Abstract One aspect of the AP1000 ® 1 reactor design is the reduction in the number of major components and simplification in manufacturing. One design change relative to current Westinghouse reactors of similar size is the reduction in the number of reactor vessel outlet nozzles/hot legs leaving the upper plenum from three to two. With regard to fuel performance, this design difference creates a different flow field in the AP1000 reactor vessel upper plenum (the region above the core). The flow exiting core and entering the upper plenum must turn 90°, flow laterally through the upper plenum around support structures, and exit through one of the two outlet nozzles. While the flow in the top of the core is mostly axial, there is some lateral flow component as the core flow reacts to the flow field and pressure distribution in the upper plenum. The pressure distribution in the upper plenum varies laterally depending upon various factors including the proximity to the outlet nozzles. To determine how the lateral flow in the top of the AP1000 core compares to current Westinghouse reactors, a computational fluid dynamics (CFD) model of the flow in the upper portion of the AP1000 reactor vessel including the top region of the core, the upper plenum, the reactor vessel outlet nozzles, and a portion of the hot legs was created. Due to geometric symmetry, the computational domain was reduced to a quarter (from the top view) that includes ¼ of the top of the core, ¼ of the upper plenum, and ½ of an outlet nozzle. Results from this model include predicted velocity fields and pressure distributions throughout the model domain. The flow patterns inside and around guide tubes clearly demonstrate the influence of lateral flow due to the presence of the outlet nozzles. From these results, comparisons of AP1000 flow versus current Westinghouse plants were performed. Field performance information from current Westinghouse plants will be shown to demonstrate an experience base of acceptable core lateral flows. From this experience base and the AP1000 CFD results, acceptability of the AP1000 upper plenum design on the fuel performance of the AP1000 fuel design will be demonstrated.
[1]
Kun Yuan,et al.
CFD analysis of PWR core top and reactor vessel upper plenum internal subdomain models
,
2011
.
[2]
Kun Yuan,et al.
CFD Analysis of PWR Core Top Region: Top Fuel Assembly and Top Nozzle Regions
,
2010
.
[3]
Chung-Yun Wu,et al.
CFD analysis for full vessel upper plenum in Maanshan Nuclear Power Plant
,
2012
.
[4]
T. Shih,et al.
A New K-epsilon Eddy Viscosity Model for High Reynolds Number Turbulent Flows: Model Development and Validation
,
1994
.
[5]
Wei Shyy,et al.
EFFECTS OF OPEN BOUNDARY ON INCOMPRESSIBLE NAVIER-STOKES FLOW COMPUTATION: NUMERICAL EXPERIMENTS
,
1987
.
[6]
Ray Sumit.
Robustness in the design and manufacture of the AP1000 fuel assembly
,
2009
.
[7]
Wei Shyy,et al.
Numerical outflow boundary condition for Navier-Stokes flow calculations by a line iterative method
,
1985
.
[8]
Michael E. Conner,et al.
Benchmarking Computational Fluid Dynamics for Application to PWR Fuel
,
2002
.
[9]
F. Archambeau,et al.
Computational fluid dynamic analysis of a guide tube in a PWR
,
2000
.