Joint strength of laser-welded titanium.

OBJECTIVE The objective of this study was to examine the joint strength of titanium laser-welding using several levels of laser output energy [current (A)]. METHODS Cast titanium plates (0.5 x 3.0 x 40 and 1.0 x 3.0 x 40 mm(3)) were prepared and perpendicularly cut at the center of the plate. After the cut halves were fixed in a jig, they were laser-welded using a Nd: YAG laser at several levels of output energy in increments of 30A from 180 to 300A. The penetration depths of laser to titanium were measured under various conditions for output energy, pulse duration, and spot diameter to determine the appropriate conditions for these parameters. Based on the correlation between the results obtained for penetration depth and the size of the specimens (thickness: 0.5 and 1.0 mm, width: 3.0 mm), the pulse duration and spot diameter employed in this study were 10 ms and 1.0 mm, respectively. Three laser pulses (spot diameter: 1.0 mm) were applied from one side to weld the entire joint width (3.0 mm) of the specimens. Uncut specimens served as the non-welded control specimens. Tensile testing was conducted at a crosshead speed of 2 mm/min and a gage length of 10 mm. The breaking force (N) was recorded, and the data (n=5) were statistically analyzed. RESULTS For the 0.5 mm thick specimens, the breaking force of the specimens laser-welded at currents of 240, 270, and 300A were not statistically (P>0.05) different from the non-welded control specimens. There were no significant differences in breaking force among the 1.0mm thick specimens laser-welded at currents of 270 and 300A, and the non-welded control specimens. SIGNIFICANCE Under appropriate conditions, joint strengths similar to the strength of the non-welded parent metal were achieved.

[1]  B. Kasemo Biocompatibility of titanium implants: surface science aspects. , 1983, The Journal of prosthetic dentistry.

[2]  M. Bergman,et al.  Laser welding of titanium in dentistry. , 1988, Acta odontologica Scandinavica.

[3]  J. Chai,et al.  Mechanical properties of titanium connectors. , 1996, The International journal of prosthodontics.

[4]  D. Williams,et al.  Biocompatibility of clinical implant materials , 1981 .

[5]  T. Okabe,et al.  Tensile strength of soldered gold alloy joints. , 1997, The Journal of prosthetic dentistry (Print).

[6]  T. Kodama [Study on biocompatibility of titanium alloys]. , 1989, Kokubyo Gakkai zasshi. The Journal of the Stomatological Society, Japan.

[7]  E. Dootz,et al.  Mechanical properties of laser-welded cast and wrought titanium. , 1995, The Journal of prosthetic dentistry.

[8]  T. Chai,et al.  Mechanical properties of laser-welded cast titanium joints under different conditions. , 1998, The Journal of prosthetic dentistry.

[9]  T. Yamagishi,et al.  Mechanical properties of laser welds of titanium in dentistry by pulsed Nd:YAG laser apparatus. , 1993, The Journal of prosthetic dentistry.

[10]  R. Wang,et al.  Thermal modeling of laser welding for titanium dental restorations. , 1998, The Journal of prosthetic dentistry.

[11]  G. Welsch,et al.  Joining titanium materials with tungsten inert gas welding, laser welding, and infrared brazing. , 1995, The Journal of prosthetic dentistry.

[12]  K. Böning,et al.  Studies on laser- and plasma-welded titanium. , 1993, Dental materials : official publication of the Academy of Dental Materials.