Thermal evaluation of a Room coupled with a Double Glazing Window with/without a solar control film for Mexico

Abstract The thermal evaluation of a Room (R) coupled with a Double Glazing Window (DGW) with/without solar control film (SCF) under warm and cold climate conditions of an extreme weather of Mexico is presented. The right vertical wall of the room is partially adiabatic and contains the DGW. The DGW consists of two vertical semitransparent walls: glazing-1 facing the room, and glazing-2 facing the external environment. The SCF is attached to glazing-1 for cold climate condition, or attached to glazing-2 for warm climate condition. During one day, hourly simulations of the R-DGW were done using an in-house code based on the finite volume method. Three cases were defined to analyze the R-DGW system: Case C1 corresponds to the R-DGW without SCF; Case C2 and C3 correspond to the R-DGW with SCF for warm and cold climate conditions, respectively. For warm climate condition the use of a SCF is highly recommended, since the Case C2 was able to reduce ≈62% of the energy gains with respect to Case C1. When the solar control coating in double glass window is used for cold climate condition (case C3), the average temperature inside of the room is similar to the case C1.

[1]  Isabel Pérez-Grande,et al.  Influence of glass properties on the performance of double-glazed facades , 2005 .

[2]  Hasan Karabay,et al.  Multiple pane window applications in various climatic regions of Turkey , 2012 .

[3]  Guohui Gan,et al.  Thermal transmittance of multiple glazing: computational fluid dynamics prediction , 2001 .

[4]  Vítor Leal,et al.  “SOLVENT”: development of a reversible solar-screen glazing system , 2004 .

[5]  C. J. Hoogendoorn,et al.  Natural-convection flow in a square cavity calculated with low-Reynolds-number turbulence models , 1991 .

[6]  A. Schaelin,et al.  Airflow patterns and thermal behavior of mechanically ventilated glass double façades , 2004 .

[7]  Jorge S. Carlos,et al.  Modelling and simulation of a ventilated double window , 2011 .

[8]  Hasan Karabay,et al.  Determination of optimum thickness of double-glazed windows for the climatic regions of Turkey , 2010 .

[9]  J. Xamán,et al.  Thermal performance of a double pane window using glazing available on the Mexican market , 2015 .

[10]  E. H. Ridouane,et al.  INTERACTION BETWEEN NATURAL CONVECTION AND RADIATION IN A SQUARE CAVITY HEATED FROM BELOW , 2004 .

[11]  Fabio Bisegna,et al.  Saving energy in residential buildings: The use of fully reversible windows , 2007 .

[12]  C. Gueymard,et al.  Spectral effects on the transmittance, solar heat gain, and performance rating of glazing systems , 2009 .

[13]  M. Modest Radiative heat transfer , 1993 .

[14]  Jorge S. Carlos,et al.  Evaluation of the thermal performance indices of a ventilated double window through experimental and analytical procedures: Uw-values , 2014 .

[15]  Wei He,et al.  Use of ventilated solar screen window in warm climate , 2006 .

[16]  Orhan Aydin,et al.  Determination of optimum air-layer thickness in double-pane windows , 2000 .

[17]  J. P. V. Doormaal,et al.  ENHANCEMENTS OF THE SIMPLE METHOD FOR PREDICTING INCOMPRESSIBLE FLUID FLOWS , 1984 .

[18]  S. Patankar Numerical Heat Transfer and Fluid Flow , 2018, Lecture Notes in Mechanical Engineering.

[19]  Kamal Abdel Radi Ismail,et al.  Simplified model for a ventilated glass window under forced air flow conditions , 2006 .

[20]  Tian-Peng Wang,et al.  A steady heat transfer model of hollow double glazing under entire wave length heat radiation , 2014 .

[21]  Orhan Aydin,et al.  Conjugate heat transfer analysis of double pane windows , 2006 .

[22]  Jorge S. Carlos,et al.  Real climate experimental study of two double window systems with preheating of ventilation air , 2010 .

[23]  Evyatar Erell,et al.  Controlling the transmission of radiant energy through windows: a novel ventilated reversible glazing system , 2000 .

[24]  Kankanhalli N. Seetharamu,et al.  Interaction Effects Between Surface Radiation and Turbulent Natural Convection in Square and Rectangular Enclosures , 2001 .

[25]  Peng Xu,et al.  Case study: Energy savings from solar window film in two commercial buildings in Shanghai , 2012 .

[26]  J. Xamán,et al.  Effect of Heat Conduction of SnS-Cu x S Solar Control Coated Semitransparent Wall on Turbulent Natural Convection in a Square Cavity , 2006 .

[27]  G. de Vahl Davis,et al.  The Method of the False Transient for the Solution of Coupled Elliptic Equations , 1973 .

[28]  J. Xamán,et al.  Thermal analysis for a double pane window with a solar control film for using in cold and warm climates , 2014 .

[29]  Kamal Abdel Radi Ismail,et al.  A comparative study of naturally ventilated and gas filled windows for hot climates , 2009 .

[30]  K. F. Fong,et al.  Thermal performance of natural airflow window in subtropical and temperate climate zones – A comparative study , 2009 .

[31]  Müslüm Arıcı,et al.  An investigation of flow and conjugate heat transfer in multiple pane windows with respect to gap width, emissivity and gas filling , 2015 .

[32]  Daniel Feuermann,et al.  Reversible low solar heat gain windows for energy savings , 1998 .

[33]  P K Nair,et al.  SnS-CuxS thin film combination: a desirable solar control coating for architectural and automobile glazings , 1991 .