. Weise,et al.  Long-term results of an uncemented straight femoral shaft prosthesis. , 2006, Hip international : the journal of clinical and experimental research on hip pathology and therapy.

[16]  M. Nogler,et al.  Direct, Anterior, Single-Incision Approach , 2004 .

[17]  D. Vandevelde,et al.  Reduction in Variability of Acetabular Cup Abduction Using Computer Assisted Surgery: A Prospective and Randomized Study , 2002, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[18]  K. Oinuma,et al.  Total hip arthroplasty by a minimally invasive, direct anterior approach. , 2007, Operative Orthopadie und Traumatologie.

[19]  D. Mcminn,et al.  History and modern concepts in surface replacement , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[20]  Christian Heisel,et al.  Bearing surface options for total hip replacement in young patients. , 2003, Instructional course lectures.

[21]  K. Weise,et al.  Results of an uncemented straight femoral shaft prosthesis after 9 years of follow-up. , 2000, The Journal of arthroplasty.

[22]  Hartmuth Kiefer,et al.  OrthoPilot total hip arthroplasty workflow and surgery. , 2005, Orthopedics.

[23]  Michael Nogler,et al.  Navigated minimal invasive total hip arthroplasty. , 2004, Surgical technology international.

[24]  M Honl,et al.  [Comparison of total hip replacements cup orientation and position. Navigation vs. conventional manual implantation of hip prostheses]. , 2005, Der Orthopade.

[25]  Laurent Sedel,et al.  Fractures of Ceramic Bearings: History and Present Status , 2003, Clinical orthopaedics and related research.

[26]  Seung-Jae Lim,et al.  Ceramic failure after total hip arthroplasty with an alumina-on-alumina bearing. , 2006, The Journal of bone and joint surgery. American volume.

[27]  M. Rittmeister,et al.  [A posterior mini-incision for total hip arthroplasty -- results of 76 consecutive cases]. , 2005, Zeitschrift fur Orthopadie und ihre Grenzgebiete.

[28]  B F Morrey,et al.  Short-stemmed uncemented femoral component for primary hip arthroplasty. , 1989, Clinical orthopaedics and related research.