Online Frequency Response Analysis of Electric Machinery through an Active Coupling System Based on Power Electronics
暂无分享,去创建一个
Erik Leandro Bonaldi | Germano Lambert-Torres | Mateus Mendes Campos | Daniel de Almeida Arantes | Wilson Cesar Sant’Ana | Bruno Reno Gama | Tiago Goncalves Zacarias | Isac Antonio dos Santos Areias | Frederico de Oliveira Assuncao | Fabio Monteiro Steiner | Fabio M. Steiner | Wilson C. Sant’ana | G. Lambert-Torres | E. Bonaldi | F. Assunção | I. A. S. Areias | Tiago Gonçalves Zacarias | D. A. Arantes | B. R. Gama
[1] G. Ragsdell. Systems , 2002, Economics of Visual Art.
[2] J. Steckel,et al. Beamforming Applied to Ultrasound Analysis in Detection of Bearing Defects , 2021, Sensors.
[3] Maryam Saeedifard,et al. Operation, Control, and Applications of the Modular Multilevel Converter: A Review , 2015, IEEE Transactions on Power Electronics.
[4] Saeed Alyami,et al. Application of Frequency Response Analysis Technique to Detect Transformer Tap Changer Faults , 2021 .
[5] C A Platero,et al. Influence of Rotor Position in FRA Response for Detection of Insulation Failures in Salient-Pole Synchronous Machines , 2011, IEEE Transactions on Energy Conversion.
[6] Paolo Giangrande,et al. Evaluation of strand‐to‐strand capacitance and dissipation factor in thermally aged enamelled coils for low‐voltage electrical machines , 2019, IET Science, Measurement & Technology.
[7] Mehdi Bagheri,et al. Loss of low-frequency data in on- line frequency response analysis of transformers , 2017, IEEE Electrical Insulation Magazine.
[8] Germano Lambert-Torres,et al. Development of a Modular Educational Kit for Research and Teaching on Power Electronics and Multilevel Converters , 2021, IEEE Access.
[10] Kamal Al-Haddad,et al. A review of active filters for power quality improvement , 1999, IEEE Trans. Ind. Electron..
[11] Ahmed Abu-Siada,et al. Fault Diagnosis of Transformer Windings Based on Decision Tree and Fully Connected Neural Network , 2021, Energies.
[12] F. Blaabjerg,et al. Detection is key - Harmonic detection methods for active power filter applications , 2007, IEEE Industry Applications Magazine.
[13] Germano Lambert-Torres,et al. A system for turbogenerator predictive maintenance based on Electrical Signature Analysis , 2015, 2015 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings.
[14] Rajesh Rajamani,et al. Extended Application for the Impulse-Based Frequency Response Analysis: Preliminary Diagnosis of Partial Discharges in Transformer , 2020, IEEE Access.
[15] Germano Lambert-Torres,et al. Equipment for Predictive Maintenance in Hydrogenerators , 2014 .
[16] Erik Leandro Bonaldi,et al. A survey on statistical indexes applied on frequency response analysis of electric machinery and a trend based approach for more reliable results , 2016 .
[17] Erik Leandro Bonaldi,et al. Development and 24 Hour Behavior Analysis of a Peak-Shaving Equipment with Battery Storage , 2019, Energies.
[18] Germano Lambert-Torres,et al. FPGA Prototyping Using the STEMlab Board With Application on Frequency Response Analysis of Electric Machinery , 2021, IEEE Access.
[19] F. R. Blanquez,et al. Evaluation of the applicability of FRA for inter-turn fault detection in stator windings , 2013, 2013 9th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives (SDEMPED).
[20] S. V. Kulkarni,et al. Alternative statistical techniques for aiding SFRA diagnostics in transformers , 2012 .
[21] Germano Lambert-Torres,et al. On the use of hypothesis tests as statistical indexes for frequency response analysis of electric machinery , 2017 .
[22] Hassan Ezzaidi,et al. Frequency Response Analysis Interpretation Using Numerical Indices and Machine Learning: A Case Study Based on a Laboratory Model , 2021, IEEE Access.
[23] A. Abu-Siada,et al. Understanding the Influence of Power Transformer Faults on the Frequency Response Signature Using Simulation Analysis and Statistical Indicators , 2021, IEEE Access.
[24] Guillermo Aponte Mayor,et al. Current Status and Future Trends in Frequency-Response Analysis With a Transformer in Service , 2013, IEEE Transactions on Power Delivery.
[25] P. Picher,et al. Impedance Characterization of Hydro Generator Stator Windings and Preliminary Results of FRA Analysis , 2008, Conference Record of the 2008 IEEE International Symposium on Electrical Insulation.
[26] Piotr Kaczmarek,et al. EMC of Wideband Power Sources , 2021, Energies.
[27] S. A. Ryder,et al. Diagnosing transformer faults using frequency response analysis , 2003 .
[28] Chenguo Yao,et al. Improved Method to Obtain the Online Impulse Frequency Response Signature of a Power Transformer by Multi Scale Complex CWT , 2018, IEEE Access.
[29] Erik Leandro Bonaldi,et al. A Study of Fault Diagnosis Based on Electrical Signature Analysis for Synchronous Generators Predictive Maintenance in Bulk Electric Systems , 2019, Energies.
[30] Steve Mitchell,et al. The application of sweep frequency response analysis for the online monitoring of power transformers , 2016, 2016 Australasian Universities Power Engineering Conference (AUPEC).
[31] José Ángel Sánchez-Fernández,et al. Fluid Degradation Measurement Based on a Dual Coil Frequency Response Analysis , 2020, Sensors.
[32] Samih M. Mostafa,et al. An Expert System for Rotating Machine Fault Detection Using Vibration Signal Analysis , 2021, Sensors.
[33] D. Roger,et al. A New Method for AC Machine Turn Insulation Diagnostic Based on High Frequency Resonances , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.
[34] Jong-Wook Kim,et al. Fault diagnosis of a power transformer using an improved frequency-response analysis , 2005, IEEE Transactions on Power Delivery.
[35] Germano Lambert-Torres,et al. Early detection of insulation failures on electric generators through online Frequency Response Analysis , 2016 .
[36] Bhavesh R Bhalja,et al. Approach for Identification of Inter-Turn Fault Location in Transformer Windings Using Sweep Frequency Response Analysis , 2021, IEEE Transactions on Power Delivery.
[37] Germano Lambert-Torres,et al. 13.8 kV Operation of a Peak-Shaving Energy Storage Equipment With Voltage Harmonics Compensation Feature , 2020, IEEE Access.
[38] Erik Leandro Bonaldi,et al. Influence of rotor position on the repeatability of frequency response analysis measurements on rotating machines and a statistical approach for more meaningful diagnostics , 2016 .
[39] Dianguo Xu,et al. Analysis of the Phase-Shifted Carrier Modulation for Modular Multilevel Converters , 2015, IEEE Transactions on Power Electronics.
[40] Mehdi Bagheri,et al. Influence of temperature and moisture content on frequency response analysis of transformer winding , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.
[41] Enrique E. Mombello,et al. Sweep frequency response analysis (SFRA) for the assessment of winding displacements and deformation in power transformers , 2008 .
[42] Krzysztof Praznowski,et al. Motion Magnification of Vibration Image in Estimation of Technical Object Condition-Review , 2021, Sensors.
[43] Erik Leandro Bonaldi,et al. Condition Monitoring of Internal Combustion Engines in Thermal Power Plants Based on Control Charts and Adapted Nelson Rules , 2021, Energies.
[44] A A Reykherdt,et al. Case studies of factors influencing frequency response analysis measurements and power transformer diagnostics , 2011, IEEE Electrical Insulation Magazine.