Three-dimensional joint range of motion measurements from skeletal coordinate data.

Frequently, joint range of motion is reported for a single plane (eg., sagittal, coronal, or transverse). However, the arc of joint motion during functional activities and many clinical tests encompasses motion in all three planes simultaneously. The purposes of this paper are to discuss a method to obtain relative joint three-dimensional angular displacement measurements using coordinates from skeletal landmarks and provide an analytical example of the method using three-dimensional angular displacement of the knee joint as a model. In order to calculate the three-dimensional relative motion, an orthogonal reference frame for each bone needs to be established. To establish the local reference frame, three noncollinear points are used to define unit vectors that are mutually perpendicular. Three-dimensional angles can be determined to describe the magnitude of the moving body rotation angles about the X, Y, and Z axes. These angles indicate the relative motion of body segments for abduction/adduction, flexion/extension, and internal/external rotation. The technique provides a more vigorous biomechanical understanding of joint motion and may have implications for measuring patient progress and evaluating joint mobilization treatment. This technique may also serve as a basis for developing new evaluation and treatment techniques.

[1]  J. Balogun,et al.  Inter- and Intratester Reliability of Measuring Neck Motions with Tape Measure and Myrin® Gravity—Reference Goniometer , 1989 .

[2]  J. G. Andrews,et al.  Actions of hip muscles. , 1986, Physical therapy.

[3]  M P Kadaba,et al.  On the estimation of joint kinematics during gait. , 1991, Journal of biomechanics.

[4]  E S Grood,et al.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. , 1983, Journal of biomechanical engineering.

[5]  M S Hefzy,et al.  Error analysis of a system for measuring three-dimensional joint motion. , 1983, Journal of biomechanical engineering.

[6]  B F Morrey,et al.  Three‐dimensional kinematics of glenohumeral elevation , 1991, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[7]  R. Dontigny Anterior dysfunction of the sacroiliac joint as a major factor in the etiology of idiopathic low back pain syndrome. , 1990, Physical therapy.

[8]  C. Hsieh,et al.  Active neck motion measurements with a tape measure*. , 1986, The Journal of orthopaedic and sports physical therapy.

[9]  O. Lindahl,et al.  The "screw-home" movement in the knee-joint. , 1966, Acta orthopaedica Scandinavica.

[10]  H. Reynolds Three-dimensional kinematics in the pelvic girdle. , 1980, The Journal of the American Osteopathic Association.

[11]  G. Smidt,et al.  A quantitative analysis of knee motion during activities of daily living. , 1972, Physical therapy.

[12]  K. Cerny Pathomechanics of stance. Clinical concepts for analysis. , 1984, Physical therapy.

[13]  G. Smidt,et al.  Evaluation of the metrecom and its use in quantifying skeletal landmark locations. , 1992, The Journal of orthopaedic and sports physical therapy.

[14]  Robert P. Hubbard,et al.  Anatomical Frames of Reference and Biomechanics , 1980 .