Rapid NMR imaging of molecular self-diffusion using a modified CE-FAST sequence

Abstract This paper describes a new fast scan technique for magnetic resonance imaging of molecular self-diffusion. The method is based on a modified CE-FAST nuclear magnetic resonance sequence acquiring echo coherences of the steady-state free precession (SSFP) signal. The incorporation of an additional magnetic field gradient pulse into each repetition interval of the CE-FAST sequence results in an attenuation of the echo part of the SSFP signal due to diffusion. The extent of diffusion weighting may be varied by changing the duration or strength of the gradient pulse as well as the diffusion time here given by the repetition time. A series of diffusion-weighted images allows the calculation of local diffusion coefficients. 1H NMR imaging experiments on phantoms have been carried out using a 40 cm bore 2.35 T Bruker system.

[1]  Diffusion measurements by microscopic NMR imaging , 1988 .

[2]  I. Young,et al.  Variations in slice shape and absorption as artifacts in the determination of tissue parameters in NMR imaging , 1985, Magnetic resonance in medicine.

[3]  Jens Frahm,et al.  Self-diffusion NMR imaging using stimulated echoes , 1985 .

[4]  Jens Frahm,et al.  Transverse coherence in rapid FLASH NMR imaging , 1987 .

[5]  D. Woessner Effects of Diffusion in Nuclear Magnetic Resonance Spin-Echo Experiments , 1961 .

[6]  James M. Ortega,et al.  Iterative solution of nonlinear equations in several variables , 2014, Computer science and applied mathematics.

[7]  J. E. Tanner Use of the Stimulated Echo in NMR Diffusion Studies , 1970 .

[8]  M C Bushell,et al.  PRELIMINARY COMMUNICATION: The spatial mapping of translational diffusion coefficients by the NMR imaging technique , 1985 .

[9]  NMR imaging of restricted diffusion , 1987 .

[10]  R L Ehman,et al.  Translational molecular self-diffusion in magnetic resonance imaging. II. Measurement of the self-diffusion coefficient. , 1984, Investigative radiology.

[11]  J. E. Tanner,et al.  Spin diffusion measurements : spin echoes in the presence of a time-dependent field gradient , 1965 .

[12]  M. Gyngell,et al.  The application of steady-state free precession in rapid 2DFT NMR imaging: FAST and CE-FAST sequences. , 1988, Magnetic resonance imaging.

[13]  Slice‐shape artifact changes with precession angle in rapid MR imaging , 1987, Magnetic resonance in medicine.

[14]  Richard R. Ernst,et al.  Diffusion and field‐gradient effects in NMR Fourier spectroscopy , 1974 .

[15]  Slice selection and T1 contrast in FLASH NMR imaging , 1988 .