Analysis of the possibility of analog detectors calibration by exploiting stimulated parametric down conversion.

Spontaneous parametric down conversion (SPDC) has been largely exploited as a tool for absolute calibration of photon-counting detectors, i.e detectors registering very small photon fluxes. In [J. Opt. Soc. Am. B 23, 2185 (2006)] we derived a method for absolute calibration of analog detectors using SPDC emission at higher photon fluxes, where the beam is seen as a continuum by the detector. Nevertheless intrinsic limitations appear when high-gain regime of SPDC is required to reach even larger photon fluxes. Here we show that stimulated parametric down conversion allow one to avoid this limitation, since stimulated photon fluxes are increased by the presence of the seed beam.

[1]  A. Penin,et al.  Possibility of absolute calibration of analog detectors by using parametric downconversion: a systematic study , 2005, quant-ph/0511093.

[2]  M. Genovese Research on hidden variable theories: A review of recent progresses , 2005, quant-ph/0701071.

[3]  M. Chekhova,et al.  Single-photon detector calibration by means of conditional polarization rotation , 2005 .

[4]  M. Chekhova,et al.  Absolute quantum efficiency measurements by means of conditioned polarization rotation , 2004, IEEE Transactions on Instrumentation and Measurement.

[5]  M. Chekhova,et al.  Conditional unitary transformation on biphotons , 2003, quant-ph/0312211.

[6]  H. Bechmann-Pasquinucci,et al.  Quantum cryptography , 2001, quant-ph/0101098.

[7]  G. Brida,et al.  An application of two-photon entangled states to quantum metrology , 1999, quant-ph/9911032.

[8]  D. Klyshko,et al.  Photon noise: observation, squeezing, interpretation , 1995 .

[9]  V. M. Ginzburg,et al.  Absolute meter of photodetector quantum efficiency based on the parametric down-conversion effect , 1993 .

[10]  D. Klyshko,et al.  The prospects of quantum photometry , 1987 .

[11]  D. Klyshko,et al.  Use of two-photon light for absolute calibration of photoelectric detectors , 1980 .

[12]  I. Nishio,et al.  Analysis of noises in photocurrent time‐correlation spectroscopy of scattered light , 1976 .

[13]  David C. Burnham,et al.  Observation of Simultaneity in Parametric Production of Optical Photon Pairs , 1970 .

[14]  Gilles Brassard,et al.  Quantum Cryptography , 2005, Encyclopedia of Cryptography and Security.

[15]  Alan L. Migdall,et al.  Correlated‐Photon Metrology Without Absolute Standards , 1999 .

[16]  R. Mcintyre Multiplication noise in uniform avalanche diodes , 1966 .