Spectral and spatial dependence of diffuse optical signals in response to peripheral nerve stimulation
暂无分享,去创建一个
Yunjie Tong | Sergio Fantini | Debbie K. Chen | Angelo Sassaroli | Peter R. Bergethon | M. Kelley Erb | Yang Yu | S. Fantini | A. Sassaroli | P. Bergethon | Y. Tong | D. K. Chen | M. Erb | Yang Yu
[1] Sergio Fantini,et al. Perturbation theory for the diffusion equation by use of the moments of the generalized temporal point-spread function. I. Theory. , 2006, Journal of the Optical Society of America. A, Optics, image science, and vision.
[2] F. Martelli,et al. Perturbation theory for the diffusion equation by use of the moments of the generalized temporal point-spread function. II. Continuous-wave results. , 2006, Journal of the Optical Society of America. A, Optics, image science, and vision.
[3] Roy G. M. Kolkman,et al. In vivo photoacoustic imaging of blood vessels using an extreme-narrow aperture sensor , 2003 .
[4] C. Schmidt,et al. Relationship of oxygen tension to hemoglobin oxygen saturation in the arterial blood of normal men. , 1952, Journal of applied physiology.
[5] T. Ono,et al. Brain Cortical Mapping by Simultaneous Recording of Functional Near Infrared Spectroscopy and Electroencephalograms from the Whole Brain During Right Median Nerve Stimulation , 2009, Brain Topography.
[6] Sergio Fantini,et al. Diffuse optical signals in response to peripheral nerve stimulation reflect skeletal muscle kinematics , 2010, Biomedical optics express.
[7] Sergio Fantini,et al. Higher-order perturbation theory for the diffusion equation in heterogeneous media: application to layered and slab geometries. , 2009, Applied optics.
[8] M. J. Blunt. The vascular anatomy of the median nerve in the forearm and hand. , 1959, Journal of anatomy.
[9] A. Halim,et al. Dependence of human forearm skin postocclusive reactive hyperemia on occlusion time. , 2004, Journal of pharmacological and toxicological methods.
[10] Sergio Fantini,et al. Near-infrared signals associated with electrical stimulation of peripheral nerves , 2009, BiOS.
[11] James S. Schwaber,et al. Scattered-Light Imaging in Vivo Tracks Fast and Slow Processes of Neurophysiological Activation , 2001, NeuroImage.
[12] E. Gratton,et al. Cerebral and muscle oxygen saturation measurement by frequency-domain near-infra-red spectrometer , 1995, Medical and Biological Engineering and Computing.
[13] Yunjie Tong,et al. Fast optical response to electrical activation in peripheral nerves , 2007, SPIE BiOS.
[14] B. Vallée,et al. Anatomic basis of vascularised nerve grafts: the blood supply of peripheral nerves , 1999, Surgical and Radiologic Anatomy.
[15] Hellmuth Obrig,et al. The fast optical signal—Robust or elusive when non-invasively measured in the human adult? , 2005, NeuroImage.
[16] G. Curio,et al. Somatosensory evoked fast optical intensity changes detected non-invasively in the adult human head , 2000, Neuroscience Letters.
[17] Hanli Liu,et al. Near infrared and visible spectroscopic measurements to detect changes in light scattering and hemoglobin oxygen saturation from rat spinal cord during peripheral stimulation , 2008, NeuroImage.
[18] Blake D. Niederhauser,et al. A Functional Near-infrared Spectroscopy Study to Detect Activation of Somatosensory Cortex by Peripheral Nerve Stimulation , 2008, Neurocritical care.
[19] Gianpaolo Donzelli,et al. Optical study of the skeletal muscle during exercise with a second-generation frequency-domain tissue oximeter , 1997, Photonics West - Biomedical Optics.
[20] Sergio Fantini,et al. Mathematical Model for the Hemodynamic Response to Venous Occlusion Measured With Near-Infrared Spectroscopy in the Human Forearm , 2007, IEEE Transactions on Biomedical Engineering.
[21] E. Beutler,et al. The definition of anemia: what is the lower limit of normal of the blood hemoglobin concentration? , 2006, Blood.
[22] Yunjie Tong,et al. Fast optical signals in the peripheral nervous system. , 2006, Journal of biomedical optics.
[23] Ron A. Wevers,et al. Validation of measurement protocols to assess oxygen consumption and blood flow in the human forearm by near-infrared spectroscopy , 1998, European Conference on Biomedical Optics.
[24] Solomiya Lebid,et al. Towards dual modality nerve assessment using electrical and optical techniques , 2005, International Conference on Optical Fibre Sensors.
[25] Non-Invasive Measurement of Skeletal Muscle Contraction with Time-Resolved Diffusing-Wave Spectroscopy , 2010 .
[26] David A Boas,et al. Noninvasive measurement of neuronal activity with near-infrared optical imaging , 2004, NeuroImage.
[27] E Gratton,et al. Blood flow and oxygen consumption with near-infrared spectroscopy and venous occlusion: spatial maps and the effect of time and pressure of inflation. , 2000, Journal of biomedical optics.
[28] S. Aiso,et al. Accompanying arteries of the lesser saphenous vein and sural nerve: anatomic study and its clinical applications. , 1999, Plastic and reconstructive surgery.
[29] S. Arridge,et al. Estimation of optical pathlength through tissue from direct time of flight measurement , 1988 .
[30] Marco Ferrari,et al. Spatial distribution of vastus lateralis blood flow and oxyhemoglobin saturation measured at the end of isometric quadriceps contraction by multichannel near-infrared spectroscopy. , 2004, Journal of biomedical optics.
[31] Nicolas Brieu,et al. Optical imaging of vascular and metabolic responses in the lumbar spinal cord after T10 transection in rats , 2009, Neuroscience Letters.
[32] David A. Boas,et al. Fast optical signal not detected in awake behaving monkeys , 2008, NeuroImage.
[33] R. Cubeddu,et al. In vivo absorption and scattering spectroscopy of biological tissues , 2003, Photochemical & photobiological sciences : Official journal of the European Photochemistry Association and the European Society for Photobiology.
[34] Katsushige Sato,et al. Optical Imaging of Intrinsic Signals Induced by Peripheral Nerve Stimulation in the in Vivo Rat Spinal Cord , 2002, NeuroImage.
[35] C. Piantadosi,et al. Near infrared monitoring of human skeletal muscle oxygenation during forearm ischemia. , 1988, Journal of applied physiology.
[36] Fu Li,et al. The blood vessels and nerves of the dorsalis pedis flap , 1989 .
[37] M. Ferrari,et al. Noninvasive measurement of cerebral hemoglobin oxygen saturation using two near infrared spectroscopy approaches. , 2000, Journal of biomedical optics.
[38] T Binzoni,et al. Oxidative metabolism in muscle. , 1997, Philosophical transactions of the Royal Society of London. Series B, Biological sciences.