Validity and reproducibility of the ErgomoPro power meter compared with the SRM and Powertap power meters.

PURPOSE The ErgomoPro (EP) is a power meter that measures power output (PO) during outdoor and indoor cycling via 2 optoelectronic sensors located in the bottom bracket axis. The aim of this study was to determine the validity and the reproducibility of the EP compared with the SRM crank set and Powertap hub (PT). METHODS The validity of the EP was tested in the laboratory during 8 submaximal incremental tests (PO: 100 to 400 W), eight 30-min submaximal constant-power tests (PO = 180 W), and 8 sprint tests (PO > 750 W) and in the field during 8 training sessions (time: 181 +/- 73 min; PO: approximately 140 to 160 W). The reproducibility was assessed by calculating the coefficient of PO variation (CV) during the submaximal incremental and constant tests. RESULTS The EP provided a significantly higher PO than the SRM and PT during the submaximal incremental test: The mean PO differences were +6.3% +/- 2.5% and +11.1% +/- 2.1% respectively. The difference was greater during field training sessions (+12.0% +/- 5.7% and +16.5% +/- 5.9%) but lower during sprint tests (+1.6% +/- 2.5% and +3.2% +/- 2.7%). The reproducibility of the EP is lower than those of the SRM and PT (CV = 4.1% +/- 1.8%, 1.9% +/- 0.4%, and 2.1% +/- 0.8%, respectively). CONCLUSIONS The EP power meter appears less valid and reliable than the SRM and PT systems.

[1]  R. Candau,et al.  Validity and reliability of the Polar S710 mobile cycling powermeter. , 2003, International journal of sports medicine.

[2]  A. Nevill,et al.  Why the analysis of performance variables recorded on a ratio scale will invariably benefit from a log transformation. , 1997, Journal of sports sciences.

[3]  S Duc,et al.  Validity and Reliability of the PowerTap Mobile Cycling Powermeter when Compared with the SRM Device , 2005, International journal of sports medicine.

[4]  Steve Haake,et al.  The Engineering of Sport , 1998 .

[5]  G Atkinson,et al.  Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports Medicine , 1998, Sports medicine.

[6]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[7]  W G Hopkins,et al.  Ergometer error and biological variation in power output in a performance test with three cycle ergometers. , 2006, International journal of sports medicine.

[8]  M. L. Hull,et al.  Rider/Bicycle Interaction Loads during Standing Treadmill Cycling , 1993 .

[9]  M L Hull,et al.  The influence of pedaling rate on bilateral asymmetry in cycling. , 1999, Journal of biomechanics.

[10]  A M Nevill,et al.  Identifying home advantage in international tennis and golf tournaments. , 1997, Journal of sports sciences.

[11]  R. Davison,et al.  The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter. , 2000, International journal of sports medicine.

[12]  P. Cavanagh,et al.  Asymmetry in bicycle ergometer pedalling. , 1976, Medicine and science in sports.

[13]  M L Hull,et al.  The effect of rider weight on rider-induced loads during common cycling situations. , 1995, Journal of biomechanics.

[14]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[15]  Shauna L. Stephens,et al.  Accuracy of SRM and power tap power monitoring systems for bicycling. , 2004, Medicine and science in sports and exercise.

[16]  James C Martin,et al.  Validation of a Mathematical Model for Road Cycling Power. , 1998, Journal of applied biomechanics.

[17]  S Duc,et al.  Validity and reliability of the Axiom PowerTrain cycle ergometer when compared with an SRM powermeter. , 2005, International journal of sports medicine.

[18]  Louis Passfield,et al.  The dynamic calibration of bicycle power measuring cranks , 1998 .