Rehabilitation Robotics: a Wearable Exo-Skeleton for Tremor Assessment and Suppression

There is a need for wearable powered upper limb exoskeletons able to apply forces to the upper limb for use by people with disabilities and/or limb weakness or injury. The robotic exoskeleton called WOTAS (Wearable Orthosis for Tremor Assessment and Suppression) presented in this paper will provide a means of testing non-grounded control strategies in order to help these people. For instance, biomechanical loading, in particular, viscous loading of the upper limb has been proposed in the literature as a means for suppressing pathologic tremor. This article describes in detail the general concept for WOTAS, outlining the special features of the design and selection of system components.

[1]  M H Granat,et al.  A practical gait analysis system using gyroscopes. , 1999, Medical engineering & physics.

[2]  T A Krouskop,et al.  Effectiveness of mattress overlays in reducing interface pressures during recumbency. , 1985, Journal of rehabilitation research and development.

[3]  Neville Hogan,et al.  Impedance Control: An Approach to Manipulation: Part I—Theory , 1985 .

[4]  W. Koller,et al.  Tremor disorders. Diagnosis and management. , 1995, The Western journal of medicine.

[5]  José Luis Pons Rovira,et al.  The MANUS-HAND Dextrous Robotics Upper Limb Prosthesis: Mechanical and Manipulation Aspects , 2004, Auton. Robots.

[6]  L. Cocchiarella,et al.  Guides to the evaluation of permanent impairment , 2000 .

[7]  M. Hallett Tremor , 1991, Neurology.

[8]  G R Johnson,et al.  The design of a five-degree-of-freedom powered orthosis for the upper limb , 2001, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[9]  I. Kapandji The Physiology of the Joints , 1988 .

[10]  C. S. G. Lee,et al.  Robotics: Control, Sensing, Vision, and Intelligence , 1987 .

[11]  P. Leva Adjustments to Zatsiorsky-Seluyanov's segment inertia parameters. , 1996 .

[12]  Neville Hogan,et al.  Impedance Control: An Approach to Manipulation , 1984, 1984 American Control Conference.

[13]  M. Topping,et al.  Dynamically responsive intervention for tremor suppression , 2003, IEEE Engineering in Medicine and Biology Magazine.

[14]  William S. Harwin,et al.  Clinical potential and design of programmable mechanical impedances for orthotic applications , 1998, Robotica.

[15]  Eduardo Rocon,et al.  Pathological tremor management: Modelling, compensatory technology and evaluation , 2004 .

[16]  Ravindra S. Goonetilleke,et al.  Designing to Miminize Discomfort , 1998 .

[17]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.