Numerical evaluation on shell buckling of empty thin-walled steel tanks under wind load according to current American and European design codes

Liquid storage steel tanks are vertical above-ground cylindrical shells and as typical thin-walled structures, they are very sensitive to buckling under wind loads, especially when they are empty or at low liquid level. Previous studies revealed discrepancies in buckling resistance of empty tanks between the design method proposed by the American Standard API 650 and the analytical formulas recommended by the European Standard EN1993-1-6 and EN1993-4-2. This study presents a comparison between the provisions of current design codes by performing all types of numerical buckling analyses recommended by Eurocodes (i.e. LBA-linear elastic bifurcation analysis, GNA-geometrically nonlinear elastic analysis of the perfect tank and GNIA-geometrically nonlinear elastic analysis of the imperfect tank). Such analyses are performed in order to evaluate the buckling resistance of two existing thin-walled steel tanks, with large diameters and variable wall thickness. In addition, a discussion is unfolded about the differences between computational and analytical methods and the conservatism that the latter method imposes. An influence study on the geometric imperfections and the boundary conditions is also conducted. Investigation on the boundary conditions at the foot of the tank highlights the sensitivity to the fixation of the vertical translational degree of freedom. Further, it is indicated that the imperfection magnitude recommended by the EN1993-1-6 is extremely unfavorable when applied to large diameter tanks. Comments and conclusions achieved could be helpful in order to evaluate the safety of the current design codes and shed more light towards the most accurate one.

[1]  Luis A. Godoy,et al.  Buckling estimates for oil storage tanks: Effect of simplified modeling of the roof and wind girder , 2015 .

[2]  Luis A. Godoy,et al.  Performance of Storage Tanks in Oil Facilities Damaged by Hurricanes Katrina and Rita , 2007 .

[3]  Luis A. Godoy,et al.  Wind pressure and buckling of grouped steel tanks , 2007 .

[4]  Luis A. Godoy,et al.  Wind buckling of metal tanks during their construction , 2010 .

[5]  Yang Zhao,et al.  Wind loads on fixed-roof cylindrical tanks with very low aspect ratio , 2014 .

[6]  R. Greiner,et al.  Effect of imperfections on wind-loaded cylindrical shells , 1995 .

[7]  Chris Letchford,et al.  A Comparison of Wind Loads on Circular Bins, Silos and Tanks , 2014 .

[8]  Luis A. Godoy,et al.  Imperfection sensitivity to elastic buckling of wind loaded open cylindrical tanks , 2002 .

[9]  C. R. Hendy,et al.  Designers' Guide to EN 1993-2 Eurocode 3: Design of Steel Structures, Part 2: Steel Bridges , 2007 .

[10]  Luis A. Godoy,et al.  Shielding effects and buckling of steel tanks in tandem arrays under wind pressures , 2005 .

[11]  M. A. Haroun,et al.  Effect of FRP composites on buckling capacity of anchored steel tanks , 2010 .

[12]  Chrysanthos Maraveas,et al.  Shell buckling evaluation of thin-walled steel tanks filled at low liquid level according to current design codes , 2013 .

[13]  Yasushi Uematsu,et al.  Design wind force coefficients for open-topped oil storage tanks focusing on the wind-induced buckling , 2014 .

[14]  Yasushi Uematsu,et al.  Design wind loads for open-topped storage tanks in various arrangements , 2015 .

[15]  Luis A. Godoy,et al.  Challenges in the computation of lower-bound buckling loads for tanks under wind pressures , 2010 .

[16]  Luis A. Godoy,et al.  Wind pressures and buckling of cylindrical steel tanks with a conical roof , 2005 .

[17]  Yasushi Uematsu,et al.  Deflection and buckling behavior of thin, circular cylindrical shells under wind loads , 1985 .

[18]  R Greiner Cylindrical shells: wind loading , 1998 .

[19]  N. J. Cook Designers' Guide to EN 1991-1-4 Eurocode 1: Actions on structures, general actions part 1-4. Wind actions , 2007 .

[20]  Yang Zhao,et al.  Buckling of cylindrical open-topped steel tanks under wind load , 2014 .