High-resolution Computed Tomography Imaging of Airway Disease in Infants with Cystic

To objectively quantify airway geometry from three-dimensional computed tomographic (CT) images, an idealized (circular cross section) airway model is parameterized by airway luminal caliber, wall thickness, and tilt angle. Using a two-dimensional CT slice, an initial guess for the airway center, and the full-width-half-maximum principle, we form an estimate of inner and outer airway wall locations. We then fit ellipses to the inner and outer airway walls via a direct least squares fit and use the major and minor axes of the ellipses to estimate the tilt and in-plane rotation angles. Convolving the airway model, initialized with these estimates, with the three-dimensional scanner point-spread function forms the predicted image. The difference between predicted and actual images is minimized by refining the model parameter estimates via a multidimensional, unconstrained, nonlinear minimization routine. When optimization converges, airway model parameters estimate the airway inner and outer radii and tilt angle. Results using a Plexiglas phantom show that tilt angle is estimated to within +/-4 degrees and both inner and outer radii to within one-half pixel when a "standard" CT reconstruction kernel is used. By opening up the ability to measure airways that are not oriented perpendicular to the scanning plane, this method allows evaluation of a greater sampling of airways in a two-dimensional CT slice than previously possible. In addition, by combining the tilt-angle compensation with the deconvolution method, we provide significant improvement over the previous full-width-half-maximum method for assessing location of the luminal edge but not the outer edge of the airway wall.

[1]  John A. Nelder,et al.  A Simplex Method for Function Minimization , 1965, Comput. J..

[2]  M. King,et al.  SPECT volume quantitation: influence of spatial resolution, source size and shape, and voxel size. , 1991, Medical physics.

[3]  Andrew W. Fitzgibbon,et al.  Direct Least Square Fitting of Ellipses , 1999, IEEE Trans. Pattern Anal. Mach. Intell..

[4]  G Cumming,et al.  Diameter, length and branching ratios in the bronchial tree. , 1976, Respiration physiology.

[5]  P. Paré,et al.  Human airway narrowing measured using high resolution computed tomography. , 1996, American journal of respiratory and critical care medicine.

[6]  E L Nickoloff,et al.  Measurement of the PSF for a CT scanner: appropriate wire diameter and pixel size. , 1988, Physics in medicine and biology.

[7]  Milan Sonka,et al.  Intrathoracic airway wall detection using graph search and scanner PSF information , 1997, Medical Imaging.

[8]  K P Whittall,et al.  An analysis algorithm for measuring airway lumen and wall areas from high-resolution computed tomographic data. , 2000, American journal of respiratory and critical care medicine.

[9]  R. Brown,et al.  The myth of maximal airway responsiveness in vivo. , 1998, Journal of applied physiology.

[10]  Eric A. Hoffman,et al.  ASAP: interactive quantification of 2D airway geometry , 1996, Medical Imaging.

[11]  Milan Sonka,et al.  Segmentation of intrathoracic airway trees: a fuzzy logic approach , 1998, IEEE Transactions on Medical Imaging.

[12]  G Gamsu,et al.  CT of a bronchial phantom. Factors affecting appearance and size measurements. , 1984, Investigative radiology.

[13]  K. Horsfield,et al.  Branching angles in the bronchial tree related to order of branching. , 1980, Respiration physiology.

[14]  E A Zerhouni,et al.  In vivo measurements of airway reactivity using high-resolution computed tomography. , 1991, The American review of respiratory disease.

[15]  H Kitaoka,et al.  A three-dimensional model of the human airway tree. , 1999, Journal of applied physiology.

[16]  Ge Wang,et al.  Spiral CT image deblurring for cochlear implantation , 1998, IEEE Transactions on Medical Imaging.

[17]  Eric A. Hoffman,et al.  Accurate measurement of intrathoracic airways , 1997, IEEE Transactions on Medical Imaging.

[18]  Geoffrey McLennan,et al.  Three-dimensional human airway segmentation methods for clinical virtual bronchoscopy. , 2002, Academic radiology.

[19]  Guang-Zhong Yang,et al.  ERS transform for the automated detection of bronchial abnormalities on CT of the lungs , 2001, IEEE Transactions on Medical Imaging.

[20]  E. Sorantin,et al.  Spiral-CT-based assessment of tracheal stenoses using 3-D-skeletonization , 2002, IEEE Transactions on Medical Imaging.

[21]  E A Hoffman,et al.  A method for measurement of cross sectional area, segment length, and branching angle of airway tree structures in situ. , 1995, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[22]  J Bousquet,et al.  Measurement of the internal size of bronchi using high resolution computed tomography (HRCT) , 1994, The European respiratory journal.

[23]  E. Weibel Morphometry of the Human Lung , 1965, Springer Berlin Heidelberg.

[24]  Andrew W. Fitzgibbon,et al.  Direct least squares fitting of ellipses , 1996, Proceedings of 13th International Conference on Pattern Recognition.

[25]  P. Paré,et al.  Airway narrowing in excised canine lungs measured by high-resolution computed tomography. , 1992, Journal of applied physiology.

[26]  N L Müller,et al.  Airway wall thickness in patients with near fatal asthma and control groups: assessment with high resolution computed tomographic scanning , 1998, Thorax.

[27]  M W Skinner,et al.  Temporal bone volumetric image deblurring in spiral computed tomography scanning. , 1995, Academic radiology.

[28]  Françoise J. Prêteux,et al.  Modeling, segmentation, and caliber estimation of bronchi in high resolution computerized tomography , 1999, J. Electronic Imaging.

[29]  G Wang,et al.  Longitudinal image deblurring in spiral CT. , 1994, Radiology.

[30]  V. Sauret,et al.  Semi-automated tabulation of the 3D topology and morphology of branching networks using CT: application to the airway tree. , 1999, Physics in medicine and biology.

[31]  Eric A. Hoffman,et al.  Intrathoracic airway measurement: ex-vivo validation , 1997, Medical Imaging.

[32]  E A Zerhouni,et al.  Variability in the size of individual airways over the course of one year. , 1995, American journal of respiratory and critical care medicine.

[33]  L. D. Harris,et al.  Quantitative Analysis of a Vascular Tree Model with the Dynamic Spatial Reconstructor , 1984, Journal of computer assisted tomography.

[34]  J G Goldin,et al.  Development and testing of image-processing methods for the quantitative assessment of airway hyperresponsiveness from high-resolution CT images. , 1997, Journal of computer assisted tomography.

[35]  W. Chang Slice characteristics of the Imatron Cine-CT scanner. , 1987, Journal of computer assisted tomography.

[36]  W E Higgins,et al.  Distributed system for processing 3D medical images , 1997, Comput. Biol. Medicine.

[37]  E A Hoffman,et al.  Assessment of methacholine-induced airway constriction by ultrafast high-resolution computed tomography. , 1993, Journal of applied physiology.

[38]  E A Hoffman,et al.  Measurement of three-dimensional lung tree structures by using computed tomography. , 1995, Journal of applied physiology.