Performance of cooled-ceiling operating with MPCM slurry

Microencapsulated phase change material (MPCM) slurry is advantageous for thermal storage systems to use as a heat transfer and storage medium. In this paper, a new design of air-conditioning system is proposed, which is a combination of CC and a MPCM slurry storage tank. The mathematical model of the combined system is provided and used to predict the system performance of an office room under Hong Kong weather condition using hour-by-hour calculations. A feasibility analysis for the combined system was also made with computer calculations. The results indicate that a small MPCM slurry storage tank is able to shift the part of cooling load from the daytime to nighttime. It is also revealed that the proposed combined system is an energy saving and economy-favorable air-conditioning system.

[1]  Binjiao Chen,et al.  Flow and heat transfer behaviors of phase change material slurries in a horizontal circular tube , 2007 .

[2]  M. M. Chen,et al.  Microconvective Thermal Conductivity in Disperse Two-Phase Mixtures as Observed in a Low Velocity Couette Flow Experiment , 1981 .

[3]  M. M. Chen,et al.  Improvement of the Performance of Solar Energy or Waste Heat Utilization Systems by Using Phase-Change Slurry as an Enhanced Heat-Transfer Storage Fluid , 1985 .

[4]  H. Takeuchi,et al.  An evaluation of microencapsulated PCM for use in cold energy transportation medium , 1996, IECEC 96. Proceedings of the 31st Intersociety Energy Conversion Engineering Conference.

[5]  Graeme Maidment,et al.  A review of research concerning the use of PCMS in air conditioning and refrigeration engineering , 2002 .

[6]  Donal Finn,et al.  Indirect evaporative cooling potential in air-water systems in temperate climates , 2003 .

[7]  Hideo Inaba,et al.  Melting Heat Transfer Characteristics of Microencapsulated Phase Change Material Slurries With Plural Microcapsules Having Different Diameters , 2004 .

[8]  Toshiaki Omori,et al.  Thermal comfort and energy consumption of the radiant ceiling panel system.: Comparison with the conventional all-air system , 1999 .

[9]  S. A. Mumma Backup Condensation Control Via Portal Sensors , 2005 .

[10]  Jianlei Niu,et al.  Energy savings potential of chilled-ceiling combined with desiccant cooling in hot and humid climates , 2002 .

[11]  Jianlei Niu,et al.  Indoor climate in rooms with cooled ceiling systems , 1994 .

[12]  End Use Annual energy review , 1984 .

[13]  Xianxu Hu,et al.  Novel insight and numerical analysis of convective heat transfer enhancement with microencapsulated phase change material slurries: laminar flow in a circular tube with constant heat flux , 2002 .

[14]  Tatsuo Oka,et al.  Performance of radiant cooling system integrated with ice storage , 1999 .

[15]  S. Maithel Energy Efficiency and Renewable Energy , 2008 .

[16]  Yi Li,et al.  Heat transfer of microencapsulated PCM slurry flow in a circular tube , 2008 .

[17]  Amar M. Khudhair,et al.  A review on phase change energy storage: materials and applications , 2004 .

[18]  Jelena Srebric,et al.  A critical review on the performance and design of combined cooled ceiling and displacement ventilation systems , 2002 .

[19]  Jianlei Niu,et al.  ENERGY SAVING POSSIBILITIES WITH COOLED-CEILING SYSTEMS , 1995 .

[20]  P. F. Grigg,et al.  Chilled ceilings and displacement ventilation , 1998 .

[21]  P. Charunyakorn,et al.  Forced convection heat transfer in microencapsulated phase change material slurries: flow in circular ducts , 1991 .

[22]  R. Holmen,et al.  Measurements of the Thermal Conductivities of Solid and Liquid Unbranched Alkanes in the C16-to-C19 Range During Phase Transition , 2002 .

[23]  John Aurie Dean,et al.  Lange's Handbook of Chemistry , 1978 .

[24]  Amir Faghri,et al.  Analysis of Forced Convection Heat Transfer in Microencapsulated Phase Change Material Suspensions , 1995 .

[25]  Helmut E. Feustel,et al.  Hydronic radiant cooling — preliminary assessment☆ , 1995 .

[26]  A. Bejan,et al.  Heat transfer handbook , 2003 .

[27]  Dennis L. Loveday,et al.  Thermal comfort in chilled ceiling and displacement ventilation environments: vertical radiant temperature asymmetry effects , 1998 .

[28]  Saffa Riffat,et al.  Numerical simulation of closed wet cooling towers for chilled ceiling systems , 1999 .

[29]  S. Sengupta,et al.  Laminar forced convection heat transfer in microcapsulated phase change material suspensions , 1994 .

[30]  Jianlei Niu,et al.  Cooling load dynamics of rooms with cooled ceilings , 1997 .

[31]  N. Kayukawa,et al.  Characteristics of microencapsulated PCM slurry as a heat‐transfer fluid , 1999 .