Uncertainty estimation in intensity-modulated radiotherapy absolute dosimetry verification.
暂无分享,去创建一个
Marta Paiusco | Roberto Capote | Antonio Leal | Javier Pena | Juan Ignacio Lagares | Francisco Sánchez-Doblado | Bernhard Rhein | Günther H Hartmann | B. Rhein | G. Hartmann | M. Paiusco | F. Sánchez-Doblado | J. Pena | R. Capote | A. Leal | J. Lagares
[1] I. Kawrakow. Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version. , 2000, Medical physics.
[2] F. Sánchez-Doblado,et al. Ionization chamber dosimetry of small photon fields: a Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams. , 2003, Physics in medicine and biology.
[3] J. Dempsey,et al. Quantitative dosimetric verification of an IMRT planning and delivery system. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.
[4] W. Neve,et al. Diamond detector measurements near simulated air channels for narrow photon beams. , 1999 .
[5] P. Andreo,et al. Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water , 2001 .
[6] G. Hartmann,et al. Micro ionization chamber dosimetry in IMRT verification: clinical implications of dosimetric errors in the PTV. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.
[7] C. Ma,et al. BEAM: a Monte Carlo code to simulate radiotherapy treatment units. , 1995, Medical physics.
[8] T Pawlicki,et al. Monte Carlo simulation for MLC-based intensity-modulated radiotherapy. , 2001, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.
[9] G. Hartmann,et al. An EGSnrc Monte Carlo study of the microionization chamber for reference dosimetry of narrow irregular IMRT beamlets. , 2004, Medical physics.
[10] F. H. Attix,et al. A theory of cavity ionization. , 1955, Radiation research.
[11] Josep Sempau,et al. Electron beam quality correction factors for plane-parallel ionization chambers: Monte Carlo calculations using the PENELOPE system. , 2004, Physics in medicine and biology.
[12] R Mohan,et al. A Monte Carlo model of photon beams used in radiation therapy. , 1995, Medical physics.
[13] I. Kawrakow,et al. Large efficiency improvements in BEAMnrc using directional bremsstrahlung splitting. , 2004, Medical physics.
[14] James A. Purdy,et al. Intensity-modulated radiotherapy: current status and issues of interest. , 2001, International journal of radiation oncology, biology, physics.
[15] L Chen,et al. Monitor unit calculation for Monte Carlo treatment planning , 2004, Physics in medicine and biology.
[16] R. Mohan,et al. A method for photon beam Monte Carlo multileaf collimator particle transport. , 2002, Physics in medicine and biology.
[17] J. Seuntjens,et al. Ionization chamber-based reference dosimetry of intensity modulated radiation beams. , 2004, Medical physics.
[18] T LoSasso,et al. Dosimetric verification of intensity-modulated fields. , 1996, Medical physics.
[19] A Piermattei,et al. PTW-diamond detector: dose rate and particle type dependence. , 2000, Medical physics.
[20] Monte Carlo dose verification for intensity-modulated arc therapy. , 2001, Physics in medicine and biology.
[21] J. Seuntjens,et al. Physical aspects of dynamic stereotactic radiosurgery with very small photon beams (1.5 and 3 mm in diameter). , 2003, Medical physics.
[22] C. De Wagter,et al. The value of the PinPoint ion chamber for characterization of small field segments used in intensity-modulated radiotherapy. , 2000, Physics in medicine and biology.
[23] Antonio Leal,et al. Routine IMRT verification by means of an automated Monte Carlo simulation system. , 2003, International journal of radiation oncology, biology, physics.
[24] C C Ling,et al. Relative profile and dose verification of intensity-modulated radiation therapy. , 2000, International journal of radiation oncology, biology, physics.
[25] Frank Verhaegen,et al. Evaluation of the EGSnrc Monte Carlo code for interface dosimetry near high-Z media exposed to kilovolt and 60Co photons. , 2002, Physics in medicine and biology.
[26] G. Hartmann,et al. Microionization chamber for reference dosimetry in IMRT verification: clinical implications on OAR dosimetric errors , 2005, Physics in medicine and biology.