Life-Threatening Arrhythmia Verification in ICU Patients Using the Joint Cardiovascular Dynamical Model and a Bayesian Filter

In this paper, a novel nonlinear joint dynamical model is presented, which is based on a set of coupled ordinary differential equations of motion and a Gaussian mixture model representation of pulsatile cardiovascular (CV) signals. In the proposed framework, the joint interdependences of CV signals are incorporated by assuming a unique angular frequency that controls the limit cycle of the heart rate. Moreover, the time consequence of CV signals is controlled by the same phase parameter that results in the space dimensionality reduction. These joint equations together with linear assignments to observation are further used in the Kalman filter structure for estimation and tracking. Moreover, we propose a measure of signal fidelity by monitoring the covariance matrix of the innovation signals throughout the filtering procedure. Five categories of life-threatening arrhythmias were verified by simultaneously tracking the signal fidelity and the polar representation of the CV signal estimations. We analyzed data from Physiobank multiparameter databases (MIMIC I and II). Performance evaluation results demonstrated that the sensitivity of the detection ranges over 93.50% and 100.00%. In particular, the addition of more CV signals improved the positive predictivity of the proposed method to 99.27% for the total arrhythmic types. The method was also used for false arrhythmia suppression issued by ICU monitors, with an overall false suppression rate reduced from 42.3% to 9.9%. In addition, false critical ECG arrhythmia alarm rates were found to be, on average, 42.3%, with individual rates varying between 16.7% and 86.5%. The results illustrate that the method can contribute to, and enhance the performance of clinical life-threatening arrhythmia detection.

[1]  R. G. Mark,et al.  Reduction of false arterial blood pressure alarms using signal quality assessement and relationships between the electrocardiogram and arterial blood pressure , 2004, Medical and Biological Engineering and Computing.

[2]  C. Jutten,et al.  Filtering noisy ECG signals using the extended kalman filter based on a modified dynamic ECG model , 2005, Computers in Cardiology, 2005.

[3]  A Deshmane,et al.  False arrhythmia alarm suppression using ECG, ABP, and photoplethysmogram , 2009 .

[4]  S. Haykin Kalman Filtering and Neural Networks , 2001 .

[5]  Mohammad Bagher Shamsollahi,et al.  Robust Detection of Premature Ventricular Contractions Using a Wave-Based Bayesian Framework , 2010, IEEE Transactions on Biomedical Engineering.

[6]  Mohinder S. Grewal,et al.  Global Positioning Systems, Inertial Navigation, and Integration , 2000 .

[7]  Patrick E. McSharry,et al.  A dynamical model for generating synthetic electrocardiogram signals , 2003, IEEE Transactions on Biomedical Engineering.

[8]  F. Benito,et al.  ECG spectral and morphological parameters reviewed and updated to detect adult and paediatric life-threatening arrhythmia , 2010, Physiological measurement.

[9]  Rudolph van der Merwe,et al.  The Unscented Kalman Filter , 2002 .

[10]  N. Thakor,et al.  Ventricular tachycardia and fibrillation detection by a sequential hypothesis testing algorithm , 1990, IEEE Transactions on Biomedical Engineering.

[11]  D. Dubin Rapid Interpretation of EKG's , 1977 .

[12]  Dan Simon,et al.  Optimal State Estimation: Kalman, H∞, and Nonlinear Approaches , 2006 .

[13]  G. Moody,et al.  A database to support development and evaluation of intelligent intensive care monitoring , 1996, Computers in Cardiology 1996.

[14]  Sailes K. Sengijpta Fundamentals of Statistical Signal Processing: Estimation Theory , 1995 .

[15]  R G Mark,et al.  MIMIC II: a massive temporal ICU patient database to support research in intelligent patient monitoring , 2002, Computers in Cardiology.

[16]  Mohammed Saeed,et al.  Reducing false alarm rates for critical arrhythmias using the arterial blood pressure waveform , 2008, J. Biomed. Informatics.

[17]  Xu-Sheng Zhang,et al.  Detecting ventricular tachycardia and fibrillation by complexity measure , 1999, IEEE Transactions on Biomedical Engineering.

[18]  C. Jutten,et al.  Filtering Electrocardiogram Signals Using the Extended Kalman Filter , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[19]  Methods to Assess Baroreflex Sensitivity as a Measure of the Activity of the Autonomic Nervous System , 2000 .

[20]  S Barro,et al.  Algorithmic sequential decision-making in the frequency domain for life threatening ventricular arrhythmias and imitative artefacts: a diagnostic system. , 1989, Journal of biomedical engineering.

[21]  J. Taylor,et al.  Short‐term cardiovascular oscillations in man: measuring and modelling the physiologies , 2002, The Journal of physiology.

[22]  M. Kern Hemodynamic Rounds: Interpretation of Cardiac Pathophysiology from Pressure Waveform Analysis , 1992 .

[23]  R I Kitney,et al.  Transient interactions between blood pressure, respiration and heart rate in man. , 1985, Journal of biomedical engineering.

[24]  R.G. Mark,et al.  A signal abnormality index for arterial blood pressure waveforms , 2006, 2006 Computers in Cardiology.

[25]  P. Djurić,et al.  Particle filtering , 2003, IEEE Signal Process. Mag..

[26]  Arthur Gelb,et al.  Applied Optimal Estimation , 1974 .

[27]  Giuseppe Baselli,et al.  Biomedical signal processing and modeling in cardiovascular systems. , 2002, Critical reviews in biomedical engineering.

[28]  Richard E. Kerber,et al.  Automatic External Defibrillators for Public Access Defibrillation: Recommendations for Specifying and Reporting Arrhythmia Analysis Algorithm Performance, Incorporating New Waveforms, and Enhancing Safety , 1997, Biomedical instrumentation & technology.

[29]  Christian Jutten,et al.  A Nonlinear Bayesian Filtering Framework for ECG Denoising , 2007, IEEE Transactions on Biomedical Engineering.

[30]  James McNames,et al.  Statistical Modeling of Cardiovascular Signals and Parameter Estimation Based on the Extended Kalman Filter , 2008, IEEE Transactions on Biomedical Engineering.

[31]  James Xin Sun,et al.  Cardiac output estimation using arterial blood pressure waveforms , 2006 .

[32]  R J Cohen,et al.  Beat to beat variability in cardiovascular variables: noise or music? , 1989, Journal of the American College of Cardiology.