Artificial pollution flashover performance of porcelain long rod UHVDC insulators at high altitudes

Porcelain long rod insulators are recommended for outdoor insulation of UHV/EHV dc transmission lines because of their excellent service experience obtained in Central Europe. However, very few studies have been conducted on dc pollution flashover performance or the UHVDC insulators at high altitudes. Artificial pollution tests on 300 kN and above porcelain long rod insulators were carried out with dc voltage in natural high altitude areas (about 2000 m), in which the solid layer method was used and the 50% flashover voltage (U50%) was measured with the up-and-down method. Test results show that dc pollution flashover performances of the 300 and 400 kN insulators are similar. The exponents characterizing influence of salt deposit density on the flashover voltage vary from 0.46 to 0.57. A nearly linear relationship between the flashover voltage and the string length of the insulators is presented. Both double suspension strings and tension string patterns have a significant influence on the flashover voltage. The influence of non-uniform pollution distribution between the top and bottom surfaces of the insulator sheds on the flashover voltage is analyzed, and a correction coefficient for the insulators is proposed.

[1]  Zhicheng Guan,et al.  Study on process of DC pollution flashover of porcelain insulators of parallel double-strings form at high altitude , 2009, 2009 IEEE Conference on Electrical Insulation and Dielectric Phenomena.

[2]  T. Cheng,et al.  Pollution Performance of DC Insulators under Operating Conditions , 1981, IEEE Transactions on Electrical Insulation.

[3]  W. Lampe,et al.  Long-term tests of HVDC insulators under natural pollution conditions at the Big Eddy Test Center , 1989 .

[4]  Lin Yang,et al.  Comparison of pollution flashover performance of porcelain long rod, disc type, and composite UHVDC insulators at high altitudes , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[5]  Ruihai Li,et al.  Effect of arcing on DC flashover performance of contaminated porcelain insulators for various suspension patterns at high altitudes , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[6]  J.M. Seifert,et al.  A comparison of the pollution performance of long rod and disc type HVDC insulators , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.

[7]  Zhicheng Guan,et al.  Experimental Investigation on Outdoor Insulation for DC Transmission Line at High Altitudes , 2010, IEEE Transactions on Power Delivery.

[8]  E. Bauer,et al.  Porcelain and Composite Longrod Insulatoes - A Solution for Future Line Requirements , 1981, IEEE Transactions on Electrical Insulation.

[9]  T. Shindo,et al.  Natural contamination test of insulators with DC voltage energization at inland areas , 1988 .

[10]  Chen Yuan Polarity effect of DC contamination flashover of composite insulators , 1999 .

[11]  Liming Wang,et al.  Influence of composite insulator shed design on contamination flashover performance at high altitudes , 2011, IEEE Transactions on Dielectrics and Electrical Insulation.

[12]  Seiichi Kondo,et al.  Study on Pollution Performance and Insulation Selection of ±800 kV Long String Insulators , 2009 .

[13]  T. Fujimura The evolution of porcelain insulator technology in Japan , 1995 .

[14]  Xingliang Jiang,et al.  Investigation of flashover voltage and non-uniform pollution correction coefficient of short samples of composite insulator intended for ±800kV UHVDC , 2010, IEEE Transactions on Dielectrics and Electrical Insulation.

[15]  Luo Bing Experimental Investigation of Electric Linear Characteristics of UHVDC Composite Insulators , 2006 .