Supply Chain Operations Reference model for U.S. based powder bed metal additive manufacturing processes

This paper focuses on modeling the supply chain of an additively manufactured, uniquely customized Total Hip Replacement implant. It explores how the supply chain could be modeled for hip components which are customized for individual patients and produced using additive manufacturing processes. The concept of the SCOR (Supply Chain Operations Reference) model is used to create a formal model of this system. The SCOR model is used to compare the traditional and the AM supply chain on the basis of different performance metrics. The formal supply chain model is used to extract operational activities so that a computer simulation model of the system can be developed. The simulation is used to model system performance so that bottleneck operations can be identified and source needs determined along with a sensitivity analysis to analyze how change in times and resources affect production quantities.

[1]  Frederik L. Giesel,et al.  3D printing based on imaging data: review of medical applications , 2010, International Journal of Computer Assisted Radiology and Surgery.

[2]  R Richards,et al.  A review of rapid prototyped surgical guides for patient-specific total knee replacement. , 2012, The Journal of bone and joint surgery. British volume.

[3]  James C. Robinson,et al.  Variability in costs associated with total hip and knee replacement implants. , 2012, The Journal of bone and joint surgery. American volume.

[4]  Richard A. Wysk,et al.  Automatic simulation model generation for simulation-based, real-time shop floor control , 2001, Comput. Ind..

[5]  Leon F. McGinnis,et al.  Towards automated access to supply chain analyses , 2014 .

[6]  Mohammed Alzahrani Supply Chain Operations Reference , 2016 .

[7]  George A. Brown,et al.  Rapid Prototyping: The Future of Trauma Surgery? , 2003, The Journal of bone and joint surgery. American volume.

[8]  R. Maniar,et al.  Patient specific implants: scope for the future , 2014, Current Reviews in Musculoskeletal Medicine.

[9]  Marco Viceconti,et al.  HIDE: a new hybrid environment for the design of custom-made hip prosthesis , 2001, Comput. Methods Programs Biomed..

[10]  Syed H. Masood,et al.  Evaluation and Validation of the Shape Accuracy of FDM Fabricated Medical Models , 2009 .

[11]  J. Charnley,et al.  Radiological demarcation of cemented sockets in total hip replacement. , 1976, Clinical orthopaedics and related research.

[12]  G. Booysen,et al.  Using RP to promote collaborative design of customised medical implants , 2007 .

[13]  F. Al-Shamali,et al.  Author Biographies. , 2015, Journal of social work in disability & rehabilitation.

[14]  Fredrik Persson,et al.  The development of a dynamic supply chain analysis tool—Integration of SCOR and discrete event simulation , 2009 .

[15]  Yasser A. Hosni,et al.  Design and Manufacturing of Customized Implants , 2002 .

[16]  Yongtae Jun,et al.  Design of patient-specific hip implants based on the 3D geometry of the human femur , 2010, Adv. Eng. Softw..

[17]  failureS Of TOTal hip replaceMenT : a pOpulaTiOn-baSed perSpecTive , 2007 .

[18]  Elena Losina,et al.  Rates and Outcomes of Primary and Revision Total Hip Replacement in the United States Medicare Population , 2003, The Journal of bone and joint surgery. American volume.

[19]  Y. Toshev,et al.  MEDICAL RAPID PROTOTYPING APPLICATIONS AND METHODS , 2005 .