Electrospray ionization with ambient pressure ion mobility separation and mass analysis by orthogonal time-of-flight mass spectrometry.

Rapid screening and identification of drug and other mixtures are possible using a novel ambient pressure high-resolution ion mobility (APIMS) orthogonal reflector time-of-flight mass spectrometer (TOFMS). Departing ions from the APIMS drift tube traversed a pressure interface between the APIMS and TOFMS where they were subjected to numerous gas collisions that could produce selective fragmentation. By increasing the accelerating field in the pressure interface region, the ions generated using water-cooled electrospray ionization (ESI) underwent collision-induced dissociation (CID). Mixtures of ESI ions were separated by APIMS based on their respective size-to-charge (s/z) ratios while CID and analysis of mass-to-charge (m/z) ratios occurred in the pressure interface and TOFMS. Product ions that were formed in this pressure interface region could be readily assigned to precursor ions by matching the mobility drift times. This process was demonstrated by the examination of a mixture of amphetamines and the resulting fragmentation patterns of the mobility-separated precursor ion species [M + H](+).

[1]  J P Reilly,et al.  Three-dimensional ion mobility/TOFMS analysis of electrosprayed biomolecules. , 1998, Analytical chemistry.

[2]  D. Clemmer,et al.  Mobility labeling for parallel CID of ion mixtures. , 2000, Analytical chemistry.

[3]  G. Spangler Characterization of the ion-sampling pinhole interface for an ion mobility spectrometer/mass spectrometer system , 2001 .

[4]  B. Ruotolo,et al.  Coupling high-pressure MALDI with ion mobility/orthogonal time-of-flight mass spectrometry. , 2000, Analytical chemistry.

[5]  Ming-Teh Hsu,et al.  Structures of carbon cluster ions from 3 to 60 atoms: Linears to rings to fullerenes , 1991 .

[6]  R. Purves,et al.  MASS SPECTROMETRIC CHARACTERIZATION OF A HIGH-FIELD ASYMMETRIC WAVEFORM ION MOBILITY SPECTROMETER , 1998 .

[7]  L. Ding,et al.  Combined Ion Mobility/Time-of-Flight Mass Spectrometry Study of Electrospray-Generated Ions. , 1997, Analytical chemistry.

[8]  S. Valentine,et al.  An Ion Trap Interface for ESI−Ion Mobility Experiments , 1997 .

[9]  Ching Wu,et al.  Measuring the Resolving Power of Ion Mobility Spectrometers , 1994 .

[10]  C. E. Young,et al.  Water Cluster Ions: Rates of Formation and Decomposition of Hydrates of the Hydronium Ion , 1970 .

[11]  H. Hill,et al.  Electrospray ionization high-resolution ion mobility spectrometry-mass spectrometry. , 1998, Analytical chemistry.

[12]  Norris E. Bradbury,et al.  Absolute Values of the Electron Mobility in Hydrogen , 1936 .

[13]  S. H. Kim,et al.  Plasma chromatography of heroin and cocaine with mass-identified mobility spectra. , 1976, Journal of chromatography.

[14]  T. Barckholtz,et al.  MEKC with bile salt micelles for the enantiomeric separation of bis(8‐((pyridine‐2‐methylene)amino)quinoline)iron(II) hexafluorophosphate: Kinetics and mechanism of the racemization , 2000 .