Theoretical analysis of a combined power and ejector refrigeration cycle using zeotropic mixture

A theoretical study on a combined power and ejector refrigeration cycle using zeotropic mixture isobutane/pentane is carried out. The performances of different mixture compositions are compared. An exergy analysis is conducted for the cycle. The result reveals that most exergy destruction happens in the ejector, where more than 40% exergy is lost. The heat exchange in generator causes the second largest exergy loss, larger than 28%. As the mass fraction of isobutane changes ranges from 100% to 0%, the relative exergy destruction of each component is also changing. And mixture isobutane/pentane (50/50) has the maximum exergy efficiency of 7.83%. The parametric analysis of generator temperature, condenser temperature and evaporator temperature for all the mixtures shows that, all these three thermodynamic parameters have a strong effect on the cycle performance.

[1]  Jarosław Karwacki,et al.  Experimental investigations of low-temperature driven ejection refrigeration cycle operating with isobutane , 2014 .

[2]  Li Zhao,et al.  Thermodynamic analysis of organic Rankine cycle using zeotropic mixtures , 2014 .

[3]  Yiping Dai,et al.  A theoretical study on a novel combined power and ejector refrigeration cycle , 2009 .

[4]  Mohammad Mehdi Rashidi,et al.  Analysis of a combined power and ejector-refrigeration cycle using low temperature heat , 2013 .

[5]  Li Zhao,et al.  Analysis of zeotropic mixtures used in low-temperature solar Rankine cycles for power generation , 2009 .

[6]  Bin-Juine Huang,et al.  A 1-D analysis of ejector performance , 1999 .

[7]  Yiping Dai,et al.  Exergy analysis, parametric analysis and optimization for a novel combined power and ejector refrigeration cycle , 2009 .

[8]  Björn Palm,et al.  Parametric analysis of ejector working characteristics in the refrigeration system , 2014 .

[9]  Hongguang Jin,et al.  Thermodynamic analysis of a novel absorption power/cooling combined-cycle , 2006 .

[10]  K. Cizungu,et al.  Performance comparison of vapour jet refrigeration system with environment friendly working fluids , 2001 .

[11]  D. Goswami,et al.  A combined power/cooling cycle , 2000 .

[12]  Xianbiao Bu,et al.  Performance characteristics of R1234yf ejector-expansion refrigeration cycle , 2014 .

[13]  Yiping Dai,et al.  Parametric analysis and optimization for a combined power and refrigeration cycle , 2008 .

[14]  Lijun Yu,et al.  Effects of evaporating temperature and internal heat exchanger on organic Rankine cycle , 2011 .

[15]  H. Kursad Ersoy,et al.  Preliminary experimental results on the R134a refrigeration system using a two-phase ejector as an expander , 2014 .