Removal of Temperature and Earth's Field Effects of a Magnetoelastic pH Sensor

Magnetoelastic sensors are widely used for chemical and biological monitoring including measurement of pH, glucose, carbon dioxide, and Escherichia coli by applying a mass- or elasticity-changing coating that shifts the sensor's resonant frequency in response to the target analytes. However, the sensor's resonant frequency also varies with the ambient temperature and earth's magnetic fields, reducing the accuracy and reliability of the measurements. This paper presents a technique to eliminate the effects of temperature and earth's magnetic field on the magnetoelastic sensor by detecting the change in its higher order harmonic magnetic fields, which are generated by the sensor when excited by a low frequency magnetic field. The higher order harmonic response of the magnetoelastic sensor is a function of temperature and DC field but remains unaffected by the mass/elasticity change from the chemical or biological responsive coating, thus allowing the calibration of both interfering quantities. This paper illustrates the application of this technique on a magnetoelastic pH sensor, where the results show the calibrated measurements are independent from the ambient temperature and DC magnetic fields such as the earth's field.

[1]  K. Shankar,et al.  Quantification of multiple bioagents with wireless, remote-query magnetoelastic microsensors , 2006, IEEE Sensors Journal.

[2]  P. Ruuskanen,et al.  Moduli of elasticity of the Fe72.5Cu1Nb4Si13.5B9 amorphous alloy , 2003 .

[3]  Craig A. Grimes,et al.  Magnetic field tuning of the frequency–temperature response of a magnetoelastic sensor , 2002 .

[4]  Keat G Ong,et al.  Tracking the harmonic response of magnetically-soft sensors for wireless temperature, stress, and corrosive monitoring. , 2002, Sensors and actuators. A, Physical.

[5]  Craig A. Grimes,et al.  Higher-order harmonics of a magnetically soft sensor: Application to remote query temperature measurement , 2002 .

[6]  Craig A. Grimes,et al.  A salt-independent pH sensor , 2001 .

[7]  Craig A. Grimes,et al.  Magnetism-Based Remote Query Glucose Sensors , 2001 .

[8]  C A Grimes,et al.  A wireless, remote query ammonia sensor. , 2001, Sensors and actuators. B, Chemical.

[9]  Craig A. Grimes,et al.  Magnetism-based sensors , 2001, SPIE Optics + Photonics.

[10]  Craig A. Grimes,et al.  A wireless magnetoelastic micro-sensor array for simultaneous measurement of temperature and pressure , 2001 .

[11]  Craig A. Grimes,et al.  The frequency response of magnetoelastic sensors to stress and atmospheric pressure , 2000 .

[12]  C. Grimes,et al.  A remote query magnetoelastic pH sensor. , 2000, Sensors and actuators. B, Chemical.

[13]  Craig A. Grimes,et al.  Simultaneous measurement of liquid density and viscosity using remote query magnetoelastic sensors , 2000 .

[14]  C A Grimes,et al.  Remote query measurement of pressure, fluid-flow velocity, and humidity using magnetoelastic thick-film sensors. , 2000, Sensors and actuators. A, Physical.

[15]  Craig A. Grimes,et al.  Magnetoacoustic remote query temperature and humidity sensors , 2000 .

[16]  Craig A. Grimes,et al.  Remote query fluid-flow velocity measurement using magnetoelastic thick-film sensors (invited) , 2000 .

[17]  C A Grimes,et al.  A wireless, remote query magnetoelastic CO2 sensor. , 2000, Journal of environmental monitoring : JEM.

[18]  In Wireless , 2022 .