Analysis of hand forces in health and disease during maximum isometric grasping of cylinders

An analysis of force distribution in the hand during maximum isometric grasping actions is reported in a detailed and accurate manner. A microcomputer-controlled instrument which measures all 12 phalangeal forces of fingers simultaneously, in a single attempt at squeezing a cylindrical object, is described. The study involved 20 normal subjects of different weights and age groups grasping tubes of 50 mm, 75 mm, 90 mm and 110 mm diameters. Normal grasp forces decreased significantly with the increase in tube diameter, with the force being concentrated more on the distal segments of the fingers than on the proximal and middle segments. The mean percentage contributions of finger forces to total grip strength, from index to little fingers, were 31, 33, 22 and 24 per cent, respectively. The study was extended to cover leprotic and paralytic hands to assess their functional capabilities. In the case of leprosy subjects, the grip strength decreased with the severity of the disease and was only about 50 per cent of that of normal subjects. In hemiplegics, the grip strength was only about one-eighth of the normal values. The above assessment procedure provides baseline data which could sere as guidelines to a clinician in assessing the severity of the disease and observing the patient's recovery following the treatment. It would also be useful in the design of hand-operated controls and prosthetic arms.