Descemet's Stripping Automated Endothelial Keratoplasty Tissue Insertion Devices

This review study provides information regarding the construction, design, and use of six commercially available endothelial allograft insertion devices applied for Descemet's stripping automated endothelial keratoplasty (DSAEK). We also highlight issues being faced in DSAEK and discuss the methods through which medical devices such as corneal inserters may alleviate these issues. Inserter selection is of high importance in the DSAEK procedure since overcoming the learning curve associated with the use of an insertion device is a time and energy consuming process. In the present review, allograft insertion devices were compared in terms of design, construction material, insertion technique, dimensions, incision requirements and endothelial cell loss to show their relative merits and capabilities based on available data in the literature. Moreover, the advantages/disadvantages of various insertion devices used for allograft insertion in DSAEK are reviewed and compared. The information presented in this review can be utilized for better selection of an insertion device for DSAEK.

[1]  M. Terry,et al.  Endothelial keratoplasty: prospective, randomized, masked clinical trial comparing an injector with forceps for tissue insertion. , 2013, American journal of ophthalmology.

[2]  Marcus Ang,et al.  Cost-effectiveness of Descemet's stripping endothelial keratoplasty versus penetrating keratoplasty. , 2013, Ophthalmology.

[3]  F. Grignolo,et al.  Pull-Through Insertion Technique for Descemet Stripping Automated Endothelial Keratoplasty (DSAEK): Graft Survival and Endothelial Cell Lossafter 1 Year in 100 Eyes , 2013 .

[4]  Roni M. Shtein,et al.  Comparative cost-effectiveness analysis of descemet stripping automated endothelial keratoplasty versus penetrating keratoplasty in the United States. , 2013, American journal of ophthalmology.

[5]  Salman N. Khan,et al.  An Overview on Performance Characteristics of Laser In-Situ Keratomileusis Using Lasers and Identification of Challenges , 2012 .

[6]  Marcus Ang,et al.  Endothelial cell loss and graft survival after Descemet's stripping automated endothelial keratoplasty and penetrating keratoplasty. , 2012, Ophthalmology.

[7]  Christopher G. Stoeger,et al.  The Endothelial Safety of Using a Gentian Violet Dry-Ink “S” Stamp for Precut Corneal Tissue , 2012, Cornea.

[8]  D. Tan,et al.  Endothelial keratoplasty: a revolution in evolution. , 2012, Survey of ophthalmology.

[9]  Terry Kim,et al.  Dislocation of the donor graft to the posterior segment in descemet stripping automated endothelial keratoplasty. , 2012, American journal of ophthalmology.

[10]  Margaret A. Greven,et al.  Small-Incision Descemet Stripping Automated Endothelial Keratoplasty: A Comparison of Small-Incision Tissue Injector and Forceps Techniques , 2012, Cornea.

[11]  K. Sugiyama,et al.  Clinical evaluation of a new donor graft inserter for Descemet's stripping automated endothelial keratoplasty. , 2012, Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye.

[12]  A. Al-shehri,et al.  Histopathological findings of failed grafts following Descemet's stripping automated endothelial keratoplasty (DSAEK). , 2012, Saudi journal of ophthalmology : official journal of the Saudi Ophthalmological Society.

[13]  Vinod Gangwani,et al.  A prospective study comparing EndoGlide and Busin glide insertion techniques in descemet stripping endothelial keratoplasty. , 2012, American journal of ophthalmology.

[14]  A. Slomovic,et al.  Evolving surgical techniques of and indications for corneal transplantation in Ontario from 2000 to 2009. , 2011, Canadian journal of ophthalmology. Journal canadien d'ophtalmologie.

[15]  稗田 牧,et al.  Descemet's Stripping Automated Endothelial Keratoplasty 術後における角膜内皮細胞密度の変化と影響因子の検討 , 2011 .

[16]  David A. Price,et al.  Descemet's stripping endothelial keratoplasty five-year graft survival and endothelial cell loss. , 2011, Ophthalmology.

[17]  K. Goins,et al.  Retrospective Review of Graft Dislocation Rate Associated With Descemet Stripping Automated Endothelial Keratoplasty After Primary Failed Penetrating Keratoplasty , 2011, Cornea.

[18]  J. Mehta,et al.  Descemet stripping automated endothelial keratoplasty with a graft insertion device: surgical technique and early clinical results. , 2011, American journal of ophthalmology.

[19]  K. Walter,et al.  A Safe and Convenient Method of Inserting and Controlling Donor Tissue During Endothelial Keratoplasty , 2011 .

[20]  M. Terry,et al.  Endothelial keratoplasty: the relationship between donor tissue storage time and donor endothelial survival. , 2011, Ophthalmology.

[21]  M. Terry,et al.  Peripheral Endothelial Cell Damage After Trephination of Donor Tissue , 2009, Cornea.

[22]  A. Kuo,et al.  Air bubble-associated endothelial trauma in descemet stripping automated endothelial keratoplasty. , 2009, American journal of ophthalmology.

[23]  M. Terry,et al.  Endothelial keratoplasty: vision, endothelial survival, and complications in a comparative case series of fellows vs attending surgeons. , 2009, American journal of ophthalmology.

[24]  I. Bahar,et al.  Retrospective Contralateral Study Comparing Descemet Stripping Automated Endothelial Keratoplasty With Penetrating Keratoplasty , 2009, Cornea.

[25]  T. Ide Descemet’s stripping automated endothelial keratoplasty injecting device , 2009 .

[26]  I. Bahar,et al.  Busin Guide vs Forceps for the Insertion of the Donor Lenticule in Descemet Stripping Automated Endothelial Keratoplasty. , 2009, American journal of ophthalmology.

[27]  Christopher G. Stoeger,et al.  Endothelial Keratoplasty: The Influence of Insertion Techniques and Incision Size on Donor Endothelial Survival , 2009, Cornea.

[28]  J. K. Lee,et al.  Descemet's Stripping Automated Endothelial Keratoplasty - A Review , 2009 .

[29]  V. Scorcia,et al.  A modified technique for descemet membrane stripping automated endothelial keratoplasty to minimize endothelial cell loss. , 2008, Archives of ophthalmology.

[30]  M. Terry,et al.  Descemet-Stripping Automated Endothelial Keratoplasty: Six-month Results in a Prospective Study of 100 Eyes , 2008, Cornea.

[31]  G. Kymionis,et al.  Descemet-stripping Automated Endothelial Keratoplasty (DSAEK): Effect of Nontoxic Gentian Violet Marking Pen on DSAEK Donor Tissue Viability by Using Vital Dye Assay , 2008, Cornea.

[32]  F. Price,et al.  Endothelial cell loss after descemet stripping with endothelial keratoplasty influencing factors and 2-year trend. , 2008, Ophthalmology.

[33]  C. Macaluso Closed-chamber pulling-injection system for donor graft insertion in endothelial keratoplasty. , 2008, Journal of cataract and refractive surgery.

[34]  V. Perez,et al.  Descemet-Stripping Automated Endothelial Keratoplasty: Effect of Inserting Forceps on DSAEK Donor Tissue Viability by Using an In Vitro Delivery Model and Vital Dye Assay , 2007, Cornea.

[35]  D. Covert,et al.  Early results of small-incision Descemet's stripping and automated endothelial keratoplasty. , 2007, Ophthalmology.

[36]  M. B. Goren The Eye Bank Association of America. , 2006, Comprehensive ophthalmology update.

[37]  Marianne O Price,et al.  Descemet's stripping with endothelial keratoplasty in 200 eyes: Early challenges and techniques to enhance donor adherence , 2006, Journal of cataract and refractive surgery.

[38]  Robert W. Thompson,et al.  Long-term graft survival after penetrating keratoplasty. , 2003, Ophthalmology.

[39]  N. Joyce Proliferative capacity of the corneal endothelium , 2003, Progress in Retinal and Eye Research.

[40]  S. Tuft,et al.  The corneal endothelium , 1990, Eye.

[41]  J. McLaren,et al.  Variations in human corneal endothelial cell morphology and permeability to fluorescein with age. , 1988, Experimental eye research.

[42]  R. Yee,et al.  Pump function of the human corneal endothelium. Effects of age and cornea guttata. , 1985, Ophthalmology.

[43]  R. Wilson,et al.  Effect of age on the endothelial cell count in the normal eye. , 1982, The British journal of ophthalmology.

[44]  C. Hanna,et al.  Endothelial cell population changes of human cornea during life. , 1978, Archives of ophthalmology.

[45]  E. Wolff The Anatomy of the Eye and Orbit , 1949, Nature.