A new cone-beam computed tomography system for dental applications with innovative 3D software

AbstractObjective Cone beam computed tomography (CBCT) is an important image technique for oral surgery (dentoalveolar surgery and dental implantology) and maxillofacial applications. This technique requires compact sized scanners with a relatively low radiation dosage, which makes them suitable for imaging of the craniofacial region. This article aims to present the concept and the preliminary findings obtained with the prototype of a new CBCT scanner with dedicated 3D software, specifically designed for dental imaging. Methods The prototype implements an X-ray tube with a nominal focal spot of 0.5 mm operating at 70–100 kVp and 1–4 mA. The detector is a 6 in. image intensifier coupled with a digital CCD camera. Dosimetry was performed on a RANDO anthropomorphic phantom using Beryllium Oxide thermo-luminescent dosimeters positioned in the phantom in the following site: eyes, thyroid, skin (lips, cheeks, back of the neck), brain, mandible, maxilla and parotid glands. Doses were measured using four configurations, changing the field-of-view (4′′ and 6′′) and acquisition time (10 and 20 s) of the CBCT. Acquisitions were performed with different parameters regarding the x-ray tube, pixel size and acquisition geometries to evaluate image quality in relation to modulation transfer function (MTF), noise and geometric accuracy. Results The prototype was able to acquire a complete maxillofacial scan in 10–15 s. The CT reconstruction algorithm delivered images that were judged to have high quality, allowing for precise volume rendering. The radiation dose was determined to be 1–1.5 times that of the dose applied during conventional dental panoramic studies. Conclusion Preliminary studies using the CBCT prototype indicate that this device provides images with acceptable diagnostic content at a relatively low radiation dosage, if compared to systems currently available on the market.

[1]  S. Brooks,et al.  Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT. , 2006, Dento maxillo facial radiology.

[2]  A. Farman,et al.  Clinical applications of cone-beam computed tomography in dental practice. , 2006, Journal.

[3]  H G Gröndahl,et al.  Absorbed doses from computed tomography for dental implant surgery: comparison with conventional tomography. , 1993, Dento maxillo facial radiology.

[4]  Allan G Farman,et al.  ALARA still applies. , 2005, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[5]  P Sukovic,et al.  Cone beam computed tomography in craniofacial imaging. , 2003, Orthodontics & craniofacial research.

[6]  T. Hosoi,et al.  Comparison of patient dose from imaging protocols for dental implant planning using conventional radiography and computed tomography. , 2001, Dento maxillo facial radiology.

[7]  J. Boone,et al.  An analytical edge spread function model for computer fitting and subsequent calculation of the LSF and MTF. , 1994, Medical physics.

[8]  Yoshinori Arai,et al.  A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine. , 2003, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[9]  C. Lascala,et al.  Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom). , 2004, Dento maxillo facial radiology.

[10]  J Brief,et al.  Clinical indications for digital volume tomography in oral and maxillofacial surgery. , 2002, Dento maxillo facial radiology.

[11]  P. Mozzo,et al.  A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results , 1998, European Radiology.

[12]  E. Vañó,et al.  Reference doses in dental radiodiagnostic facilities. , 2001, The British journal of radiology.

[13]  M. Cohnen,et al.  Radiation dose in dental radiology , 2002, European Radiology.

[14]  K Araki,et al.  Characteristics of a newly developed dentomaxillofacial X-ray cone beam CT scanner (CB MercuRay): system configuration and physical properties. , 2004, Dento maxillo facial radiology.

[15]  Haijo Jung,et al.  Quantitative evaluation of acquisition parameters in three-dimensional imaging with multidetector computed tomography using human skull phantom. , 2002, Journal of digital imaging.

[16]  D. Hatcher,et al.  Radiation absorbed in maxillofacial imaging with a new dental computed tomography device. , 2003, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.